36

 

 

 

3.1 

Hazards encountered by the combination of water and electricity 

 

The combination of water and electricity can lead to death or severe injury from electrocution, if the 
unit is incorrectly connected or misused. 

 

Prior to reaching into the water, always switch off the mains voltage to all units used in the water. 

 

 

 

3.2 

Danger for persons with pacemakers 

 

 

The container cover contains a magnet with a strong magnetic field that may affect the operation of 
pacemakers or implantable cardioverter defibrillators (ICDs). Always keep magnets at least 20 cm 
away from implanted devices. 

 

 

 

3.3 

Correct electrical installation 

 

 

Electrical installations must meet the national regulations and may only be carried out by a qualified 
electrician. 

 

A person is regarded as a qualified electrician, if, due to his/her vocational education, knowledge and 
experience, he or she is capable of and authorised to judge and carry out the work commissioned to 
him/her. This also includes the recognition of possible hazards and the adherence to the pertinent 
regional and national standards, rules and regulations. 

 

For your own safety, please consult a qualified electrician. 

 

The unit may only be connected when the electrical data of the unit and the power supply coincide. 
The unit data is to be found on the unit type plate or on the packaging, or in this manual. 

 

 

Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current 
protection device. 

 

 

Extension cables and power distributors (e. g. outlet strips) must be suitable for outdoor use. 

 

 

Protect the plug connections from moisture. 

 

 

Only plug the unit into a correctly fitted socket. 

 

 

 

3.4 Safe 

operation 

 

 

 

Never operate the unit if either the electrical cables or the housing are defective! 

 

Do not carry or pull the unit by its electrical cable.  

 

Route cords/hoses/lines in a way that they are protected against damage, and ensure that they do not 
present a tripping obstacle. 

 

Only open the unit housing or its attendant components, when this is explicitly required in the operating 
instructions. 

 

Only execute work on the unit that is described in this manual. If problems cannot be overcome, please 
contact an authorised customer service point or, when in doubt, the manufacturer. 

 

Only use original spare parts and accessories for the unit. 

 

Never carry out technical modifications to the unit. 

 

 

The power connection cables cannot be replaced. When the cable is damaged, the unit or the 
component needs to be disposed of. 

 

 

Keep the socket and power plug dry. 

 

 

Overvoltage in the mains could lead to operating malfunctions of the unit. For information, please refer 
to chapter "Remedy of faults". 

 

 

Do not breath in the spray from the rinsing device. The spray may contain harmful bacteria. When the 
container cover is lifted up, the rinsing device continues operating. 

 

Summary of Contents for BioTec Premium 80000

Page 1: ...40115 12 14 BioTec Premium 80000 40115_OASE GAW_BioTec_Premiuml_80000_A4_01_end_ 16 12 14 08 21 Seite 2 ...

Page 2: ... 2 A BTC0016 B BTC0017 ...

Page 3: ... 3 C BTC0030 D BTC0032 ...

Page 4: ... 4 E BTC0027 F G BTC0022 BTC0019 ...

Page 5: ... 5 H I ProfiClear0040 BTC0018 J K BTC0031 BTC0026 L BTC0020 ...

Page 6: ... 6 M BTC0021 N BTC0025 ...

Page 7: ... 7 O BTC0028 P BTC0029 Q R BTC0023 BTC0024 ...

Page 8: ...stem 39 5 Commissioning start up 40 5 1 Adjusting the level detection device 40 5 2 Biological filter starter 40 5 3 Order of starting up steps 41 6 Operation 42 6 1 Control system overview 42 6 1 Switching ON OFF 42 6 2 Operating modes 43 6 1 Manual cleaning 43 6 1 Settings in the menus 43 6 1 1 CL Cleaning time Cleaning 43 6 1 2 EC Extended cleaning time Extra Cleaning 44 6 1 3 In Time dependent...

Page 9: ... Adhere to the safety information for the correct and safe use of the unit Keep these instructions in a safe place Please also hand over the instructions when passing the unit on to a new owner 1 1 Symbols used in these instructions GB The symbols used in this operating manual have the following meanings Risk of injury to persons due to dangerous electrical voltage This symbol indicates an imminen...

Page 10: ... bends 2 union nuts 2 flat seals 60 47 3 mm 13 Connection set for connecting filter pumps 1 38 mm 1 hose connector 1 50 mm 2 hose connector 1 union nut for hose connector 1 40 60 mm hose clip 1 90 2 connection bend 1 union nut for connection bend 1 flat seal 56 43 3 mm 14 2 38 mm 1 connection closed with sealing plugs optional connection for a Bitron UVC clarifier 15 50 mm 2 connection for connect...

Page 11: ...ired High flow rate of 12500 l h Simple extension using modules from the ProfiClear Classic series Easy upstream connection of UVC clarifiers Perfectly tailored to the AquaMax Eco Premium filter pump from OASE 2 3 Intended use BioTec Premium 80000 referred to in the following as unit may only be used as specified in the following For cleaning garden ponds Operation under observance of the technica...

Page 12: ...te or on the packaging or in this manual Ensure that the unit is fused for a rated fault current of max 30 mA by means of a fault current protection device Extension cables and power distributors e g outlet strips must be suitable for outdoor use Protect the plug connections from moisture Only plug the unit into a correctly fitted socket 3 4 Safe operation Never operate the unit if either the elec...

Page 13: ...effectively absorbs the noises Select the location of the filter system in order to avoid noise disturbance Plan the installation of the filter system With careful planning taking the ambient conditions into account you will obtain optimum operating results The following conditions must be met The filter system starts the cleaning cycles automatically day and night These cleaning cycles cause nois...

Page 14: ...nside of the container Hand tighten the union nut Ensure that the connection bend points downwards A correctly positioned connection bend prevents unintended overflow emptying of the pond and also serves to reduce noise emissions Note If two pumps are connected but only one pump is switched on water can flow back via the hose of the switched off pump without being filtered Protective measures Alwa...

Page 15: ... drains away via the DN 110 coarse dirt outlet top outlet on the container on the input side Connect a suitable DN 110 pipe and drain the dirty water into the sewer system 4 3 Connecting and installing the control system The cable harness of the Drum Filter Module contains the connection cables of the signal box the drum motor and the rinsing pump Connecting H Connect the three connectors of the c...

Page 16: ...control system until the container is flooded with water 5 1 Adjusting the level detection device A rise in the water level during operation indicates that the system is soiled The level detection device signals possible soiling to the control system and the cleaning cycle is started The water level in the filter system is independent of the water level in the pond The water level in the filter sy...

Page 17: ...p 6 Fit the container cover The filter drum is stopped for safety reasons if the filter cover is lifted 7 Switch on the control system and perform any necessary adjustments Operation 8 Switch on the filter pump and UVC clarifier if applicable Ensure that the water is returned to the pond via the return pipe 9 Check all pipes hoses and their connections for leaks Expansion seals may leak initially ...

Page 18: ...nded cleaning time Extra Cleaning EC time dependent cleaning Interval In 5 Clean button for starting the manual cleaning cycle and for cancelling the active cleaning cycle LED 6 is lit when the cleaning cycle is active 6 Blue LED LED is lit Cleaning cycle active 6 2 Switching ON OFF How to proceed Information Switching on Press for 3 s LED 3 is lit green The display indicates On for approx 5 s The...

Page 19: ...pressing the button 6 5 Settings in the menus Note Settings can only be made in the menus when the control system is switched on Switching on off 6 5 1 CL Cleaning time Cleaning Setting the cleaning time changes the duration of the cleaning cycle Extend the cleaning time if the dirt is not completely carried away by the water for example if the drain pipes are very long or have lots of bends or th...

Page 20: ...cause even if there is only a small amount of dirt excrement is always removed from the water cycle before it leads to build up of nutrients Adjust the time interval to meet the requirements The Drum Filter Module is normally optimally set with a time interval of 20 minutes default setting The function is deactivated with a time setting of 0 minutes The time dependent cleaning cycle does not have ...

Page 21: ...5 s The sum of the automatic manual and time dependent cleaning cycles is saved The 8 digit value is divided into four groups of two digits that appear in the display in succession Example 00 00 12 44 Corresponds to 1244 cleaning cycles The number is repeated four times after an extended pause to make it easier to read 00 00 12 44 00 00 12 44 00 00 12 44 00 00 12 44 Note If the mains voltage is sw...

Page 22: ...ode is active and time dependent cleaning is deactivated Time dependent cleaning is automatically activated by floats after check mode Er33 20 cleaning cycles in succession Manual cleaning Time dependent cleaning Level detection device stuck or defective Clean the level detection device to ensure that the mechanics operate freely replace if necessary Press key for 5 s Screen elements heavily soile...

Page 23: ... up phase of the filter system e g during the first start up Fish are spawning Wait until the soiling decreases This operating status is atypical Avoid long term operation in this state Press key for 5 s Automatic if the number of cleaning procedures drops below 960 Pond heavily soiled Clean the pond Reduce the amount of soiling Install the filter pump in an elevated position Screen elements heavi...

Page 24: ...locked Large particles of dirt such as string algae are blocking the dirt channel Remove a screen element and clean the dirt channel Filter drum is partially soiled cannot be cleaned Rinsing nozzle clogged Clean the rinsing nozzle replace if necessary Water is flowing via the emergency overflow Screen elements clogged Clean descale the screen elements Pump capacity too high Reduce the pump capacit...

Page 25: ...initial start up Thoroughly clean the pond The bacteria of the biological filter system are not sufficiently established Use OASE Biokick filter starter The level detection device is clogged or soiled Clean the level detection device The level detection device is set to position 2 Set the level detection device to position 1 Adjusting the level detection device A cloud of dirt briefly appears in t...

Page 26: ...ystem for any error messages Error messages Check the area in front of the separating plate and the inside of the filter drum for excessive soiling e g string algae To do this remove a screen element Removing fitting a screen element Check the water level at the water level indicator on the inner cover Removing accumulated dirt Dirt that cannot be collected by the filter drum sinks to the bottom a...

Page 27: ...one side and lift up slightly then unlock the other side If the inner cover is too heavy release the foam holders allowing them to lower into the container before lifting out the inner cover 3 Pull the foam holders up slightly press both engagement hooks on the foam holders together and push them down and out of the inner cover 4 Press in the four engagement hooks on the top foam part and take out...

Page 28: ... Turn the screen element and push the two hinges onto the support of the filter drum 6 Use the cross element to pull the screen element up 7 Close the locking mechanism turn through 180 8 6 2 Decalcifying the screen elements The error messages Er33 Er55 or an excessive rise in the frequency of cleaning cycles counter indicate that there are limescale deposits on the screen elements Reading out the...

Page 29: ...uld damage the screen elements Fitting How to proceed P Before fitting the filter drum check that the drum seal is undamaged and correctly positioned Lubricate the seal with the supplied grease Replace the drum seal if damaged 1 Fitting a new drum seal Ensure that the recess in the drum seal is at the top 2 Ensure that the separating plate is completely seated in the groove of the drum seal Contin...

Page 30: ... the circulation by the filter system Position the pump nearer to the surface of the water so that only colder water closer to the surface of the pond enters the pump Insulate the return pipes from the filter system into the pond Do not allow water to flow into the pond via a water course The unit is not protected from frost Take the unit out of operation at water temperatures below 8 C or at the ...

Page 31: ...Permissible water temperature C 4 35 Length of drum filter cable harness m 1 Airborne noise emitted Normal operation dB A 50 Operation with rinsing cycle dB A 70 Dimensions L W H mm 885 675 820 Weight Without water kg 70 With water kg 280 Rinsing pump Water pressure bar 4 Water consumption l m 4 Drum Diameter mm 500 Width mm 160 Screen elements Quantity pce 6 Inlet filter pump Quantity pce 1 Conne...

Page 32: ...ing 8 A 250 træg Mulig fare for personer med pacemaker Beskyt mod direkte sollys Afinstaller enheden ved frostvejr Grib ikke fat i indløbet eller afløbet Risiko for kvæstelser ved skydebevægelse OBS Læs brugsanvisningen Må ikke bortskaffes med det almindelige husholdningsaffald SV Dammskyddad Skyddad mot droppvatten Smältsäkring 8A 250V trög Möjlig risk för personer med pacemaker Skydda mot direkt...

Page 33: ...273 BTC0001 ...

Page 34: ...274 BTC0003 BTC0002 BTC0004 ...

Page 35: ...275 BTC0006 BTC0005 BTC0007 ...

Page 36: ...276 BTC0009 BTC0010 BTC0011 BTC0008 BTC0012 ...

Page 37: ...277 BTC0014 BTC0013 BTC0015 ...

Page 38: ...40115 01 15 ...

Reviews: