- EN -
11
Function description
B
Path of the water: Drawn in by a pump into the pump
unit, the water flows through the filter modules,
arranged above each other in stages to form the filter
unit. Each filter module is equipped with a foam filter
and/or filter fleece (top filter module). The water
enters the filter module through the inlet on the side
and exits through the small flow-out nozzles or the
central outlet, depending on the position of the
outlet control knob.
BioPlus Thermo:
The water is heated by a heater on
its way through the filter unit.
INSTALLATION AND CONNECTION
N O T E
Ensure that the pump never runs dry!
Possible consequences:
The pump will be destroyed.
Protective measure:
Regularly check the water
level
in the aquarium.
N O T E
Thoroughly rinse out all filter material with warm tap
water before using for the first time in order to
remove any soiling.
(→
Cleaning or replacing the filter
D, E, B
The supplied suction cups serve for fastening the unit
to a clean, smooth surface.
•
Push the suction cups into the mounting holes of
the pump unit with a twisting movement.
–
Pay attention to the alignment of the tab (it
should point upwards or to the side).
•
Fasten the unit in a corner of the aquarium: Ensure
that the flow-out nozzles are just below the sur-
face of the water.
COMMISSIONING/START-UP
E, B
•
Route each power connection cable such that it
forms a drip loop.
Switching on:
Connect the unit to the mains. The unit
switches on immediately. When the unit is switched
on, it takes several minutes for the air to escape from
the unit (this makes a noise).
•
Use the outlet control knob to determine which
water outlet is used (central outlet or flow-out
nozzles).
Switching off:
Disconnect the unit from the mains.
REMEDY OF FAULTS
Malfunction
Cause
Remedy
The unit does not start up
No mains voltage
Check the mains voltage.
Impeller unit blocked
Clean
Water flow insufficient
Filter housing or impeller unit soiled
Clean
Impeller unit worn
Replace impeller unit
Central outlet or flow-out nozzles soiled
Clean
Foam filter or filter fleece soiled
Clean
Insufficient filtering performance Foam filter or filter fleece soiled
Clean
Foam filter or filter fleece worn
Replace
Filter housing clogged
Clean the filter housing.
Summary of Contents for BioPlus 100
Page 1: ...BioPlus 50 100 43092_Gebrauchsanleitung_BioPlusBioPlusThermo indd 1 08 01 16 14 11...
Page 2: ...2 BioPlus 50 100 A BPL0011 B BPL0002...
Page 3: ...3 C BPL0004 D BPL0005...
Page 4: ...4 BioPlus 50 100 E BPL0006...
Page 5: ...5 F G BPL0010 BPL0012...
Page 6: ...JP 6 BioPlus 50 100 AC A A 4 35...
Page 7: ...JP 7 B BioPlus D E B E B...
Page 8: ...JP 8 BioPlus 50 100 OASE Pump Clean F G H...
Page 14: ......
Page 15: ......
Page 16: ...77391 01 20...