OASE UNDERWATER LIGHTS must be connected by a certified electrician to a properly grounded and GFCI (Ground 
Fault Circuit lnterrupter) protected 120 Volt AC circuit in accordance with local electrical code requirements. Cord to be 
connected to the supply source in a certified and appropriate junction box located above maximum water level.
Do not use OASE UNDERWATER LIGHTS in swimming pools, spas, hot tubs, etc. OASE UNDERWATER LIGHTS must 
be submersed before lighting.
Do not operate light in dry conditions. Read product label carefully and thoroughly.
PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY AND THOROUGHLY. FAILURE TO COMPLY WITH 
THESE IMPORTANT REQUIREMENTS COULD CAUSE SERIOUS OR FATAL INJURY OR DAMAGE. 

ELECTRICAL REQUIREMENTS

OASE UNDERWATER LIGHTS must be connected by a certified electrician to a properly grounded and GFCI (Ground 
Fault Circuit Interrupter) protected 120 Volt AC circuit in accordance with local electrical code requirements.

DISCONNECT ELECTRICAL 

circuit before

 

- Moving light, cleaning light, replacing lamp.
- Use replacement lamps of same electrical ratings, shape and size only.
- Avold water penetration into light housing when replacing lamp.
- Disconnect electrical circuit before entering water area.
- Do not remove cord.
- Do not pinch or twist cord.
- Do not remove any labels.
- Do not expose light to other than water.
- Do not operate light at low water level.

SAFETY INSTRUCTIONS 

- Disconnect electrical circuit before moving or cleaning light.
- Disconnect electrical circuit before opening light enclosure for lamp replacement.
- Avoid water penetration into light housing when replacing lamp.
- Do not carry or pull light by power cord.
- Mechanical damage to light could cause serious or fatal injury or damage.
- Disconnect electrical circuit before entering water area. 

SETUP and STARTUP (A-B)

The unit comes fully assembled. (B) Undo screw M6 and nut M6 and remove the foot from the retaining rings, fit the foot 
on firm ground using a 6 mm screw connection so as to ensure that the unit presents no danger for anybody and cannot 
be disassembled without tools (permanent local installation). Fasten the unit to the foot using an M6 screw and an M6 
nut and ensure firm seating. Connect the power supply and check the spotlight function.

Fitting a coloured glass or safety glass (optional)

Insert the coloured glass (a = blue, b = yellow, c = green, d = red,) or the safety glass (e) in the corresponding recess in 
the upper section of the housing and fix using four retaining elements and 5x10 screws.

Exchanging the bulb

Adhere to the safety information given above! Disconnect the power supply and take measures to prevent unintentional 
switching on. Use the appropriate original bulb PAR 38 120 V/ 80 W from OASE. Undo the four M5x35 screws and 
remove the upper section of the housing. Ensure that no moisture can enter the unit. Replace bulb and O rings, refit the 
upper section of the housing. Reconnect to the power supply and check function.

Important! Only original bulbs from OASE may be used.

Wearing parts

Bulbs and sealing rings are wear parts and are excluded from the warranty.

Cleaning

Adhere to the safety information given above! Carry out the steps as specified under 'Replacing the bulbs'. Only use water 
and a soft brush. Ensure that no moisture can enter the unit.

Repair

In the event of damage of the housing, the unit cannot be repaired and, therefore, has to be disposed of.

Disposal

Dispose of the unit in accordance with the national legal regulations. 

Malfunctions

Trouble shooting

Cause

Remedy

Lamp does not light up

Power supply interrupted

Check power supply 
Check bulb, replace, if necessary
Clean contacts

Light intensity decreases

Lamp glass soiled

Cleaning

Water in the spotlight

Seal defective

Check and replace seal

English

Beschreibung.pdf   1

19.09.2013   15:40:17

Summary of Contents for Lunaqua 5.1

Page 1: ...d Operating Instructions Garantie mode d emploi et consignes de s curit Garantia Instructivo de Seguridad y de Operaciones 29751 09 13 Lunaqua 5 1 USA pdf 1 19 09 2013 12 09 38 29751 09 13 Lunaqua 5 1...

Page 2: ...B A A 29751 09 13 Lunaqua 5 1 USA pdf 2 19 09 2013 12 09 38 29751 09 13 Lunaqua 5 1 USA pdf 2 19 09 2013 12 10 08...

Page 3: ...a SETUP and STARTUP A B The unit comes fully assembled B Undo screw M6 and nut M6 and remove the foot from the retaining rings fit the foot on firm ground using a 6 mm screw connection so as to ensure...

Page 4: ...under the terms of this limited warranty you should return the product to your OASE dealer along with your original receipt of purchase and any other limited warranty documentation you have for repla...

Page 5: ...er ce que de l humidit ne p n tre pas dans l appareil R paration L appareil n est pas r parable en cas d endommagement du carter et doit tre pour cette raison remplac Recyclage Recycler l appareil con...

Page 6: ...TAL O EN DA O REQUISITOS ELECTRICOS Las LUCES SUBACUATICAS OASE deben ser conectadas por un electricista certificado a un circuito protegido por 120 voltios AC con apropiada descarga a tierra y con un...

Page 7: ...mpoco cubre aquellas partes del producto que est n sujetas al desgaste y deterioro normal durante el uso del produc to como Propulsores de las bombas Almohadillas y medios de los filtros L mparas en e...

Page 8: ...hnical data Dimensions Cable outlets Socket Bulbs Rated voltage Radiation angle Dimensions Sorties des c bles Douille Ampoule Tension nominale Angle de projection Dimensiones Salidas de cable Pie de l...

Page 9: ...29499 GAW Lunaqua_51 44 pdf 1 02 10 2013 10 09 23...

Page 10: ...29751 09 13 Lunaqua 5 1 USA pdf 10 19 09 2013 12 09 40 29751 09 13 Lunaqua 5 1 USA pdf 10 19 09 2013 12 10 11...

Page 11: ...29751 09 13 Lunaqua 5 1 USA pdf 11 19 09 2013 12 09 40 29751 09 13 Lunaqua 5 1 USA pdf 11 19 09 2013 12 10 11...

Page 12: ...OASE North America Inc www oase livingwater com 29751 09 13 29751 09 13 Lunaqua 5 1 USA pdf 12 19 09 2013 12 09 40 29751 09 13 Lunaqua 5 1 USA pdf 12 19 09 2013 12 10 11...

Reviews: