Oase MIDI Floating Fountain LM Operating Instructions Manual Download Page 16

-  EN  - 

16 

 

 

Remedy of faults 

 

 

 

 

 

Attention!

 Dangerous electrical voltage. 

Possible consequences:

 Death or severe injury. 

Protective measures:

 Isolate the unit prior to reaching into the water and carrying out any work on the unit. 

Secure the unit from being switched on inadvertantly. 

 

 

 

 

 

Malfunction Cause

Remedy

Pump does not start 

No mains voltage 

Check the mains voltage and the supply lines 

Filter basket soiled 

Clean the filter basket under running water 
using a brush 

Motor defective 

Contact OASE 

Pump switches off after a short running period 

Pump overloaded due to heavily soiled water 

  Improve the water quality to enhance the 

pump's operating life 

  Clean the filter basket under running water 

using a brush 

Water temperature too high 

Only operate the unit at the water temperature 
specified in the technical data 

Pump overloaded because the filter basket is 
soiled 

Clean the filter basket under running water 
using a brush 

Motor defective 

Contact OASE 

Motor (overload) protection switch (CEE) incor-
rectly set 

Have the switch checked and adjusted by a 
qualified electrician 

Irregular water image effect, loud flow noise 

Filter basket soiled 

Clean the filter basket under running water 
using a brush 

Irregular 'water' picture, picture fluctuates nota-
bly 

The float body moves 

Check the float body fastening 

The 'water' picture is affected by strong wind 

Fit a wind gauge with switch-off function 

 

Switch on the unit 
MIDI Floating Fountain LM, 230 V

: Allow the unit to cool down (approx. 30 seconds), then press the button (38) at the 

control box (35). Pump will start. 

MIDI Floating Fountain LM, 400 V

: Press the green button (41) at the motor (overload) protection switch (36). Pump 

will start. 

 

 

 

Cleaning 

 

 

 

 

 

Attention!

 Dangerous electrical voltage. 

Possible consequences:

 Death or severe injury. 

Protective measures:

 Isolate the unit prior to reaching into the water and carrying out any work on the unit. 

Secure the unit from being switched on inadvertantly. 

 

 

 

 

If necessary, clean the unit with clear water using a soft brush. 

 

 

 

Storage/Over-wintering 

 

Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage. 

 

 

 

Disposal 

 

 

Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided. 
Disable the unit beforehand by cutting off the cables. 

 

 

Summary of Contents for MIDI Floating Fountain LM

Page 1: ...Gebrauchsanleitung DE Operating instructions EN Notice d emploi FR Gebruiksaanwijzing NL Instrucciones de uso ES MIDI Floating Fountain LM 230 V 1 1 kW 400 V 2 2 kW 400 V 4 kW...

Page 2: ...2...

Page 3: ...3...

Page 4: ...4...

Page 5: ...5...

Page 6: ...6...

Page 7: ...ang Bild A Anzahl Beschreibung 1 1 Pumpenaggregat 5 1 Schwimmer 1 Beipack mit Befestigungsmaterial 1 Gebrauchsanleitung Bild B 4 1 nur 1 1 kW Ger t Reduzierst ck bereits montiert Hinweis D se 2 und lf...

Page 8: ...len und durchzuf hren Das Arbeiten als Fach kraft umfasst auch das Erkennen m glicher Gefahren und das Beachten einschl giger regionaler und nationaler Normen Vorschriften und Bestimmungen Bei Fragen...

Page 9: ...lanschen 6 festschrauben Beleuchtungs Set Lunaqua 10 montieren optional E L Am Ger t k nnen Sie drei Beleuchtungs Sets Lunaqua 10 befestigen Die Beleuchtungs Sets sind als Zubeh r erh lt lich Fragen S...

Page 10: ...ngen Steine auf den Teichboden versenken und das Ger t zu Wasser lassen Achtung Das Anschlusskabel 31 zugentlasten und den Netzstecker vor N sse sch tzen Control Box 35 Motorschutzschalter 36 aufstell...

Page 11: ...e Elek trofachkraft Wasserbild unregelm ig laute Str mungsge r usche Filterkorb verschmutzt Filterkorb mit einer B rste und unter flie en dem Wasser reinigen Wasserbild unregelm ig schwankt stark Schw...

Page 12: ...ctions when passing the unit on to a new owner Scope of delivery Fig A Number Description 1 1 Pump unit 5 1 Float body 1 Accessory kit containing fastening material 1 Operating instructions Figure B 4...

Page 13: ...recognition of possible hazards and the adherence to the pertinent regional and national standards rules and regu lations For your own safety please consult a qualified electrician The unit may only...

Page 14: ...to the fastening flanges 6 Fitting the spotlight set Lunaqua 10 optional E L Three Lunaqua 10 spotlight sets can be fitted to the unit The spotlight sets are available as accessories Ask your OASE sp...

Page 15: ...ll relieve the connection cable 31 and protect the power plug from moisture Installation of the Control Box 35 Motor overload protection switch 36 M P Install the control box motor overload protection...

Page 16: ...qualified electrician Irregular water image effect loud flow noise Filter basket soiled Clean the filter basket under running water using a brush Irregular water picture picture fluctuates nota bly T...

Page 17: ...ces faisant partie de la livraison Bild A Quantit Description 1 1 Groupe motopompe 5 1 Flotteur 1 Paquet contenant le mat riel de fixation 1 Notice d emploi Figure B 4 1 Appareil 1 1 kW uniquement ra...

Page 18: ...dentifier d ventuels dangers et respecter les normes r gionales et nationales les r glements et les dispositions en vigueur qui se rapportent aux t ches ex cuter En cas de questions et de probl mes pr...

Page 19: ...clairage Lunaqua 10 en option E L Vous pouvez fixer trois kits d clairage Lunaqua 10 sur l appareil Les kits d clairage sont disponibles dans la gamme des accessoires Adressez vous votre distributeur...

Page 20: ...ordement 31 et prot ger la fiche de contact contre l humidit Mise en place du bo tier de commande 35 disjoncteur protecteur pour moteur 36 M P Mettre le bo tier de commande disjoncteur protecteur pour...

Page 21: ...s d un lectricien sp cialis Jeux d eau irr guliers bruits de d bit forts Panier de filtration colmat Nettoyer le panier de filtration l eau courante et au moyen d une brosse Jeux d eau irr guliers for...

Page 22: ...r wanneer het ap paraat van eigenaar verwisselt Leveringsomvang Afb A Aantal Beschrijving 1 1 Pompaggregaat 5 1 Drijver 1 Pakket met bevestigingsmaterialen 1 Gebruiksaanwijzing Af beelding B 4 1 slech...

Page 23: ...het herkennen van mogelijke gevaren en het in acht nemen van geldige regionale en nationale normen voorschriften en bepalingen Neem voor uw eigen veiligheid in geval van vragen of problemen contact op...

Page 24: ...de borgringen 8 en de moeren 9 aan de bevestigingsflenzen 6 Montage van de verlichtingsset Lunaqua 10 optioneel E L Op het apparaat kunt u drie verlichtingssets Lunaqua 10 bevestigen De verlichtingss...

Page 25: ...enen naar de bodem van de vijver zinken en leg het apparaat in het water Let op Zorg voor trekontlasting van de aansluitkabel 31 en bescherm de netstekker tegen vocht Control Box 35 motorbeveiliging 3...

Page 26: ...gelmatig veel lawaai van stromend water Filter verontreinigd Reinig de filterkorf met een borstel onder stromend water Waterbeeld onregelmatig schommelt sterk Vlotter verplaatst zich Bevestiging van d...

Page 27: ...uministro Ilustraci n A Cantidad Descripci n 1 1 Grupo de bombas 5 1 Flotador 1 Paquete de accesorios con material de fijaci n 1 Instrucciones de uso Ilustraci n B 4 1 S lo equipo 1 1 kW Reductor ya m...

Page 28: ...rsonal t cnico tambi n incluyen el reconocimiento de los posibles peligros y el cumplimiento de las correspondientes normas prescripcio nes y disposiciones regionales y nacionales En caso de preguntas...

Page 29: ...iluminaci n Lunaqua 10 opcional E L Vd puede fijar en el equipo tres juegos de iluminaci n Lunaqua 10 Los juegos de iluminaci n se pueden comprar como accesorios Consulte su comerciante especializado...

Page 30: ...cable de conexi n 31 y proteja la clavija de red contra la humedad Emplazamiento de la caja de control 35 del interruptor de protecci n 36 M P Emplace la caja de control el interruptor de protecci n a...

Page 31: ...o Encargue la comprobaci n y el ajuste a perso nal especializado en el ctrica La imagen de agua es irregular se oyen ruidos de flujo extra os Cesto de filtro sucio Limpie el cesto de filtro bajo agua...

Page 32: ...DI Foating Fountain LM Peso caja de control guardamotor Profundidad m nima del agua Capacidad de elevaci n Temperatura del agua Longitud del cable MIDI Floating Fountain LM 1 1 kW 230 V 700 x 1150 mm...

Page 33: ...ating instructions FR Imperm able aux poussi res Etanche l eau jusqu une profondeur de 4 m Ne pas recycler dans les ordures m nag res Attention Lire la notice d emploi NL Stofdicht Waterdicht tot een...

Page 34: ...34 MDI0001...

Page 35: ...35...

Page 36: ...13556 07 15...

Reviews: