PROBLEM

POSSIBLE CAUSE

SOLUTION

NOTES

Propane tank was not purged properly

Return the tank to an authorized propane station 
and re-purge the propane tank.

The Purge process requires that all air is removed 
from the propane tank prior to the first fill

The OPD float valve on the propane tank has 
been activated, closing the  valve and not 
allowing the tank to fill.

Attach the regulator to the propane tank, turn the 
control valve on for a few seconds to reset the 
OPD float valve.

The OPD float valve is a safety device which is 
activated when the propane tank has been filled 
too quickly.

Control valve not closed completely.

To shut off the valve, push the control valve in 
slightly to unlock and turn to the right (Clockwise) 
completely.

The far right position on the control valve is the 
off position

The regulator was not properly secured to the 
propane tank.

Disconnect the regulator and reconnect it properly 
to the propane tank.

The Regulator needs to be tightened securely & 
fully to the Propane Bottle to prevent propane 
leaks & to supply the correct amount of propane.

The tank was not purged properly, it contains a 
mixture of air and propane.  The results is 
intermittent flame, or flame extinguishes in a short 
period of time.

Burn off the remaining propane and re-purge the 
tank.

The purging process requires that ALL the air is 
removed from the propane tank during to the first 
fill to ensure maximum efficiency.  See your local 
authorized propane dealer.

In cooler temperatures, the liquid propane does 
not convert quickly enough to gas therefore 
causing the tank to freeze on the outside.

Turn the control valve to the low position where 
the flow is not a high.

Flame setting too low.

To Increase the flame, Turn the control valve 
clockwise to the 12 o'clock position to get the 
maximum amount of BTU's.

Flame setting too high.

To lower the flame, Turn the control valve counter 
clockwise from the 12 o'clock position a quarter 
turn to the set low position and a lower amount of 
BTU's.

Spiders may have created webs or insects may 
have created nests inside the venturi or orifice.

Make sure the fire pit is not is use & has not been 
used  recently and the unit is cold to the touch so 
as to not get burned.  Make sure the control valve 
is in the off position.  Close the propane tank valve 
or the fix piping supply line valve.  See page 12 of 
this manual on Converting Your Fire Pit to a 
Different Gas Type on how to access the venturi & 
the orifice.  Insert a small wire in the venturi & 
orifice holes to clear passage free of spider webs 
or other debris.  Make sure to put everything back 
correctly when finished for proper fire pit operation 
and safety.

This is a common problem when the fire pit has 
not been used for an extended period of time.

Low or Excessive Flame

Using Natural Gas

The water column may not have been adjusted 
correctly.

Contact your local licensed plumber or certified 
tech for assistance.

Fire Pit Wobbles

Cement slab or the use of natural stone may not 
be completely even.

Optional adjustable fire pit glides are available 
through your local dealer.

Optional glides are perfect for areas where the 
draining slope to level out a fire pit.

TROUBLE SHOOTING GUIDE

Propane Tank Does Not Fill

You Smell Propane or 

a Rotten Egg Smell

Flame Problems:

No Flame

Intermittent Flame

Low Flame

ADDITIONAL CARE

DO NOT

 remove the glass wind guards until it has completely cooled, approximately 1/2 hour.  Check to be sure that all glass guard connector fittings have not come 

loose after the cooling process.

DO NOT 

 lift the glass wind guard until connector fittings hardware has been checked and is still secure to the glass guards.  Glass connectors may have become 

loose after use.  Make sure all glass connectors are secure after each use of the glass wind guard.

Clean

 glass wind guards only after completely cool to the touch, approximately 45 minutes after use, with water and white vinegar mix or commercially available 

streak-free glass cleaner and a soft cloth.  

DO NOT

 touch glass wind guard for 30-45 minutes following use.  

It will be hot.

Fire Pit Base - 

Rust seepage and or oxidation may occur in some crevices.  The area can be easily serviced by using a detail brush and or fine grit sandpaper.  Once 

the are is clear from rust seepage or oxidation, follow by wiping clean and applying touch-up to seal the crevice.  Contact your local dealer for the matching touch-up 
pen or aerosol.

Hammered Copper Tops -

  Using a stainless steel polish will help protect & keep the top looking nice.  Note: Always use coasters when setting drinks and or food on 

the top.  Spilling acidic drinks and food may discolor the hand applied patina.  Should the patina be removed with acidic elements, the area will darken over time.

Porcelain Table Tops

 - Clean with mild soap and water. Rinse with clean water to remove all soap residue.  Note: The grout is made from a durable outdoor epoxy 

which does not need to be sealed.  

Page 9

Summary of Contents for CASUAL FIRESIDE 51-08

Page 1: ...t is operating burning DO NOT leave this unit operating burning when unattended If this product is left operating burning unattended it may cause serious injury or property damage BUILDING CODE AND FIXED PIPING SUPPLY REQUIREMENTS When an appliance is connected to a fixed gas piping supply system the installation must conform to local building codes or in the absence of local building codes to the...

