Safety information 

Electrical connection 

Only connect the unit if the electrical data of the unit and the power supply match. 

Only plug the unit into a correctly installed outlet. Ensure that the outlet is fused 

for a rated fault current of max. 30 mA by means of a fault current protection de-

vice. 

Protect the plug connections from moisture. 

Safe operation 

Do not use the unit, if electrical lines or the housing are damaged. 

A damaged connection cable cannot be replaced. Dispose of the unit. 

The impeller unit in the pump contains a magnet with a strong magnetic field that 
may affect the operation of pacemakers or implantable cardioverter defibrillators 

(ICDs). Keep a distance of at least 0.2 m between the implant and the magnet. 

Do not carry or pull the unit by its power cable. 

Route lines in such a way that they are protected from damage and do not present
a tripping hazard. 

Should problems occur, please contact the authorised customer service or OASE. 

Product Description 

Overview 

 A 

1

Filter housing with filter pump

Transition piece, fastens the filter pump to the filter cover 

3

Branch valve with flow-rate regulators

4

Stepped hose adapter 13/19/25 mm for connection of a rivulet or waterspout

Union nut for fastening the nozzle pipe on the branch valve 

6

Nozzle pipe

7

Nozzle mount

Nozzle inserts (Vulkan, Lava, Magma) for different water patterns 

Downloaded from http://www.watergardeningdirect.com

Summary of Contents for Aquarius Fountain Set Classic 1000

Page 1: ...Aquarius Fountain Set Classic 750 1000 2000 3000 4000 Operating instructions Downloaded from http www watergardeningdirect com...

Page 2: ...A ARS0055 B ARS0039 Downloaded from http www watergardeningdirect com...

Page 3: ...nit can be used by children aged 8 and above and by persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on h...

Page 4: ...emakers or implantable cardioverter defibrillators ICDs Keep a distance of at least 0 2 m between the implant and the magnet Do not carry or pull the unit by its power cable Route lines in such a way...

Page 5: ...ot dispose of the unit with the normal household waste Read the operating instructions Installing the pump WARNING Death or serious injuries from hazardous electrical voltage due to operation of this...

Page 6: ...to animals plants and the environment Only use clear water and a soft brush to clean the unit Recommendation regarding cleaning Clean the unit as required but at least twice a year When cleaning the p...

Page 7: ...ace a worn or damaged impeller unit Assemble in the reverse order ARS0043 Storage winter protection The unit is not frost proof and has to be removed and put into storage if minus tem peratures are ex...

Page 8: ...will switch on again automatically as soon as it has cooled down The water pattern is uneven or incomplete Nozzle is blocked Clean nozzle Technical data Unit data Aquarius Fountain Set Eco 750 1000 2...

Page 9: ...parts The use of original parts from OASE ensures continued safe and reliable operation of the unit Please visit our website for spare parts drawings and spare parts www oase com ersatzteile Disposal...

Page 10: ...ASE GmbH Postfach 2069 48469 H rstel Tecklenburger Stra e 161 48477 H rstel Germany www oase com info oase com Hotline 49 5454 93 39 49 20 77949 08 20 Downloaded from http www watergardeningdirect com...

Reviews: