background image

Englis

h

 

 

 

 

Cleaning/replacing the impeller unit 

 

Remove the pump cover or pump housing from the motor housing by turning it 
counter-clockwise (bayonet catch). 

 

After removing the impeller unit, clean all parts under running tap water. 

 

Replace a worn or damaged impeller unit. 

 

Assemble in the reverse order. 

 

 

ARS0046 

 
 

Storage/winter protection 

The unit is not frost-proof and has to be removed and put into storage if minus tem-
peratures are expected. 

How to correctly store the unit: 

 

Thoroughly clean the unit, check it for damage and replace any damaged parts. 

 

Store the pump submerged and in a frost-free environment. 

 

Malfunction remedy 

 

Malfunction Possible 

cause 

Remedy 

Pump does not run 

No mains voltage 

Check the mains voltage. 

Impeller unit blocked 

Clean the impeller unit 

Insufficient delivery rate 

Impeller unit running slug-
gishly 

Clean the impeller unit 

Filter housing clogged 

Clean the filter housing. 

Pressure loss in the hose too 
high 

 

Reduce the hose length and 
connecting pieces to a mini-
mum 

 

Route hose in a straight line 

Unit switches off after a short 
running period 

Water temperature too high 

Adhere to the maximum water 
temperature of +77 °F (+35 °C) 

Unit is overloaded 

 

Remove blockage 

 

The unit will switch on 
again automatically as soon 
as it has cooled down. 

Summary of Contents for Aquarius Fountain Set Eco 250

Page 1: ...English Français Español Aquarius Fountain Set Eco 250 550 825 1100 Operating instructions Notice d emploi Instrucciones de uso ...

Page 2: ...unit Do not carry or pull the unit by its power cable Route lines in such a way that they are protected from damage and do not present a tripping hazard Protect the plug connections from moisture Do not handle plug with wet hands Grasp the plug to unplug it Do not grasp on the cable Never carry out technical changes to the unit Only carry out work on the unit that is described in this manual Alway...

Page 3: ...f a malfunction or break down the electric current is discharged through the grounding and the risk of electric shock is reduced Grounding instructions The unit is equipped with a power cord with a grounding conductor and a plug with a grounding pin The plug must be plugged into a appropriate outlet that is installed and grounded in accordance with local codes and ordinances and is pro tected by a...

Page 4: ...Y INSTRUCTIONS 2 Product Description 5 Intended use 6 Installation and connection 6 Commissioning start up 8 Maintenance and cleaning 8 Storage winter protection 9 Malfunction remedy 9 Technical data 10 Wear parts 11 Disposal 11 ...

Page 5: ...spout 5 Union nut for fastening the nozzle pipe on the branch valve 6 Nozzle pipe 7 Nozzle mount 8 Nozzle inserts Vulkan Lava Magma for different water patterns Symbols on the unit The unit is dust tight and water tight down to 6 6 ft 2 m Remove the unit in the event of freezing temperatures Danger for persons with pacemakers The unit contains a strong mag net Do not dispose of the unit with the n...

Page 6: ...ctions apply to the unit Do not use in swimming ponds Never use the unit with fluids other than water Never run the unit without water Do not use for commercial or industrial purposes Do not use in conjunction with chemicals foodstuff easily flammable or explosive substances Installation and connection Installing the water feature In addition to the water feature you can connect a rivulet or water...

Page 7: ...ectrocution Install the unit at a distance of at least 2 m from the water to ensure that it is pro tected against flooding Ensure that the connection to the power supply is at least 6 6 ft from the pond Place the pump horizontally on a stable mud free surface The pump is under water the nozzle intake emerges from the water TIP Thoroughly clean the pond or pool and place the pump approx 200 mm abov...

Page 8: ...n immediately Switching off Pull the power plug from the outlet Maintenance and cleaning NOTE Never use chemical cleaning agents These are hazardous to animals plants and the environment Only use clear water and a soft brush to clean the unit Recommendation regarding cleaning Clean the unit as required but at least twice a year When cleaning the pump pay particular attention to the impeller unit a...

Page 9: ...e any damaged parts Store the pump submerged and in a frost free environment Malfunction remedy Malfunction Possible cause Remedy Pump does not run No mains voltage Check the mains voltage Impeller unit blocked Clean the impeller unit Insufficient delivery rate Impeller unit running slug gishly Clean the impeller unit Filter housing clogged Clean the filter housing Pressure loss in the hose too hi...

Page 10: ...er column ft 4 2 6 9 8 5 9 8 mwc 1 3 2 1 2 6 3 0 Max pump immersion depth m 2 2 2 2 ft 6 56 6 56 6 56 6 56 Water feature connection in 1 1 1 1 Stepped hose adapter in 1 1 1 1 Dimensions Length in 8 1 8 1 8 1 8 1 Width in 7 1 7 1 7 1 7 1 Height in 5 5 5 5 5 5 5 5 Weight kg 1 8 1 8 2 0 2 2 lbs 4 0 4 0 4 4 4 9 Permissible water values Fresh water pond water pH value 6 8 8 5 Hardness ppm 0 45 0 48 dH ...

Page 11: ...11 Wear parts Impeller unit Disposal NOTE Do not dispose of this unit with household waste Dispose of the unit by using the return system provided for this purpose Render the unit unusable by cutting the cables ...

Page 12: ...ARS0047 ...

Page 13: ...OASE North America Inc 330 274 8317 www atlantic oase com 77950 08 20 ...

Reviews: