- EN -
32
6.5.4
E7
: Pump status detection
(deactivated for pumped system)
The pump status detection signals whether the pump is operating properly via the
Er88
system message.
The status detection is deactivated in the default setting.
If the system message
ER77
or
ER88
is displayed, it is necessary to change the status detection manually.
Proceed as follows
Information
1. Press
several times until
E7
appears in
the display.
•
To cancel and exit the menu: Either wait for 10
s or press
or
.
2.
Keep
pressed for 5
s until the value 0 or
1 is indicated in the display.
•
To cancel and exit the menu: Either wait for 5
s or press
or
.
3. Press
to change the value.
Adjustable range: 0 or 1
•
0: The pump status detection is deactivated.
•
1: The pump status detection is activated.
Important
: Ensure that the value is set to 0 (status detection deactivated).
•
Cancel without saving and exit the menu: Press
or
.
6.6
Reading out the number of cleaning cycles
6.6.1 Cleaning cycles in 24 hours
Proceed as follows
Information
Press
and
for 5 s.
The sum of the automatic and time-
dependent cleaning cycles is saved.
The 4-
digit value is displayed in groups of two digits that appear in
succession in the display.
Example:
01-17
: Represents 117 cleaning cycles
The number is repeated five times after an extended pause to make it
easier to read:
01-17---01-17---01-17---01-17---01-17
Note:
If the mains voltage is switched off, the counter is reset to 0.
Note:
Due to the self-
test of the filter system very different values may be
displayed. The self
-
test monitors the automatic cleaning process. The test
is carried out continuously in a 2 ×
24 hour cycle. The test is only active
from a water temperature >53.6
°F.
•
First 24 hour cycle
−
If at least one automatic cleanin
g process is detected, the cycle is
repeated after the cleaning process has finished.
−
If no automatic cleaning process is detected, the second 24 hour cycle
starts once the first has finished.
•
Second 24 hour cycle
−
The time-
dependent cleaning cycle is deactivated. This reduces the
number of cleaning cycles.
−
If at least one automatic cleaning process is detected, the first 24 hour
cycle starts again once the cycle has finished.
−
If no automatic cleaning process is detected, the system message
Er22
is triggered at the end of the cycle. The time-
dependent cleaning cycle
starts again. If an automatic cleaning process is then detected, the first
24 hour cycle starts again. The system message
Er22
is automatically
reset.
Summary of Contents for Profi Clear Premium Compact L US
Page 1: ...Pro Clear Premium Compact L US...
Page 2: ...2 A ProfiClear0239...
Page 3: ...3 B ProfiClear0243...
Page 4: ...4 C ProfiClear0279 D ProfiClear0164...
Page 5: ...5 E ProfiClear0129 F ProfiClear0130...
Page 6: ...6 G ProfiClear0244 H ProfiClear0245 I ProfiClear0169...
Page 7: ...7 J ProfiClear0240 K ProfiClear0280...
Page 8: ...8 L EGC0009 M EGC0003 N ProfiClear0134...
Page 9: ...9 O P PrifiClear0135 Q ProfiClear0041...
Page 10: ...10 R ProfiClear0137 S ProfiClear0138...
Page 11: ...11 T U ProfiClear0140 ProfiClear0141 V ProfiClear0139...
Page 110: ...110 Proficlear0251 Proficlear0252...
Page 112: ...112 Proficlear0254 Proficlear0255 Proficlear0256...
Page 114: ...114 Proficlear0259...
Page 116: ...76481 01 20...