SAFETY NOTE:  An secondary on/off valve, kept in the Off Position, in a fixed piping gas supply line before the fire pit 
is required for safety when your Outdoor Fire Pit is not in use.  It also provides for convenient maintenance and 
repair.

O.

D.

E.

Casual Fireside Fire Pits are suitable for installation from 0 - 4,500 ft. elevation without modification.

M.

F. Fixed Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (BTU/hr).  Undue 

pressure loss will occur if the pipe is too small or the run is too long.

GAS PRESSURE REQUIREMENTS:

FOR NATURAL GAS: 

 The minimum inlet gas supply pressure for purposes of input adjustment is 

3.5 inches

 (88.9 mm) water 

column and maximum inlet gas supply pressure is 

10.5 inches

 (266.7 mm) water column.

FOR PROPANE: 

 The minimum inlet gas supply pressure for purposes of input adjustment is 

8 inches

(203 mm) water column and the maximum inlet gas supply pressure is 

13 inches

 (330 mm) water column.

MANIFOLD PRESSURE REQUIREMENT:

   Liquid Propane 9.5 (241.3mm)  / Natural Gas 2.5 (63.5mm) of pressure.

DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED.

A. Before installing the Outdoor Fire Pit, check “Minimum Clearance to Combustibles” on page 2.

MINIMUM CLEARANCES

 must be maintained when you install this Outdoor Fire Pit.  

THERE  MUST

BE AT LEAST 60”

 (1.5 m) from the center of the burner to any combustible sidewall, ceiling, or material.  

The Outdoor Fire Pit is for outdoor use only.  DO NOT install or use this appliance inside a building,
garage, or any other enclosed area or structure including recreational vehicles, boats & sheds.  

This unit must be

installed in such a manner that proper air ventilation is maintained without obstruction at all times, and during all 
weather conditions. 

B.

C.

CHECK GAS TYPE

 (Natural Gas or Propane):  The gas supply you intend to use may not be the same that your fire pit was 

setup for or is stated on your outdoor rating plate.  

THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE

 

GAS

.  If 

the gas supply is different, 

or you wish to change to Natural Gas, you MUST have the Fire Pit Converted (directions to 

convert can be found on page 12) to the gas type you intend to use.  Any gas type conversion should be performed 
by a qualified, professional technician or licensed plumber

.  If you are unsure, contact your dealer for assistance.

INSTALLER NOTE:  This unit should be installed so that it can be removed at a later date for service.

K.

Propane Regulator Hose 

(when used):   The propane regulator hose is located inside the fire pit door panel.  When 

installed, make sure the hose is secured inside the unit and 

DOES NOT TOUCH THE BURNER PAN.

L.

Propane Regulator Hose:

  Always inspect the condition of the propane regulator hose before each operation.  Any signs of 

excessive abrasion the hose MUST BE REPLACED.  Contact your local dealer for replacement part #COM0589

If the Outdoor Fire Pit is connected to a fixed piping gas supply line, the supply line is required to have an on/off gas valve 
installed before the fire pit must be closed during any pressure testing of the system at test pressures equal to or less than ½ 
psi (3.5kPa).

I.

N.

IMPORTANT SAFETY INFORMATION 

Pre-Installation & Preparation Guidelines

If the Outdoor Fire Pit is connected to a fixed piping gas supply line, the supply line is required to have an on/off gas valve 
installed before the fire pit and it must be closed during any pressure testing of the system at test pressures in excess of ½ 
psi (3.5kPa).  

G.

H.

DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT OR EXCEEDS THE MAXIMUM.

J.

Note:  The Use Of A Third Party Fire Pit Top, Media and or Components Will Void the Omni Certification
and O.W Lee Warranty. 

GAS SUPPLY PLUMBING REQUIREMENTS 

Apply only joint compounds that are resistant to all gasses on all male pipe fittings.  Make sure to tighten every joint securely.  

DO NOT use pipe joint compound to connect flare fittings

.

Summary of Contents for CASUAL FIRESIDE 51-109

Page 1: ...ge BUILDING CODE AND FIXED PIPING SUPPLY REQUIREMENTS When an appliance is connected to a fixed gas piping supply system the installation must conform to local building codes or in the absence of local building codes to the National Fuel Gas Code ANSI Z223 1 NFPA 54 International Fuel Gas Code Natural Gas and Propane Installation Code CSA B149 1 or Propane Storage and Handling Code B149 2 as appli...

Page 2: ...G CODES TO DETERMINE IF THE OUTDOOR FIRE PIT IS PERMITTED IN YOUR LOCALITY BEFORE INSTALLATION FOR OUTDOOR USE ONLY THIS UNIT MUST BE INSTALLED AT LEAST 60 FROM CENTER OF BURNER TO ANY COMBUSTIBLE WALLS CEILINGS OR MATERIAL WHEN SHUTTING OFF THE UNIT BE SURE TO TURN THE CONTROL VALVE ON THE FIRE PIT TO THE FULLY OFF POSITION ON THE FIRE PIT and CLOSE THE VALVE ON THE PROPANE TANK or NATURAL GAS SU...

Page 3: ...may not be the same that your fire pit was setup for or is stated on your outdoor rating plate THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE GAS If the gas supply is different or you wish to change to Natural Gas you MUST have the Fire Pit Converted directions to convert can be found on page 12 to the gas type you intend to use Any gas type conversion should be performed by a qualified profess...

Page 4: ... into your Fire Pit WARNING DO NOT leave in operation when unattended H DO NOT use this appliance if any part of it has been under water Call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control part which has been under water before using The appliance should be inspected before use and at least annually by a qualified licensed ...

Page 5: ...st be provided with a listed overfilling prevention device and with a cylinder connection device compatible with the connection for the appliance 6 The LP Gas Cylinder must be standing on the designed bottom base of the cylinder for proper vapor withdrawal Occasional Height Fire Pits Propane Tank Options 11 Pound Tank 20 Pound Horizontal Tank Turn on the gas to the burner system and test for leaks...

Page 6: ...Kit Size 3 3 8 9 12 mm 13 Ceramic Rock Kit with Lava Granules 14 Mirrored Glass Kit Size 1 4 6 35mm LAVA GRANULES PLACEMENT CAUTION BURN HAZARD LAVA GRANULES WILL REMAIN HOT FOR SOME TIME AFTER USE YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUAT...

Page 7: ...tures Figure 3 Pour the second bag of media onto the burner support Taper from the top of the burner towards the width edge Figure 1 Rectangle Burner Support and Stainless Steel Burner Figure 2 Pour the first bag of the glass media into the burner support Page 7 GEM MIRRIORED AND TUMBLED GLASS MEDIA PLACEMENT GEM MIRRIORED AND TUMBLED GLASS MEDIA PLACEMENT Carefully inspect the carton for shipping...

Page 8: ...E PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING Note Lava granules used in a fire pit when heated up to normal operating temperatures can cause trapped gasses or moisture in the porous stone to expand and may pop and launch outside of the fire pit which could c...

Page 9: ... on Converting Your Fire Pit to a Different Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctly when finished for proper fire pit operation and safety This is a common problem when the fire pit has not been used for an extended period of time Low or Excessi...

Page 10: ...ructions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor fire pit burner found to be defective during this warranty period Regular maintenance must be exercised as set forth in the owner s manual For more information go to www owlee com Items Not Cover...

Page 11: ...ve layout This will help you to be confident operating the Fire Pit when fully installed see figures below for typical control positions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE BEFORE LIGHTING smell all around the Outdoor Fire Pit area for gas A rotten egg sme...

Page 12: ...he smaller orifice 4 If you are converting from propane LP gas to natural gas install the air shutter sleeve so that the air intake holes are closed Figure 2 For Propane gas remove the air shutter so that the air intake holes are open Figure 1 After the unit is assembled for use it is requires a leak check test on all connections are before placing the unit in operation 5 IT IS NECESSARY TO ATTACH...

Page 13: ...TTENTION Ne pas ranger ni employer d essence ou autres vapeurs et liquides inflammables près de cet appareil ou de tout autre appareil ménager Une bouteille basse pression non raccordée pour son emploi ne doit pas être rangée à proximité 1576mm 60 po de cet appareil ou de tout autre appareil ménager Cet appareil est conçu en tant qu appareil à surveiller Des adultes doivent être présents quand l a...

Page 14: ...TRUCTION POUR DETERMINER SI LE FOYER EXTÉRIEUR EN ADMET VOTRE LOCALITÉ AVANT L INSTALLATION POUR USAGE EXTÉRIEUR SEULEMENT CET APPAREIL DOIT ÊTRE INSTALLÉ AU MOINS 60 DE CENTRE DE BRÛLEUR À TOUT COMBUSTIBLE MURS PLAFONDS OU MATERIEL QUAND COUPER L UNITÉ METTEZ LA COMMANDE DE SOUPAPE SUR LE PIT INCENDIE À LA POSITION ENTIÈREMENT A L PIT FIRE ET FERMER LA ABANNE SUR LE RÈSERVIOR DE PROPANE ou GAZ NA...

Page 15: ...AZ EST INFÉRIEURE AU MINIMUM EXIGÉ OU DÉPASSE LE MAXIMUM E POUR LE GAZ NATUREL La pression minimale d admission du gaz pour les besoins de l ajustement de l entrée est de 88 9 mm 3 5 pouces de colonne d eau WC Water Column et la pression maximale d admission est de 266 7 mm 10 5 pouces WC POUR LE PROPANE La pression minimale d admission du gaz pour les besoins de l ajustement de l entrée est de 20...

Page 16: ...é au besoin afin de maintenir le fonctionnement et la flamme correcte en toute sécurité la hauteur et la coloration Page 4 L M Q P Le brûleur doit être remplacé avant de l appareil étant mis en service s il est évident que le brûleur est endommagé Remplacement brûleur COM0580 fabriqué par O W Lee Company 1822 E Francis Street Ontario CA 91761 R S INFORMATIONS IMPORTANTES SUR LA SÉCURITÉ A B E J AV...

Page 17: ...s d un bouchon de valve installé bien serré et ne doivent pas être rangées dans un bâtiment un garage ni aucun autre endroit fermé 6 La bouteille utilisée doit comprendre un collier pour protéger sa valve 2 Les bouteilles à gaz basse pression à utiliser doivent être construites et marquées conformément aux spécifications du Ministère des Transports des É U D O T Department of Transportation pour c...

Page 18: ...ranules de lave nº 13 Granules de lave 9 mm 3 8 po nº 14 Caillou de Feu en Verre Fourbi Taille 3 3 4 1 2 9 19 mm nº 15 Miroir en verre Taille 1 4 6 35 mm POSE DES GRANULES DE LAVE ET DES CRISTAUX DE VERRE Verser le sac de granules de lave ou de cristaux de verre dans le foyer extérieur de sorte que le brûleur soit totalement recouvert Voir la liste des pièces ci dessus pour les articles approuvés ...

Page 19: ...yau de verre dégringolé médias de verre dans le Brasier extérieur de sorte que le brûleur est complètement recouverte Voir la Figure 1 2 et 3 Figure 1 Rectangle brûleur de soutien et En acier inoxydable Burner Figure 2 Verser le premier sac du support de verre dans le support de brûleur Figure 3 Verser le deuxième sac de médias sur le support de brûleur Taper du haut du brûleur vers le bord de lar...

Page 20: ... DISPOSITION TELLE QU ILLUSTRÉE AFIN D ASSURER LE BON FONCTIONNEMENT DU FOYER SI UN MATÉRIAU DOIT ÊTRE REPOSITIONNÉ POUR MAINTENIR UN ARRANGEMENT ADÉQUAT EMPLOYER DES GANTS RÉSISTANT À LA CHALEUR OU LAISSER LE MATÉRIAU EFROIDIR AVANT DE LE MANIPULER Remarque Granulés de lave utilisés dans un puits du feu lorsque chauffés à des températures normales de fonctionnement peuvent provoquer des gaz piégé...

Page 21: ...et l orifice Insérez un petit fil dans le venturi et orifices des trous pour dégager le passage libre des toiles d araignées ou d autres débris Assurez vous de tout remettre correctement lorsque vous avez terminé pour le fonctionnement du foyer adéquat et la sécurité Ceci est un problème commun lorsque le foyer n a pas été utilisé pendant une longue période de temps Flamme faible ou excessive Util...

Page 22: ... Parties Pit Fire O W Lee offre une garantie limitée de deux 2 ans sur tous les composants du brûleur en utilisation normale et appropriée entretien OW Lee sera à l usine de réparer ou de remplacer tout brûleur extérieur foyer trouvé défectueux pendant cette période de garantie Un entretien régulier doit être exercé selon dans le manuel du propriétaire Pour plus d informations consultez www owlee ...

Page 23: ... l emploi du foyer une fois installé voir les figures ci dessous pour les positions typiques du contrôle POUR VOTRE SÉCURITÉ LIRE AVANT D ALLUMER ATTENTION L INOBSERVATION DE CES INSTRUCTIONS À LA LETTRE POURRAIT ÊTRE LA CAUSE D UN INCENDIE OU D UNE EXPLOSITION ENTRAÎNANT DES DOMMAGES MATÉRIELS DES BLESSURES OU LA MORT AVANT DE FAIRE FONCTIONNER sentez autour de la zone foyer extérieur pour le gaz...

Page 24: ...ne GPL de gaz naturel installer le manchon de l obturateur d air de telle sorte que les orifices d admission d air sont fermées Figure 2 Pour le gaz propane retirez l obturateur d air de telle sorte que les orifices d admission d air sont ouverts Figure 1 Après que l appareil est assemblé à l emploi il est besoin d un contrôle de fuite test sur toutes les connexions sont avant de placer l unité en...

Reviews: