- GB -
14
ProfiLux LED 1100/01
4.
0.
How to proceed:
E, F
1. Loosen the Allen screws on both sides of the spotlight and tilt the spotlight to allow access to the slot of the installa-
tion bracket.
2. Fasten the installation bracket to the ground/base.
3. Align the spotlight and tighten the Allen screws on both sides.
ProfiLux LED Spot 2200/01, ProfiLux LED Flood 2200/01
4.
0.
How to proceed:
G, H
1. Loosen the Allen screws on both sides of the spotlight and tilt the spotlight to allow access to the slot of the installa-
tion bracket.
2. Fasten the installation bracket to the ground/base.
3. Align the spotlight and tighten the Allen screws on both sides.
Connecting the spotlights
4.
0.
How to proceed:
I
1. Remove the protection cap from PowerBox 24 V DC.
−
The two 24 V DC sockets are connected in parallel. The second 24 V DC socket can be used for supplying other
units (signal feed-through).
2. Fit the connector of the connection cable and secure with the two screws (max. 2.0 Nm).
−
Ensure that the rubber seal is clean and fits exactly.
−
Replace the rubber seal if damaged.
Remedy of faults
Malfunction Cause
Remedy
No supply voltage
Check all cables and connections.
Spotlights do not light up
Switching power pack defective
−
Refer to instructions for use of switching
power pack.
−
Replace switching power pack.
Supply voltage incorrectly connected (poles
reversed)
Correctly connect supply voltage.
Spotlight(s) not connected
Check spotlight connection.
LEDs defective
Replace spotlight(s).
Individual spotlights are not lit.
Switching power pack output defective
−
Connect spotlight(s) to other output.
−
Replace switching power pack.
Operating temperature too high, luminous
intensity automatically reduced.
No measure necessary
Insufficient luminous intensity of the spotlight
Spotlight glass soiled
Clean spotlight glass.
Repair
The unit can only be repaired by
OASE
. Please send the unit to your
OASE
dealer.