background image

Englis

h

 

 

 

 

 

WARNING 

Serious injury or death due to dangerous electrical voltage is possible with an electri-
cal device in water operated with a voltage U > 12 V AC or U > 30 V DC. 

 

Disconnect the unit from the mains before reaching into the water. 

 

Disconnect the unit from the mains before you start working on it. 

 

 

 

WARNING 

There is a risk of electric shock if the unit's grounding conductor is not connected 
properly. 

The unit must be grounded to ensure that in the event of a malfunction or break-
down, the electric current is discharged through the grounding and the risk of electric 
shock is reduced. 

Grounding instructions: 

 

The unit is equipped with a power cord with a grounding conductor and a plug 
with a grounding pin. The plug must be plugged into a appropriate outlet that is 
installed and grounded in accordance with local codes and ordinances and is pro-
tected by a ground circuit interrupter (GFCI). 

 

Do not modify the plug. If the plug does not fit into the outlet, consult a qualified 
electrician for installation of a proper outlet. 

 

Check with a qualified electrician if you are in doubt as to whether the unit is 
properly grounded. 

 

 

 

 

 

 
 

Summary of Contents for Aquarius Fountain Set Eco 1100

Page 1: ...English Fran ais Espa ol Aquarius Fountain Set Eco 250 550 825 1100 Operating instructions Notice d emploi Instrucciones de uso...

Page 2: ...nit Do not carry or pull the unit by its power cable Route lines in such a way that they are protected from damage and do not present a tripping hazard Protect the plug connections from moisture Do no...

Page 3: ...a malfunction or break down the electric current is discharged through the grounding and the risk of electric shock is reduced Grounding instructions The unit is equipped with a power cord with a gro...

Page 4: ...INSTRUCTIONS 2 Product Description 5 Intended use 6 Installation and connection 6 Commissioning start up 8 Maintenance and cleaning 8 Storage winter protection 9 Malfunction remedy 9 Technical data 1...

Page 5: ...pout 5 Union nut for fastening the nozzle pipe on the branch valve 6 Nozzle pipe 7 Nozzle mount 8 Nozzle inserts Vulkan Lava Magma for different water patterns Symbols on the unit The unit is dust tig...

Page 6: ...tions apply to the unit Do not use in swimming ponds Never use the unit with fluids other than water Never run the unit without water Do not use for commercial or industrial purposes Do not use in con...

Page 7: ...ctrocution Install the unit at a distance of at least 2 m from the water to ensure that it is pro tected against flooding Ensure that the connection to the power supply is at least 6 6 ft from the pon...

Page 8: ...immediately Switching off Pull the power plug from the outlet Maintenance and cleaning NOTE Never use chemical cleaning agents These are hazardous to animals plants and the environment Only use clear...

Page 9: ...any damaged parts Store the pump submerged and in a frost free environment Malfunction remedy Malfunction Possible cause Remedy Pump does not run No mains voltage Check the mains voltage Impeller uni...

Page 10: ...r column ft 4 2 6 9 8 5 9 8 mwc 1 3 2 1 2 6 3 0 Max pump immersion depth m 2 2 2 2 ft 6 56 6 56 6 56 6 56 Water feature connection in 1 1 1 1 Stepped hose adapter in 1 1 1 1 Dimensions Length in 8 1 8...

Page 11: ...1 Wear parts Impeller unit Disposal NOTE Do not dispose of this unit with household waste Dispose of the unit by using the return system provided for this purpose Render the unit unusable by cutting t...

Page 12: ...ARS0047...

Page 13: ...OASE North America Inc 330 274 8317 www atlantic oase com 77950 08 20...

Reviews: