![background image](http://html1.mh-extra.com/html/oase/biorb-halo-15-mcr-led/biorb-halo-15-mcr-led_operating-instructions-manual_720326024.webp)
- EN -
24
biOrb HALO
REMEDY OF FAULTS
Malfunction
Cause
Remedy
The water becomes soiled within a
short time.
The filter cartridge is exhausted.
Replace the filter cartridge.
Overfeeding
Reduce the amount of food.
Too many fish
Reduce the number of fish.
Aerator pump doesn't start up.
No mains voltage
•
Check the connection of the aerator pump at
the transformer.
•
Check the mains voltage.
Aerator pump defective
Replace the aerator pump.
Aerator pump is noisy.
Aerator pump is vibrating.
Place the aerator pump onto a softer sur-
face.
Fewer air bubbles in the air tube than
normal
Aerator is exhausted.
Replace the aerator.
The aerator pump is noisy and there
are still fewer air bubbles even after
replacement of the aerator.
The aerator pump is only functioning to a
limited extent.
Replace the aerator pump immediately.
The lighting cannot be switched on. No mains voltage
Check the mains voltage and power connec-
tion cables.
The lighting module is not responding
to the remote control.
Too large a distance between the remote
control and the aquarium.
Reduce the distance.
The remote control battery capacity is ex-
hausted.
Replace the battery.
The remote control is not pointing towards
the aquarium.
Point the remote control at the aquarium.
TECHNICAL DATA
biOrb HALO
30 LED 60 LED
15 MCR
LED
30 MCR
LED
60 MCR
LED
Plug-in transfor-
mer
Primary rated voltage
V AC
230
230
230
230
230
Secondary rated voltage
V AC
12
12
12
12
12
Mains frequency
Hz
50
50
50
50
50
Protection type
IP20
IP20
IP20
IP20
IP20
Aerator pump
Rated voltage
V AC
12
12
12
12
12
Rated power
W
0.8
0.8
0.8
0.8
0.8
Length of the connection cable
m
1.5
1.5
1.5
1.5
1.5
Lighting unit
Energy efficiency class
A++
A++
A
A
A
Energy efficiency
lm/W
85
85
17
17
17
Rated power
W
2
2
2.9
2.9
2.9
Rated voltage
V AC
12
12
12
12
12
Length of the connection cable
m
1.5
1.5
1.5
1.4
1.4
Remote control
MCR
Battery type
–
–
CR 2025
CR 2025
CR 2025
SYMBOLS ON THE UNIT
Protected from contact with fingers.
Protection class II, reliable electrical isolation from the mains by reinforced or double insulation.
For use indoors.
Do not dispose of with household waste.
Read and adhere to the instructions for use.
Summary of Contents for biOrb HALO 15 MCR LED
Page 1: ...HALO...
Page 2: ...DE 2 biOrb HALO A BOB0021...
Page 3: ...DE 3 B BOB0022...
Page 4: ...DE 4 biOrb HALO C BOB0023 D BOB0024 E BOB0032...
Page 5: ...DE 5 F BOB0025...
Page 6: ...DE 6 biOrb HALO G BOB0015 H I BOB0035 BOB0036...
Page 7: ...DE 7 J BOB0027...
Page 8: ...DE 8 biOrb HALO K BOB0028...
Page 9: ...DE 9 L BOB0029 M BOB0030...
Page 10: ...DE 10 biOrb HALO N BOB0031...
Page 137: ...BG 137 BG 8 EN 60335 2 55 A A...
Page 141: ...BG 141 J 1 OASE biOrb 46025 46026 2 K 1 2 3 4 L 1 2 3 M 1 2 3 N 1 2 3...
Page 144: ...UK 144 biOrb HALO UK 8 EN 60335 2 55 A...
Page 148: ...UK 148 biOrb HALO J 1 OASE biOrb HALO 46025 46026 2 K 1 2 3 4 L 1 2 3 M 1 2 3 N 1 2 3...
Page 151: ...UK 151 II...
Page 152: ...RU 152 biOrb HALO RU 8 EN 60335 2 55...
Page 159: ...RU 159 II...
Page 160: ...CN 160 biOrb HALO CN 8 EN 60335 2 55 A A...
Page 164: ...CN 164 biOrb HALO K 1 2 3 4 L 1 2 3 M 1 2 3 N 1 2 3 PB Cd Hg Li...
Page 167: ...167...
Page 168: ...48040 02 17...