background image

Cap Lock

Clip

Battery Lid

Lift the clip to unlock

4×AAA

Batteries

Push the clip to open the battery lid

www.coleparmer.com

 

 

 

Ordering Information

 

Model 

Product description 

CT

S

1  

EcoTestr pocket   

conductivity

/

T

DS/

salinity tester 

 

 

 

Conductivity 

Range 

0~

2

00

.

0

µ

S/

cm,   

0~

2

000

µ

S/

cm, 

0~

2

0

.

00

m

S/

cm 

Resolution 

0

.1

/

S/

cm

0

.

0

1 m

S/

cm 

Accuracy 

±1%F

S

 

Calibration points 

1

~

2 points; auto standard 

recognition 

Automatic temperature 

compensation 

3 to 122

0~

5

0

 

 

T

DS

 

Range 

0~

1

00

.

0

ppm,   

0~

1

000

ppm, 

0~

1

0

.

00

ppt 

Accuracy 

±1%F

S

 

Automatic temperature 

compensation 

32 to 122

0~

5

0

 

 

S

alinity 

Range 

0~

1

0

.

00

ppt

ppm

 

Accuracy 

±1%F

S

 

Automatic temperature 

compensation 

32 to 122

0~

5

0

 

 

Temperature 

Range 

32 to 122

0~

5

0

 

 

Resolution 

0

.1

/

 

Accuracy 

±

0

.9

0

.5

 

 

10650101_MAN_CTS1_35462-11

March 2021

+

-

+

-

+

-

+

-

Power: 

four AAA batteries (included); >400 hours of continuous 

operation 

Low-voltage warning:

        battery status icon flashes 

Auto power-off: 

tester automatically turns off after 8 minutes of 

nonuse 

IP rating: 

IP67 (waterproof), floats on water when sensor cap is on 

Dimensions (L x W x H): 

7" x 1.5" x 1.25" (17.8 x 4 x 3.1 cm)

Weight: 

3.8 oz (107 g)

Battery Installation 

The tester uses four AAA batteries. Please install batteries 

according to the following steps. Note the correct direction of battery 

installation: the positive side (+) of every single battery must face 

up. Incorrect installation of batteries will cause damage to the tester 

and create a potential hazard. 

1. Pull the battery cap up.

2. Slide the battery cap along the direction of arrow. 
3. Open the battery cap. 

4. Insert the batteries 

(ALL POSITIVE SIDES FACING UP).

 

5. Close the battery cap. 

6. Slide and lock the battery cap along the direction of arrow. 

7. Fit the tester’s cap while making sure to push all the way down. 

The tester’s waterproof design may be compromised if the cap is 

not fitted correctly. 

Warranty 

We warrant this instrument to be free from defects in material and 

workmanship and agrees to repair or replace free of charge, at 

option of Oakton Instruments, any malfunctioned or damaged 

product attributable to responsibility of Oakton Instruments, for a 

period of

 two years

 from the delivery (a 

six-month

 limited warranty 

applies to probes). This warranty does not apply to defects resulting 

from actions such as misuse (violation of the instructions in this 

manual or operations in the manner not specified in this manual), 

improper maintenance, and unauthorized repairs. Warranty period is 

the time limit to provide free service for the products purchased by 

customers, not the service life of the tester or probe. 

Oakton Instruments reserves the right to update the information in 

this manual without giving notice in advance. 

Specification

35462-11

Catalog 

number

00653-18

 00606-10


1413 μS Conductivity Standard 500 mL

12.88 mS conductivity standard 500 mL