Commissioning/start-up 

NOTE 

Never connect the pump to a dimmer. Otherwise the pump will be destroyed. 

Switching on:

 Plug the power plug into the outlet. 

The unit switches on immediately. 

Switching off:

 Pull the power plug from the outlet. 

Maintenance and cleaning 

NOTE 

Never use chemical cleaning agents. These are hazardous to animals, plants and the 

environment. 

Only use clear water and a soft brush to clean the unit. 

Recommendation regarding cleaning: 

Clean the unit as required, but at least twice a year. 

When cleaning the pump, pay particular attention to the impeller unit and the

pump housing. 

Opening/closing the housing 

Before closing the housing, place the power cable in the recess in the housing to pre-
vent it from being crushed. 

Opening the housing 

Closing the housing 

ARS0041

ARS0042

Downloaded from http://www.watergardeningdirect.com

Summary of Contents for Aquarius Fountain Set Classic 1000

Page 1: ...Aquarius Fountain Set Classic 750 1000 2000 3000 4000 Operating instructions Downloaded from http www watergardeningdirect com...

Page 2: ...A ARS0055 B ARS0039 Downloaded from http www watergardeningdirect com...

Page 3: ...nit can be used by children aged 8 and above and by persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on h...

Page 4: ...emakers or implantable cardioverter defibrillators ICDs Keep a distance of at least 0 2 m between the implant and the magnet Do not carry or pull the unit by its power cable Route lines in such a way...

Page 5: ...ot dispose of the unit with the normal household waste Read the operating instructions Installing the pump WARNING Death or serious injuries from hazardous electrical voltage due to operation of this...

Page 6: ...to animals plants and the environment Only use clear water and a soft brush to clean the unit Recommendation regarding cleaning Clean the unit as required but at least twice a year When cleaning the p...

Page 7: ...ace a worn or damaged impeller unit Assemble in the reverse order ARS0043 Storage winter protection The unit is not frost proof and has to be removed and put into storage if minus tem peratures are ex...

Page 8: ...will switch on again automatically as soon as it has cooled down The water pattern is uneven or incomplete Nozzle is blocked Clean nozzle Technical data Unit data Aquarius Fountain Set Eco 750 1000 2...

Page 9: ...parts The use of original parts from OASE ensures continued safe and reliable operation of the unit Please visit our website for spare parts drawings and spare parts www oase com ersatzteile Disposal...

Page 10: ...ASE GmbH Postfach 2069 48469 H rstel Tecklenburger Stra e 161 48477 H rstel Germany www oase com info oase com Hotline 49 5454 93 39 49 20 77949 08 20 Downloaded from http www watergardeningdirect com...

Reviews: