- EN -
18
3.3
Connecting a UVC clarifier
Prerequisite:
•
The container is open. (→
Opening the container)
•
The screen hol
der is hinged up. (→
Hinging the screen holder up/down)
How to proceed:
K
1. Fit the UVC clarifier with flat seal into the inlet opening.
2. Screw the distributor nut with O ring onto the stepped hose adapter and hand tighten.
– Read the UVC clarifier operating instructions.
3.4
Connecting the outlet
•
Use suitable pipes.
•
Do not use any right-angled bends. Bends with a maximum angle of 45° are very efficient.
•
Standing water in pipes can freeze when there is a hard frost and cause pipes to burst. For this reason, lay
the pipes and hoses with a gradient (50 mm/m) to ensure that they can run empty.
•
Pipe dimensions: (→
Technical data)
Fitting the DN 110 outlet
BioTec ScreenMatic² 38000: The outlet is not fitted on delivery.
Prerequisite:
•
The container is open. (→
Opening the container)
How to proceed:
L
1. Fit the O ring onto the outlet.
2. Fit the outlet into the respective hole of the container wall from the outside.
– Ensure that the raised marking is at the top and aligned in relation to the hole pattern.
3. Fasten the outlet from the inside with oval head screws.
– Tighten all screws diagonally using the cordless screwdriver to ensure that the sealing ring is uniformly
applied. Further tighten the screws using a Phillips screwdriver.
N O T E
Build supports to increase the stability of the pipe construction and to prevent the pipe construction
from sagging at the discharge.
3.5
Connecting the dirt outlet
The water in the container can be drained via the dirt outlet with slide valve at the bottom of the container
when required (for cleaning, repair, overwintering).
•
Connect the pipe and drain the dirty water, for example, into a flower bed or into the sewage system.
•
Pipe dimension
s: (→
Technical data)
3.6
Carry out the electrical connection
How to proceed:
M
1. Thread the connection cable through the opening in the container wall and seal off the opening using the
sealing plug.
– Ensure that the connection cable inside the container is sufficiently long so that it is not subjected to ten-
sion when the ScreenMatic rotating screen unit is hinged up.
– Avoid tangling of the cable inside the container.
2. Connect the plug of the connection cable to the socket on the transformer and hand-tighten the union nut.
Summary of Contents for BioTec ScreenMatic 2
Page 2: ...2 A BTC0087 B BTC0066 C BTC0094...
Page 3: ...3 D BTC0067 E BTC0095...
Page 4: ...4 F BTC0052...
Page 5: ...5 G BTC0070 H AMX0071 I AMX0070...
Page 6: ...6 J BTC0096...
Page 7: ...7 K BTC0104 L BTC0072...
Page 8: ...8 M BTC0097 N BTC0062...
Page 9: ...9 O BTC0073 P BTC0099...
Page 10: ...10 Q BTC0098 R BTC0100...
Page 11: ...11 S BTC0101 T BTC0102...
Page 12: ...12 U BTC0103 V BTC0054...
Page 60: ...60 Pos BioTec ScreenMatic 18000 33 34670 34 48781 35 34733 36 25524 37 48780 BTC0042...
Page 63: ...63 Pos BioTec ScreenMatic 24000 33 34670 34 48781 35 45254 36 45325 37 48780 BTC0083...
Page 68: ...OASE North America Inc 330 274 8317 www atlantic oase com 43854 10 22...