background image

 

M SERIES M150 | M175 | M250 POOL & SPA PUMP INSTALLATION AND OPERATION MANUAL

 

 

[email protected] 
oasisaquatics.com.au 

4

 

 

INSTALLATION & OPERATING INSTRUCTIONS 

OASIS

’S POO

L AND SPA PUMP 

Congratulations  on  your  purchase  of  a  quality  product  from  the  OASIS  range  of  Pool  and  Spa 
Equipment.  You  will  be  pleased  with  the  many  years  of  reliable  and  efficient  performance  your 
OASIS pool and spa pump will deliver. 

OASIS  pool  and  spa  pumps  have  been  designed  to  circulate  swimming  pool  and  spa  water  in 
conditions set out in the Australian Standard for swimming pool water quality (AS 3633) 

OASIS designs  its  own  electric  motors  specifically 

for  its  pumps.  The  matched  motor  and  “p

ump 

weten

d” are designed 

to provide quiet operation and energy efficiency. 

OASIS

’S

  totally  enclosed  fan-

cooled  motor  incorporates  “thermal  cut

-

out”  overload  protection 

designed to protect the motor from overheating. 

Every OASIS pool and spa pump is thoroughly water tested against flow, pressure, voltage, current 
and mechanical performance parameters. OASIS

’S

 advanced pump technology provides reliable and 

efficient performance that lasts. 

OASIS pool and spa pump are designed with high flow and the head pressures are ideally suited for 
the modern pool or spa with extensive equipment. 

OASIS pool and spa pumps are designed to operate with most chlorinators, heaters and other pool 
equipment producing correct water flow and energy efficiency. 

 

FEATURES & BENEFITS  

 

Powerful high performance pumping delivers optimum flow rates & rapid priming 

 

Efficient flow for pool water & solar heating circulation. 

 

Computer-designed impeller and diffuser quickly corrects loss of water flow allowing a free 
flow of water offering whisper quiet, efficient performance. 

 

Easy to remove, see through strainer lid for easy removal of leaves 

 

Extra large strainer basket allows long intervals between cleaning. 

 

Continuous duty rated motor 

with an enclosed fan cooled motor protects against dirt, dust and

 

water for long life

 

 

 

Built-in thermal overload protects the motor against damage from overheating 

 

Every unit is pressure and performance tested in factory ensuring quality and reliability 

 

High performance Silicon Carbide mechanical seal, fitted for long life in salt & fresh water 

 

2m power lead with 10amp three-pin plug fitted 

 

Constructed of strong corrosion and U.V. resistant materials for long life 

 

On some models, built-in check valve reduces reverse flow of water through pump. 

 

Exceed electrical standards for installation in the specified pool zone 

 

A.B.S. quick connect couplings makes installation simple 

 

If required a drain plug enables pump casing to be drained for easy maintenance 

 

Limited 2 Year Warranty 

 See Warranty Information 

 

Summary of Contents for M Series

Page 1: ...OPERATION MANUAL M SERIES Pool Spa Pump M SERIES Pool Spa Pump M150 M175 M250 Head Office 62 Parkhurst Drive Knoxfield VIC 3180 T 03 9887 2131 New South Wales Unit 1 20 22 Foundry Road Seven Hills NSW...

Page 2: ...INSTALLATION AND OPERATION MANUAL info oasisaquatics com au oasisaquatics com au 2 PLEASE READ THESE INSTRUCTIONS BEFORE OPERATING Please pass these instructions on to the owner of this equipment MOD...

Page 3: ...e all wiring connections are clean and that all wiring and electrical equipment is in good condition Damaged wiring must be repaired or replaced by a qualified electrician as soon as damage is discove...

Page 4: ...ve equipment OASIS pool and spa pumps are designed to operate with most chlorinators heaters and other pool equipment producing correct water flow and energy efficiency FEATURES BENEFITS Powerful high...

Page 5: ...ON It is recommended that the pump be protected from the weather Enclosures should be ventilated to allow a free flow of air for the fan cooled motor POWER CONNECTION OASIS pool and spa pumps are suit...

Page 6: ...and may cause damage to the pump voiding warranty A straight length of pipe measuring no less than 300mm should be installed in front of the inlet of the pump allowing quieter and smoother operation...

Page 7: ...d indicates an air leak in the suction piping work which should be rectified to avoid pump damage 5 If water flow through the pump is continuously tedious to obtain at start up after cleaning the lint...

Page 8: ...w 1 Switch off pump 2 Unscrew the hair and lint pot strainer basket lid anti clockwise and remove 3 Remove the hair and lint pot strainer basket by lifting upwards from its housing 4 Empty the trapped...

Page 9: ...Customer Service Centre at the address indicated in this manual If the pump runs but there is no water flow or water flow is reduced the following condition may apply 1 The filter requires backwashing...

Page 10: ...pump is not intended for use by young children or infirm persons without supervision Ensure that young children are supervised at all times to ensure that they do not play with the pump COMMERCIAL INS...

Page 11: ...failure is due to any abuse misuse improper installation or accident or to any of the following Improper chemical balance in the water Incorrect power supply and or connection Water damage from extern...

Page 12: ...UAL info oasisaquatics com au oasisaquatics com au 12 A part of the group Victoria 62 Parkhurst Drive Knoxfield VIC 3180 Australia New South Wales Unit 1 20 22 Foundry Road Seven Hills NSW 2147 Austra...

Reviews: