background image

WARNING

WHEN CONNECTING FOR USE:

Use only in compliance with applicable codes.

Read and follow the manufacturer's instructions.

Be sure the regulator vent is not pointing up.

Turn off all of the valves on the appliance.

Do not use, store or transport cylinder where it 
would be exposed to high temperatures.  Relief 
valve may open allowing a large amount of 
flammable gas to escape.

When transporting, keep cylinder secured in an 
upright position with cylinder valve turned off.

DO NOT REMOVE, DEFACE, OR OBLITERATE THIS LABEL

*EXCEPT AS AUTHORIZED BY ANSI/NFPA 58.

DANGER!

  Do not store a spare LP cylinder under or near a barbeque, or other heat sources.

Never fill an LP cylinder beyond 80% full, a fire causing death or serious injury may occur.

Page 6

LP-gas is heavier than air and may settle in low 
places while dissipating.

Do not check for gas leaks with a match or an open 
flame.  Apply soapy water to areas marked "X".  
Open cylinder valve. If bubble appears, close valve 
and have LP-gas service person make needed 
repairs. Also check appliance valves and 
connections to make sure they do not leak before 
lighting appliance,

Contact with the liquid contents of the cylinder 
will cause freeze burns to the skin

Do not allow children to tamper or play with 
cylinder.

Light appliance(s) following manufacturer's 
instructions.

When not connected for use, keep cylinder valve 
turned off.  Self contained appliances shall be 
limited to a cylinder of 30 lb. capacity or less.

When appliance is not in use, keep the cylinder 
valve closed.

DANGER 

- FLAMMABLE GAS UNDER PRESSURE

LEAKING LP-GAS MAY CAUSE A FIRE OR EXPLOSION IF IGNITED

CAUSING SERIOUS BODILY INJURY OR DEATH.

CONTACT LP GAS SUPPLIER FOR REPAIRS, OR DISPOSAL OF

THIS CYLINDER OR UNUSED LP-GAS.

WARNING

 - FOR OUTDOOR USE ONLY*

DO NOT USE OR STORE CYLINDER IN A BUILDING, GARAGE

OR ENCLOSED AREA.

Know the odor of LP-gas.  If you hear, see or smell 
leaking LP-gas, immediately get everyone away 
from the cylinder and call the Fire Department.  Do 
not attempt repairs.

Consult manufacturer's instructions concerning 
the cylinder connection provided with your 

Caution your LP-gas supplier to

Be certain cylinder is purged of trapped air prior to 
first filling.
Be certain not to over fill the cylinder.
Be certain cylinder requalification date is checked.

Summary of Contents for CASUAL FIRESIDE Basso 5150-36RDC

Page 1: ...ues leave the area immediately 4 After leaving the area call your gas supplier or fire department 2 Extinguish any open flame DANGER A HIGHER STANDARD IN QUALITY AND APPEARANCE SAFE AND BEAUTIFUL OUTD...

Page 2: ...ONLY THIS UNIT MUST BE INSTALLED AT LEAST 60 FROM CENTER OF BURNER TO ANY COMBUSTIBLE WALLS CEILINGS OR MATERIAL WHEN SHUTTING OFF THE UNIT BE SURE TO TURN THE CONTROL VALVE ON THE FIRE PIT TO THE FU...

Page 3: ...d to use may not be the same that your fire pit was setup for or is stated on your outdoor rating plate THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE GAS If the gas supply is different or you wish...

Page 4: ...ing put into operation if it is evident that the burner is damaged Replacement burner COM0590A manufactured by O W Lee Company 1206 Fifth Street Comfort TX 78013 M DO NOT store any combustible materia...

Page 5: ...o be used must be provided with a listed overfilling prevention device OPD and with a cylinder connection device compatible with the connection for the appliance 3 Make sure the appliance is NOT in us...

Page 6: ...ves and connections to make sure they do not leak before lighting appliance Contact with the liquid contents of the cylinder will cause freeze burns to the skin Do not allow children to tamper or play...

Page 7: ...on the surface and all four sides as shown above Page 7 REPLACEMENT PARTS AND MEDIA ARE AVAILABLE THROUGH YOUR LOCAL DEALER 1 Stainless Steel X Burner 2 Propane Regulator 3 On Off Control Knob 4 Bras...

Page 8: ...e to expand and cause a pop and launch outside of the fire pit which could cause injury or property damage Allow lava granules to completely dry after getting wet rained on or hosed off before lightin...

Page 9: ...WILL REMAIN HOT FOR SOME TIME AFTER USE YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT...

Page 10: ...ferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctl...

Page 11: ...ions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor...

Page 12: ...the propane tank valve is closed 2 Wait a minimum of 5 minutes for the gas to clear out OPERATING INSTRUCTIONS We recommend that before you install your Fire Pit you familiarize yourself with the con...

Page 13: ...for various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemicals...

Page 14: ...nd replace it with the proper sized one for your gas requirement Propane requires the smaller orifice 4 If you are converting from propane LP gas to natural gas install the air shutter sleeve so that...

Page 15: ...ppelez votre fournisseur de gaz ou le service d incendie DANGER Cet appareil gaz est con u comme un appareil surveill Les adultes doivent tre pr sents lorsque l unit est en fonctionnement en train de...

Page 16: ...TOUT MURS PLAFONDS OU MAT RIAUX COMBUSTIBLES LORSQUE VOUS TEIGNEZ L APPAREIL VEILLEZ COMMANDER LA VANNE DE CONTR LE DU PUITS D INCENDIE LA POSITION TOTALE DE L ALLUMAGE ET DE FERMER LA VANNE SUR LE R...

Page 17: ...ajustement de l entr e est de 127 mm 3 5 pouces de colonne d eau WC Water Column et la pression maximale d admission est de 254 mm 10 pouces WC POUR LE PROPANE La pression minimale d admission du gaz...

Page 18: ...EUNES ENFANTS DOIVENT TOUJOURS TRE SOIGNEUSEMENT SUPERVIS S LORSQU ILS SE TROUVENT DANS LA ZONE DE CET APPAREIL ET QU IL EST EN UTILISATION DES BLESSURES GRAVES OU LA MORT PEUVENT AVERTISSEMENT Ne jet...

Page 19: ...e munie d un dispositif de pr vention de trop plein OPD r pertori et d un dispositif de connexion de bouteille compatible avec le raccordement de l appareil 3 Assurez vous que l appareil n est PAS uti...

Page 20: ...ne fuient pas avant d allumer l appareil Le contact avec le liquide contenu dans la bouteille provoquera des br lures de la peau dues au gel Ne laissez pas les enfants alt rer ou jouer avec le cylind...

Page 21: ...naturel n 9 cran de protection n 10 Thermocouple 10 n 11 Granules de lave n 12 Kit de verre Pebble Taille 3 4 1 2 9 19mm n 13 Trousse de vitre coupe feu concass e Taille 1 2 3 4 12 20 mm n 14 Kit de...

Page 22: ...s ou des dommages mat riels Laissez les granules de lave s cher compl tement apr s avoir t mouill es avant de les allumer et en utilisant le foyer Page 8 cran protecteur PLACEMENT DE SUPPORTS EN VERRE...

Page 23: ...rovoquer une expansion des gaz pi g s ou de l humidit et provoquer un clatement et un lancement pourrait causer des blessures ou des dommages mat riels Laissez les granules de lave s cher compl tement...

Page 24: ...ans le venturi et orifices des trous pour d gager le passage libre des toiles d araign es ou d autres d bris Assurez vous de tout remettre correctement lorsque vous avez termin pour le fonctionnement...

Page 25: ...ant Parties Pit Fire O W Lee offre une garantie limit e de deux 2 ans sur tous les composants du br leur en utilisation normale et appropri e entretien OW Lee sera l usine de r parer ou de remplacer t...

Page 26: ...ande du foyer et la soupape du r servoir de propane sont ferm es 2 Attendez au moins 5 minutes que le gaz se vide MODE D EMPLOI Nous vous recommandons de vous familiariser avec le sch ma de la vanne d...

Page 27: ...ue r pertori de la Proposition 65 La combustion de propane dans des appareils tels que des po les ou des syst mes de chauffage et des v hicules utilisant du propane cr e des produits chimiques nocifs...

Page 28: ...ce que les orifices d admission d air soient ferm s Figure 2 Pour le gaz propane retirez l obturateur d air de fa on ce que les orifices d admission d air soient ouverts Figure 1 Une fois que l unit e...

Reviews: