MAINTENANCE AND CLEANING
N O T E
Recommendation on regular cleaning:
•
Clean the unit as required but at least
twice per year.
•
Do not use aggressive cleaning agents
or chemical solutions as they could at-
tack the housing or impair the function
of the unit.
•
Recommended cleaning agent for re-
moving stubborn limescale deposits:
– Pump cleaning agent PumpClean
from OASE.
– Vinegar- and chlorine-free household
cleaning agent.
•
After cleaning, thoroughly rinse all parts
in clean water.
Cleaning the non-return valve
Sand can block the non-return valve of the
pump so that it cannot close properly. The
non-return valve has to be cleaned.
Prerequisite:
•
The pressure hose and adapter have
been dismantled.
ProMax Pressure Automatic 5500/5,
6000/8, Well Automatic 6000/8
How to proceed:
F
1. Remove the screws.
2. Carefully remove the cover.
– The ball of the vent valve will fall out.
Ensure that you do not lose the ball.
3. Pull out the non-return valve.
4. Thoroughly clean the non-return valve
with clean water.
5. Reassemble the parts in the reverse or-
der.
6. Prior to installing, allow the pump to
convey clear water for a few minutes
(e.g. in a basin) to completely remove
any sand residue.
ProMax Pressure Well Automatic
3000/15
How to proceed:
G
1. Use suitable locking ring pliers to re-
move the locking ring.
2. Pull out the non-return valve.
3. Thoroughly clean the non-return valve
with clean water.
4. Reassemble the parts in the reverse or-
der.
5. Prior to installing, allow the pump to
convey clear water for a few minutes
(e.g. in a basin) to completely remove
any sand residue.
WEAR PARTS
The following components are wear parts
and may only be replaced by the OASE
Service.
•
Impeller unit
Summary of Contents for ProMax Pressure Automatic 5500/5
Page 3: ...3 E POX0022 F G POX0089 POX0104...
Page 147: ...DE EN FR NL ES PT IT DA NO SV FI HU PL CS SK SL HR RO BG UK RU CN 147 BG 8 30 mA OASE...
Page 151: ...DE EN FR NL ES PT IT DA NO SV FI HU PL CS SK SL HR RO BG UK RU CN 151 3 5 bar 1...
Page 155: ...DE EN FR NL ES PT IT DA NO SV FI HU PL CS SK SL HR RO BG UK RU CN 155 UK 8 30 OASE...
Page 159: ...DE EN FR NL ES PT IT DA NO SV FI HU PL CS SK SL HR RO BG UK RU CN 159 flow control 3 5 1...
Page 162: ...162 ProMax Pressure Automatic 5500 5 6000 8 Well Automatic 3000 15 6000 8 OASE...
Page 164: ...164 ProMax Pressure Automatic 5500 5 6000 8 Well Automatic 3000 15 6000 8 RU 8 30 OASE...
Page 168: ...168 ProMax Pressure Automatic 5500 5 6000 8 Well Automatic 3000 15 6000 8 flow control 3 5 1...
Page 169: ...DE EN FR NL ES PT IT DA NO SV FI HU PL CS SK SL HR RO BG UK RU CN 169 OASE OASE Oase...
Page 179: ...179...
Page 180: ...36106 01 20...