background image

OPTIONAL ACCESSORY AVAILABLE ON SALON TOP ONLY

Manicure Arm Rests

Adjustable Side Arm Rests

1. Insert end of arm rest into 

hole in backrest while holding 

arm rest at 60° angle.

2. Push end all the way into hole and drop arm rest into horizontal 

position. Tug slightly to make sure the armrest is fully locked to 

the table (for patient safety).

To remove the arm rest, simply reverse the procedure above.

TO INSTALL THE ARM REST:

The arm rests adjust automatically as the table’s back support moves to remain parallel to the floor in any position. 

They are designed to be strong and will take a reasonable amount of weight, but they are not designed to be used to 

sustain a person’s weight when getting on or off the table.

The arm rest height is adjusted to level at the factory. When in use, 

some of the new parts will wear, and you may see some sagging of the 

arm rest over time. If the arm rest is not correct, the height can easily be 

adjusted using the enclosed Allen wrench.

1. Loosen bottom 2 set screws  

(turn counter-clockwise).

2. Turn side set screw in (clock-

wise to rase or counter-clockwise 

to lower) while lightly raising the 

arm rest with your other hand (to 

make the adjustment easier).

3. When you have achieved 

the desired height, tighten 

the two bottom set screws 

(turn clockwise).

TO LEVEL THE ARM REST:

Do not use the arm rest for customer weight support during the mounting or 

dismounting of the table. The arm rest is not designed to support the client’s 

weight.

CAUTION

DIRECTIONS FOR USE

ARM REST INSTALLATION AND ADJUSTMENT INSTRUCTIONS

11

Summary of Contents for Celesta

Page 1: ...Clodagh Gemini Celesta Celesta and Clodagh Gemini USER MANUAL www OAKWORKS com 717 235 6807 made in the USA with US imported parts...

Page 2: ...within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifications and the like documen...

Page 3: ...Section Salon Top and Flat Top Tables Only 8 Table Keyswitch 8 Under Table Cabinet 9 Important Safety Note 9 Moving the Table 10 Table Extender 10 Arm Rest Installation and Adjustment Instructions 11...

Page 4: ...children DO NOT allow children to crawl into the cabinet or under the table The moving mechanism parts of this table may result in pinching or entrapment of hands or feet It is the respon sibility of...

Page 5: ...se This table must be locked out use key lock and controls stored out of reach if there is any possibility that children would be near the table when not in use Never drop or insert any object into an...

Page 6: ...n here with QuickLock Face Rest and Boiance Crescent 3 PRODUCT DESCRIPTION TABLE SPECIFICATIONS Height 25 37 64 cm 94 cm Width 29 74 cm 31 79 cm Length 73 185 cm Lift Capacity 500 lbs 227 kg Maximum W...

Page 7: ...Flat Top model shown here with QuickLock Face Rest and Boiance Crescent 4 TABLE SPECIFICATIONS Height 25 37 64 cm 94 cm Width 29 74 cm 31 79 cm Length 73 185 cm Lift Capacity 500 lbs 227 kg Maximum Wo...

Page 8: ...is equipped with a cord having an equipment grounding conductor and a ground ing pin The pin must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all...

Page 9: ...accessory outlet The total electrical load of equipment plugged into this set of outlets is not to exceed 7 amps or 840 watts Voltage will be different for other counties DANGER This product offers an...

Page 10: ...staying parallel to the floor no matter what the position Backrest UP Backrest DOWN Footrest UP Footrest DOWN Table UP Table DOWN Press and hold the appropriate button until the position desired is a...

Page 11: ...rgonomics while staying parallel to the floor no matter what the position Backrest UP Backrest DOWN Footrest UP Footrest DOWN Table UP Table DOWN A table keyswitch is located inside the cabinet on the...

Page 12: ...the backrest and can cause damage to the table or the object Using this area as storage will void the warranty Not for Storage To Access the Storage in the Under Table Cabinet The table has a fully in...

Page 13: ...for moving a table of this size to prevent injury to yourself or the table We strongly recommend that a flatbed dolly be used that can hold the entire table if moving the table involves any large dis...

Page 14: ...on s weight when getting on or off the table The arm rest height is adjusted to level at the factory When in use some of the new parts will wear and you may see some sagging of the arm rest over time...

Page 15: ...cam lock within 3 of the table to ensure a stable con nection The recommended length of dowel bracing against the backrest should be at least 2 inches To remove the QuickLock Face Rest just pull the f...

Page 16: ...er plated metals 2 Clorox Hydrogen Peroxide Disinfectant EPA reg 67619 24 corrosion of metals deterioration of upholstery and wood lacquer leaves a hard to remove residue 3 Virox Accel TB EPA reg 7455...

Page 17: ...ain wet for the disinfectant manufacturer s recommended contact time 4 Throw the used wipe s away and allow the table to dry INSPECTIONS RECOMMENDED REGULAR INSPECTIONS monthly or local standard Check...

Page 18: ...t section Serial Number 16796025 GNCDES312572ACTTVFN6 Ser GMC563146 Clodagh Gem E Salon 31 x 25 37 x 72 ACTTVFN6TT TTButter 01 04 2013 Order 654321 Notes Sample Product Label Model Numbers and Serial...

Page 19: ...S Length 73 185cm Width 29 31 74cm 79cm Height Range 25 37 64 94cm Weight 300 lbs 136 kg Shipping Weight 375 lbs 170 kg Shipping Crate Dimensions 81 L x 36 H x 35 W 205 7cm x 91 4cm x 89cm Cabinet Dim...

Page 20: ...PA 17349 Phone 717 235 6807 FAX 717 235 6798 www oakworks com 3034177 CONFORMS TO UL STD 962 Certified to CAN CSA STD C22 2 68 USER MANUAL Original Instructions Manual Part Number MMMNST0030 EN Revisi...