Electrical Shock Hazard. To reduce the risk of electric shock, always disconnect the table from the electrical outlet 

before moving the table or doing any maintenance or troubleshooting procedures. 

  • 

The power supply/control module is located at the head end of the table. Refer servicing to qualified personnel and  

follow manual instructions when doing any authorized troubleshooting. Before doing any work on the unit, disconnect the power 

cord from the power outlet.

  •  Do not operate the table in standing water.
  •  Before moving the table, turn accessory controls off, disconnect the power cord from the power outlet and secure the electrical 

cord, hand control and foot controls out of the way  for moving.

  •  Use this furnishing only for its intended use as described in these instructions. Do not use attachments not recommended by 

the manufacturer.

  •  Never operate this table if it has a damaged cord or plug., if it is not working properly, if it has been dropped or damaged, or dropped 

into water. Return the furnishing to a service center for examination and repair.

  •  Keep the cord away from heated surfaces.
  •  Do not  use outdoors.
  •  Do not operate where aerosol (spray) products are being used or whereoxygen is being administered.
  •  Risk of Injury — Keep children from moving headrest and foot support. Children should never be near the table when in use. This table 

must be locked out (use key lock) and controls stored out of reach if there is any possibility that children would be near the table when not 
in use.

  •  Never drop or  insert any object into any opening.
  •  This product is equipped with an interior accessory outlet. The total electrical load of equipment plugged into this set of outlets is not 

to exceed 7 amps or 840 watts. Voltage will be different for other counties.

WARNING

DANGER

  Prior to moving the table, bring table top to its lowest position.

•  

DO NOT sit on the Arm Rests, the elevated Back Rest or Leg Rest. 

DO NOT place excess weight on the Side Arm Rests. DO NOT use them in assisting the client on and off the table. 

•  

DO NOT put excessive weight or pressure on the QuickLock

 Face Rest. Excessive pressure can cause premature failure of 

the QuickLock

 Face Rest. Do Not extend the dowels of the Face Rest further than 3” from the table edge to ensure a stable 

connection.

•  

DO NOT use the hand control and the foot control simultaneously as this can cause damage to one or both units. 

•  DO NOT store or place anything on the cabinet hood under the backrest as this can cause damage to top 

and/or hood 

and will void the warranty.

•  

Maximum Working Load Rating (client and accessories):  500lbs. (227 kg)

• Maximum shelf load weight: 200 lbs. (91 kg)

  •To reduce the risk of electric shock always unplug this table from the electric outlet before

 cleaning. 

  •Risk of Electrical Shock. — Connect this table to a properly grounded outlet only. See Grounding Instructions.

IMPORTANT SAFETY INSTRUCTIONS

Summary of Contents for Celesta

Page 1: ...Clodagh Gemini Celesta Celesta and Clodagh Gemini USER MANUAL www OAKWORKS com 717 235 6807 made in the USA with US imported parts...

Page 2: ...within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifications and the like documen...

Page 3: ...Section Salon Top and Flat Top Tables Only 8 Table Keyswitch 8 Under Table Cabinet 9 Important Safety Note 9 Moving the Table 10 Table Extender 10 Arm Rest Installation and Adjustment Instructions 11...

Page 4: ...children DO NOT allow children to crawl into the cabinet or under the table The moving mechanism parts of this table may result in pinching or entrapment of hands or feet It is the respon sibility of...

Page 5: ...se This table must be locked out use key lock and controls stored out of reach if there is any possibility that children would be near the table when not in use Never drop or insert any object into an...

Page 6: ...n here with QuickLock Face Rest and Boiance Crescent 3 PRODUCT DESCRIPTION TABLE SPECIFICATIONS Height 25 37 64 cm 94 cm Width 29 74 cm 31 79 cm Length 73 185 cm Lift Capacity 500 lbs 227 kg Maximum W...

Page 7: ...Flat Top model shown here with QuickLock Face Rest and Boiance Crescent 4 TABLE SPECIFICATIONS Height 25 37 64 cm 94 cm Width 29 74 cm 31 79 cm Length 73 185 cm Lift Capacity 500 lbs 227 kg Maximum Wo...

Page 8: ...is equipped with a cord having an equipment grounding conductor and a ground ing pin The pin must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all...

Page 9: ...accessory outlet The total electrical load of equipment plugged into this set of outlets is not to exceed 7 amps or 840 watts Voltage will be different for other counties DANGER This product offers an...

Page 10: ...staying parallel to the floor no matter what the position Backrest UP Backrest DOWN Footrest UP Footrest DOWN Table UP Table DOWN Press and hold the appropriate button until the position desired is a...

Page 11: ...rgonomics while staying parallel to the floor no matter what the position Backrest UP Backrest DOWN Footrest UP Footrest DOWN Table UP Table DOWN A table keyswitch is located inside the cabinet on the...

Page 12: ...the backrest and can cause damage to the table or the object Using this area as storage will void the warranty Not for Storage To Access the Storage in the Under Table Cabinet The table has a fully in...

Page 13: ...for moving a table of this size to prevent injury to yourself or the table We strongly recommend that a flatbed dolly be used that can hold the entire table if moving the table involves any large dis...

Page 14: ...on s weight when getting on or off the table The arm rest height is adjusted to level at the factory When in use some of the new parts will wear and you may see some sagging of the arm rest over time...

Page 15: ...cam lock within 3 of the table to ensure a stable con nection The recommended length of dowel bracing against the backrest should be at least 2 inches To remove the QuickLock Face Rest just pull the f...

Page 16: ...er plated metals 2 Clorox Hydrogen Peroxide Disinfectant EPA reg 67619 24 corrosion of metals deterioration of upholstery and wood lacquer leaves a hard to remove residue 3 Virox Accel TB EPA reg 7455...

Page 17: ...ain wet for the disinfectant manufacturer s recommended contact time 4 Throw the used wipe s away and allow the table to dry INSPECTIONS RECOMMENDED REGULAR INSPECTIONS monthly or local standard Check...

Page 18: ...t section Serial Number 16796025 GNCDES312572ACTTVFN6 Ser GMC563146 Clodagh Gem E Salon 31 x 25 37 x 72 ACTTVFN6TT TTButter 01 04 2013 Order 654321 Notes Sample Product Label Model Numbers and Serial...

Page 19: ...S Length 73 185cm Width 29 31 74cm 79cm Height Range 25 37 64 94cm Weight 300 lbs 136 kg Shipping Weight 375 lbs 170 kg Shipping Crate Dimensions 81 L x 36 H x 35 W 205 7cm x 91 4cm x 89cm Cabinet Dim...

Page 20: ...PA 17349 Phone 717 235 6807 FAX 717 235 6798 www oakworks com 3034177 CONFORMS TO UL STD 962 Certified to CAN CSA STD C22 2 68 USER MANUAL Original Instructions Manual Part Number MMMNST0030 EN Revisi...

Reviews: