![background image](http://html1.mh-extra.com/html/oase/promax-garden-classic-3000/promax-garden-classic-3000_operating-instructions-manual_3523584012.webp)
12
ProMax Garden Classic 3000/4500
How to proceed:
C
1. Unscrew the water infill screw.
2. Pour water into the infill opening until it
overflows.
3. Screw in the water infill screw again.
4. Open the pressure line if necessary.
5. Insert the power plug into the socket.
6. Switch on the pump.
– The pump starts pumping immedi-
ately. The emerging water still con-
tains some air.
Shutting down the pump
How to proceed:
1. Switch off the pump
2. Disconnect the power plug.
3. Depressurise the pressure line by open-
ing the water withdrawal points.
4. Also open any non-return valves fitted in
the suction line.
– When the pump is switched off, resid-
ual water in the hose may flow back
and out of the pump intake.
If the pump is to be completely removed:
D
5. Remove the connected hoses on the
pressure and suction side.
6. Undo the water drain screw and tip the
pump to allow the residual water to drain
out.
7. Screw in the water drain screw again.
– Check that the seal is in place and
correctly functioning.
REMEDY OF FAULTS
The following warning information applies to all work. Exceptions are marked with
.
W A R N I N G
Dangerous electrical voltage!
Death or severe injury from electrocution.
Prior to starting work:
•
Switch off the unit, disconnect the power plug and secure the unit from being switched
on again.
•
Before stepping into or reaching into the water, switch off all units located in the water.
On completion of the work:
•
Restore all the prerequisites for start-up.
Malfunction
Cause
Remedy
Pump does not start.
The pump is switched off.
Switch on the pump.
Power supply interrupted
Check the electrical plug
connections.
The fault current protection
device has tripped.
Switch off the pump and
disconnect the power plug.
Then contact the OASE
Service.
Pump switches off after a
short running period.
Overload protection has
switched the pump off due
to overheating.
•
Clean the connection on
the suction side and the
suction line.
Summary of Contents for ProMax Garden Classic 3000
Page 1: ...ProMax Garden Classic 3000 4500...
Page 2: ...2 ProMax Garden Classic 3000 4500 A POX0029 B POX0030 C D POX0031 POX0033...
Page 112: ...112 ProMax Garden Classic 3000 4500 6 bar 8 30 mA OASE 12 V AC 30 V DC...
Page 114: ...114 ProMax Garden Classic 3000 4500 C 1 2 3 4 5 6 1 2 3 4 D 5 6 7...
Page 115: ...DE EN FR NL ES PT IT DA NO SV FI HU PL CS SK SL HR RO BG UK RU CN 115 OASE...
Page 116: ...116 ProMax Garden Classic 3000 4500 OASE...
Page 119: ...DE EN FR NL ES PT IT DA NO SV FI HU PL CS SK SL HR RO BG UK RU CN 119 6 8 30 OASE...
Page 120: ...120 ProMax Garden Classic 3000 4500 12 30 6 1 4 5 5 5 OASE B 25 0 1...
Page 122: ...122 ProMax Garden Classic 3000 4500 OASE...
Page 123: ...DE EN FR NL ES PT IT DA NO SV FI HU PL CS SK SL HR RO BG UK RU CN 123 OASE...
Page 126: ...126 ProMax Garden Classic 3000 4500 2 6 8 30...
Page 127: ...DE EN FR NL ES PT IT DA NO SV FI HU PL CS SK SL HR RO BG UK RU CN 127 OASE 12 30 6 1 4 5 5 5...
Page 128: ...128 ProMax Garden Classic 3000 4500 OASE B 25 0 1 C 1 2 3 4 5 6 1 2 3 4 D 5 6 7...
Page 129: ...DE EN FR NL ES PT IT DA NO SV FI HU PL CS SK SL HR RO BG UK RU CN 129 OASE...
Page 130: ...130 ProMax Garden Classic 3000 4500 OASE...
Page 134: ...134 ProMax Garden Classic 3000 4500 OASE B 1 25 0 C 1 2 3 4 5 6 1 2 3 4 D 5 6 7...
Page 135: ...DE EN FR NL ES PT IT DA NO SV FI HU PL CS SK SL HR RO BG UK RU CN 135 OASE OASE...
Page 137: ...137 POX0034...
Page 138: ...43922 08 16...