MAINTENANCE AND CLEANING 

For cleaning and maintenance, first separate the filter 

unit from the pump unit and then remove both units 

from the water. 

 

Maintenance  of  the  pump  unit  involves  cleaning 

the central outlet, flow-out nozzles and impeller 

unit. 

 

If necessary, clean with clear water using a soft 

brush. 

 

Do not use cleaning agents or chemical solutions. 

We recommend using OASE PumpClean for remov-

ing calcium deposits. 

 

Cleaning and replacement cycles for filter media 

such as foam filters are dependent on the size of 

the aquarium and the number of fish. Therefore, it 

is necessary to clean and replace the filter media 

as required to ensure optimum filter performance. 

 

If  there  are  several  foam  filters:  Clean  or  replace 

the  foam  filters  at  different  times.  This  saves 

enough useful bacteria to ensure good biological 

filtration of the water. 

 

Recommendation for clear water: Replace the filter 

fleece at least each time the filter sponges are 

cleaned. 

 

Cleaning or replacing the filter media 

 F 

 

Carefully pull the filter unit from the pump unit 

(magnetic holder) and 

remove from the aquarium.

 

 

Separate the filter modules (press the button). 

 

Empty  the  filter  modules  over  a  wash  basin  and 

rinse the foam filters or filter fleece under warm 

water or replace. 

 

 

Pump unit maintenance 

 G 

 

Remove the pump unit.

 

– 

Release the suction cups with the aid of the tab. 

 

Pull up the nozzle unit and separate it from the 

base plate. 

 

Clean the central outlet and flow-out nozzles. 

 

Reassemble the unit in the reverse order.

 

 H 

 

Pull the pump lid off downward. 

 

Remove the impeller unit, clean or 

replace. 

 

Reassemble the unit in the reverse order.

 

– 

Ensure that the two rubber bearings are correct-

ly seated. 

 

Re-installing the unit 

 

Fit the pump unit and filter unit together again, 

and install and connect as before in the aquarium 

(→ 

Installation and connection)

– 

Flow-out nozzles just below the surface of the 

water 

– 

Outlet control knob adjusted as required 

– 

Power connection cables with drip loop 

 

WEAR PARTS 

 

Filter fleece 

 

Foam filter 

 

Suction cups 

 

Impeller unit 

 

DISPOSAL 

Do not dispose of this unit with domestic waste! For 

disposal purposes, please use the return system 

provided.  Render  the  unit  unusable  beforehand  by 

cutting the cables. 

 

Summary of Contents for BioPlus 100

Page 1: ...BioPlus 50 100 43092_Gebrauchsanleitung_BioPlusBioPlusThermo indd 1 08 01 16 14 11...

Page 2: ...2 BioPlus 50 100 A BPL0011 B BPL0002...

Page 3: ...3 C BPL0004 D BPL0005...

Page 4: ...4 BioPlus 50 100 E BPL0006...

Page 5: ...5 F G BPL0010 BPL0012...

Page 6: ...JP 6 BioPlus 50 100 AC A A 4 35...

Page 7: ...JP 7 B BioPlus D E B E B...

Page 8: ...JP 8 BioPlus 50 100 OASE Pump Clean F G H...

Page 9: ...JP 9 BioPlus 50 BioPlus 100 V AC 100 100 Hz 50 60 50 60 W 3 4 3 1 4 3 5 0 340 400 500 580 m 0 48 0 56 0 66 0 84 mWs 0 4 0 6 0 3 0 48 1m II...

Page 10: ...ON Only connect the unit to a correctly fitted socket Protect the plug connection from moisture Never carry or pull the unit by the electrical cable Route cables such that they are protected from dama...

Page 11: ...n cups into the mounting holes of the pump unit with a twisting movement Pay attention to the alignment of the tab it should point upwards or to the side Fasten the unit in a corner of the aquarium En...

Page 12: ...edia F Carefully pull the filter unit from the pump unit magnetic holder and remove from the aquarium Separate the filter modules press the button Empty the filter modules over a wash basin and rinse...

Page 13: ...w rate l h 340 400 500 580 F rderh he m 0 48 0 56 0 66 0 84 water column mWs 0 4 0 6 Filter volume l 0 3 0 48 SYMBOLS ON THE UNIT Submersible to 1 m depth Protection class II reliable electrical isola...