12
- English -
Pos: 39 /Lampen/Wasserspieltechnik/Water-Jet Lightning USA/Handsender einlernen Water Jet Lightning USA @ 10\mod_1235557100548_121.doc @ 60755 @
The manual transmitter contained in the scope of delivery is already taught in to the 12 V control box. Each further
manual transmitter has to be newly taught in for the 12 V control box.
Manual transmitter teach-in (K)
The 12 V control box
(2)
is equipped with a teach-in button
(31)
to be able to carry out the manual transmitter teach-in.
−
Insert a pin
(32)
in the opening for the teach-in button
(31)
.
−
Actuate the teach-in button
(31)
using the pin
(32)
for approx. 1 sec.
−
Press any button of the manual transmitter for at least 1 sec.
Deleting the manual transmitter (K)
−
Actuate the teach-in button
(31)
using a pin
(32)
for at least 5 sec.
All manual transmitters saved in the 12 V control box
(2)
are deleted.
Note
: A maximum of 10 manual transmitters can be set to the receiver. The manual transmitter has a maximum range
of 80 m (260 ft). Obstacles between transmitter and receiver, a low battery in the manual transmitter, or electro-
magnetic radiation of electrical equipment will impair the range.
Pos: 40 /Alle Produkte/Überschriften/H1 Reinigung und Wartung @ 7\mod_1196625212761_121.doc @ 41469 @
Maintenance and cleaning
Pos: 41 /Lampen/Wasserspieltechnik/Water Jet Lightning/WAR_Reinigung und Wartung_Water-Jet-Lightning @ 8\mod_1221040256101_121.doc @ 52343 @
Prior to starting work on the units, disconnect the power plugs of all units in the water (J)!
Cleaning the Water Jet Lightning (N, O)
−
Separate the upper section
(34)
from the housing bottom section
(36)
with a slight twist, then remove together with
the O-ring
(35)
.
−
Remove the foam filter
(37)
and unscrew the LED unit
(38)
.
−
Clean all parts under running water using a soft brush.
−
Squeeze out the foam filter
(37)
several times under running water.
Cleaning the pump (D, P)
−
Loosen the union nut
(14)
at the Y distributor
(15)
.
−
Unscrew the reduction piece
(16)
from the pump
(4)
and remove the Y distributor
(15)
.
−
Pull the motor housing
(39)
out of the engagement holder of the plug-in filter
(40)
.
−
Remove the pump housing (41) with a slight turn, and remove the impeller
(42)
.
−
Clean all parts under running water using a soft brush.
Unit reassembly
(N, O, D, P)
−
Reassemble the units in the reverse order.
Pos: 42 /Lampen/Wasserspieltechnik/Water Jet Lightning/Batteriewechsel Handsender Water-Jet-Lightning @ 8\mod_1221040331102_121.doc @ 52369 @
Battery change in the manual transmitter (Q, R)
Improper treatment can lead to damage of the manual transmitter!
−
Touch an uncoated metal surface (e.g. radiator) to discharge static charges that could lead to damage to
the internal components of the manual transmitter!
−
Prevent the ingress of dirt and humidity into the manual transmitter!
−
Insert a screwdriver
(43)
into the lateral opening
(44)
of the manual transmitter.
−
Open the housing of the manual transmitter by slightly turning the screwdriver, then remove the housing bottom
section
(45)
.
−
Pull the battery
(46)
out of the holder
(47)
.
−
Push the new battery (type CR 2032) into the holder
(47)
. Ensure that the embossed side
(48)
of the battery points
upward.
Pos: 43 /Alle Produkte/Überschriften/H1 Lagern / Überwintern @ 7\mod_1196625251745_121.doc @ 41495 @
Storage/Over-wintering
Pos: 44 /Lampen/Wasserspieltechnik/Water Jet Lightning/Lagern und Überwintern Water Jet Lightning @ 8\mod_1221564068782_121.doc @ 52503 @
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the Water Jet Lightning frost-free, store the pump frost-free and immersed in a container filled with wa-
ter
(Figure S)
. Do not immerse the plug.
Pos: 45 /Alle Produkte/Überschriften/H1 Entsorgung @ 7\mod_1196625583904_121.doc @ 41547 @
Disposal
Pos: 46 /Alle Produkte/Entsorgung - gem. Bestimmungen @ 8\mod_1223247321369_121.doc @ 53910 @
Dispose of the unit in accordance with the national legal regulations.
Pos: 47 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1631 @