M SERIES M150 | M175 | M250 POOL & SPA PUMP INSTALLATION AND OPERATION MANUAL
[email protected]
oasisaquatics.com.au
5
DIMENSIONS
INSTALLATION INSTRUCTIONS
Location
The pump should be located as close to the water as practicable and mounted on a firm base in
a well-drained position, high enough to prevent any flooding
. It is the installer’s
/owners
responsibility to locate the pump so that it can be accessed for service and maintenance. The
rear fan shroud should be installed at a minimum distance of 100 mm away from any walls or
obstructions. This is to allow adequate air flow from the fan to cool the motor. Overheating due
to a lack of cooling voids warranty.
WEATHER PROTECTION
It is recommended that the pump be protected from the weather.
Enclosures should be ventilated to allow a free flow of air for the fan cooled motor.
POWER CONNECTION
OASIS pool and spa pumps are suitable for connection to a nominal 240-volt 50Hz power supply.
The motor is equipped with a flex and 3-pin plug. If a power outlet is not available within 2 meters of
the pump, a 3-pin power point in a safe, dry place may need to be provided by an electrician.
Note:
•
Pumps must be either
o
Supplied by an isolating transformer, or
o
Supplied through a residual current device (RCD) with a rated residual operating current
not exceeding
30mA.
•
Extension cords are unsafe around pools and must be avoided.
•
If the supply cord of this product is damaged the dealer or manufacturer must replace it,
with genuine OASIS pool and spa pump spares.
•
Water temperature is not to exceed 45 degrees
670
V390
@
700