Malfunction
Cause
Remedy
Filter cartridge of the pump be-
comes clogged too soon.
Install an external, larger
pre-filter (optional acces-
sory).
Pump switches off
after a short running
period.
Overload protection has switched
the pump off due to overheating.
•
Clean the connection on
the suction side and the
suction line.
•
Allow the pump to cool
down.
Dry run protection has switched
off the pump.
Clean the intake and suc-
tion line.
Blockage on the suction side
Clean the intake and suc-
tion line.
Non-return valve defective.
•
Contact the OASE ser-
vice.
MAINTENANCE AND CLEANING
W A R N I N G
Dangerous electrical voltage!
Death or severe injury from electrocu-
tion.
Prior to starting work:
•
Switch off the unit, disconnect the power
plug and secure the unit from being
switched on again.
•
Before stepping into or reaching into the
water, switch off all units located in the
water.
On completion of the work:
•
Restore all the prerequisites for start-
up.
W A R N I N G
Risk of injury due to hot water!
Burns to parts of the body.
•
Water remaining in the pump may be
heated to a high temperature in the
event of defective electronics or lack of
water supply on the suction side.
•
Isolate the unit (disconnect from the
power supply) before carrying out any
work on it.
•
Disconnect the pump from the mains at
the main circuit breaker or pull the
power plug, and allow the water to cool
down.
N O T E
Recommendation on regular cleaning:
•
Clean the unit as required but at least
twice per year.
•
Do not use aggressive cleaning agents
or chemical solutions as they could at-
tack the housing or impair the function
of the unit.
•
After cleaning, thoroughly rinse all parts
in clean water.
Cleanfilter
How to proceed:
E
1. Switch off the pump.
2. Disconnect the power plug.
3. Close all shut-off devices on the suction
side if applicable.
4. Unscrew the cover of the filter chamber
and remove.
5. Pull out the filter cartridge.