background image

 

10 

- GB - 

 

Commissioning/start-up 

 

 

Attention! Dangerous electrical voltage. 
Possible consequences:

 Death or severe injury. 

Protective measures:

 

  Prior to reaching into the water, disconnect the power supply to all units used in the water. 

  Disconnect the power plug prior to carrying out work on the unit. 

Switching on:

 Connect power plug to the socket. The unit switches on immediately when the power connection is 

established. 

Switching off:

 Disconnect the power plug. 

Cleaning (B) 

Disconnect the power plug (7) prior to starting cleaning work! 
Remove fountain unit from the water. Hose down the floating body, the nozzle holder and the filter housing and clean 
using a soft brush. 
Cleaning the fountain: Undo the three fastening screws (6). Use a screw driver to lever the fountain out of its centring, 
then remove the fountain (5). Remove soiling from the fountain holder. Reassemble the fountain in the reverse order. 
Cleaning the pump: Detach the pump from the nozzle holder. Clean as instructed in the pump instructions for use. 

Malfunction 

Malfunction Cause 

Remedy 

Pump does not start 

No mains voltage 
 

Check mains voltage 
Clean, check supply lines 

Excessively soiled water 

Clean pump 

Pump switches off after a short running time 

Water temperature too high 

Note maximum water temperature of +35°C 

 

Storage/Over-wintering 

Remove the fountain unit from the water if frost is to be expected. The unit freezing up could entail damage to the 
floating body and the pump. Store the fountain unit in a frost protected place. Adhere to the instructions of use for the 
pump. 

Reviews: