10
- English -
Pos: 26 /Lampen/Wasserspieltechnik/Water-Trio/Quintet USA/Montage Water Trio-Quintet USA @ 10\mod_1235478587091_121.doc @ 60373 @
Installation
Attention! Dangerous electrical voltage.
Unit sections, connections and pond water could carry dangerous voltage if the electrical installation of the
unit is incorrectly performed.
Possible consequences:
Death or severe injury when touching unit sections, connections or in the event
of contact with the pond water.
Protective measures:
−
Install transformer and 12 V control box at a dry, splash-water protected place. Additionally protect the
12 V control box against sun radiation (max. 40 °C / 104 °F).
−
During operation, ensure that both the transformer and the 12 V control box are placed at a 2 m (6,6 ft)
safety distance from the bank
(D)
.
Pos: 27 /Alle Produkte/Überschriften/H1 Aufstellen @ 7\mod_1202907856718_121.doc @ 43934 @
Installation
Pos: 28 /Lampen/Wasserspieltechnik/Water-Trio/Quintet USA/Aufstellen Water Trio-Quintet USA @ 10\mod_1235479040540_121.doc @ 60400 @
Installing the Water Trio / Water Quintet (B, C)
:
Variant 1 (B)
:
−
Install the unit as horizontally as possible in the water on a firm ground.
−
The minimum water level must be just above the pumps
(8)
.
Variant 2 (C)
:
In the case of excessive water depth, the extension tubes
(6)
can be used to compensate. If not sufficient, select a
different suitable place of installation.
−
To open, release the nozzle holders
(9)
by slightly turning them at the housing top section
(10)
and remove.
−
Unscrew the LED light nozzle
(11)
.
−
Screw the extension tubes
(6)
between the LED light nozzles
(11)
and the pumps
(12)
.
−
Close the unit by placing the housing top section
(10)
on the LED light nozzles
(11)
and fasten using the nozzle
holders
(9)
.
−
Install the unit as horizontally as possible in the water on a firm ground.
−
The minimum water level must be just above the pumps
(8)
.
Note
: Ensure that the water inlet at the unit underside is not impaired!
Pos: 29 /Lampen/Wasserspieltechnik/Water-Trio/Quintet/Aufstellung Steuerungsbox und Trafo Water Trio/Quintet @ 8\mod_1219924083632_121.doc @ 51213 @
Installation of the 12 V control box (E, F):
Variant 1 (E)
:
−
Push the ground stake
(5)
fully into the ground at the desired position.
−
Slide the 12 V control box
(3)
onto the ground stake
(5)
.
Variant 2 (F)
:
−
Screw the 12 V control box
(3)
to the ground using 4 screws
(13)
(not included in our scope of delivery) through the
fastening slots
(14)
in the housing of the 12 V control box
(3)
.
Installation of the transformer (G)
:
Install the transformer
(2)
close to the 12 V control box
(3)
.
Note
: Ensure that the cables are routed strain relieved!
Pos: 30 /Alle Produkte/Überschriften/H1 Elektrische Installation @ 8\mod_1219935543509_121.doc @ 51295 @
Electrical installation
Pos: 31 /Lampen/Wasserspieltechnik/Water-Trio/Quintet/INS_Water Trio/Quintet @ 8\mod_1219738775961_121.doc @ 50919 @
'Connect Water Trio / Water Quintet to 12 V control box (G, H)
:
−
Plug the pump plugs
(18)
from Water Trio / Water Quintet and the LED light nozzle plugs
(20)
into the respective
sockets for the pump
(19)
and the LED light nozzles
(21)
of the 12 V control box
(3)
. Note the order of the plugs
(plugs are marked).
−
Insert the connection cable
(17)
of the transformer in the rear socket
(15)
of the 12 V control box
(3)
, then screw-
tighten the cable with the union nut
(16)
.
−
Fit the protection sleeve
(4)
over the 12 V control box
(3)
.
Pos: 32 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1631 @