Page 2: ...AN CAUSE SERIOUS INJURY OR DEATH FROM FIRE BURNS EXPLOSIONS OR CARBON MONOXIDE POISONING Clearances to Combustible Construction Sidewalls 60 1 5 m from center of unit Figure 1 Ceiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc The dimensions shown in Figure 1 are MINIMUM CLEARANCES to maintain when you install this Outdoor Fire Pit THERE MUS...

Page 3: ...y not be the same that your fire pit was setup for or is stated on your outdoor rating plate THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE GAS If the gas supply is different or you wish to change to Natural Gas you MUST have the Fire Pit Converted directions to convert can be found on page 12 to the gas type you intend to use Any gas type conversion should be performed by a qualified professio...

Page 4: ... the fire pit top surrounding the flame and should stay away to avoid burns and clothing or long hair ignition DO NOT continue using your FIRE PIT if you smell any unusual odors or have headaches nausea or dizziness G WARNING DO NOT throw trash paper plastics or any other flammable materials into your Fire Pit WARNING DO NOT leave in operation when unattended H DO NOT use this appliance if any par...

Page 5: ... gas at the supply LP Gas Cylinder Valve The LP Gas Cylinder must be disconnected when the appliance is not in use 4 5 6 The LP Gas Cylinder must be standing on the designed bottom base of the cylinder for proper vapor withdrawal CONNECTING AN LP GAS CYLINDER PROPANE TANK TO THE FIRE PIT Page 5 B Minimum Clearance to Combustibles Page 2 IMPORTANT BEFORE PROCEEDING CAREFULLY READ ALL OF THE IMPORTA...

Page 6: ...ERIAL ADEQUATE TIME TO COOL BEFORE HANDLING Note Lava granules used in a fire pit when heated up to normal operating temperatures can cause trapped gasses or moisture in the porous stone to expand and cause a pop and launch outside of the fire pit which could cause damage or injury Caution should be exercised when heating up the fire pit with lava granules to normal operating temperatures REPLACEM...

Page 7: ...ng temperatures Figure 1 Place the largest log diagonally centered over the burner Figure 2 Place the larger three logs as desired using the largest log as the support Figure 3 Place the balance of the logs as desired Make sure to leave enough air flow CERAMIC LOG MEDIA PLACEMENT Pour the lava granules into the Outdoor Fire Pit so that the burner is completely covers the burner by 1 2 and spread e...

Page 8: ...S SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING Note Lava granules used in a fire pit when heated up to normal operating temperatures can cause trapped gasses or moisture in the porous stone to expand and may pop and launch outside of the fire p...

Page 9: ... on Converting Your Fire Pit to a Different Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctly when finished for proper fire pit operation and safety This is a common problem when the fire pit has not been used for an extended period of time Low or Excessi...

Page 10: ......

Page 11: ...ied professional service technician Force or attempted repair may result in fire or explosion DO NOT use this appliance if any part has been under water Immediately call a qualified professional service technician to inspect the Outdoor Fire Pit and to replace any part of the control system and any gas control that has been under water Push in the manual gas control knob slightly and turn clockwis...

Page 12: ...etach the flex line connector hose attached to the orifice holder Figure 1 and unscrew the orifice holder from the burner pipe Figures 1 and 2 40 3 Remove the orifice from the holder Figure 2 and replace it with the proper sized one for your gas requirement Propane requires the smaller orifice 4 5 IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO CLEARLY INDIC...

Page 13: ...l Gas Code Code national du gaz É U à ANSI Z223 1 NFPA 54 Code international du gaz L installation de gaz naturel et de propane codes CSA B149 1 ou propane entreposage et de manutention Code B149 2 le cas échéant En cas d odeur de gaz UN STANDARD MEILLEUR EN QUALITÉ ET ASPECT FOYER EXÉRIEUR MAGNIFIQUE ET SANS DANGER POUR LE GAZ PROPANE ET NATUREL Kit de conversion Nécessite CASUAL FIRESIDE BTU ÉVA...

Page 14: ... L UTILISATION DE VOTRE FEU EXTÉRIEUR PIT PEUT CAUSER DES BLESSURES GRAVES OU LA MORT DE FEU BURNS EXPLOSIONS OU AU MONOXYDE DE CARBONE INTOXICATION Parois 60 1 5 m du centre de l unité Figure 1 Plafond 60 1 5 m de haut de l unité au plafond ou faux Revêtement de sol 0 Peut être installé sur le pont la dalle le plancher etc Les dimensions indiquées dans la figure 1 sont MINIMUM DÉGAGEMENTS à maint...

Page 15: ...PRESSION MAXIMALE EST DÉPASSÉE F Le système de tuyauterie du gaz doit être dimensionné de sorte à fournir la pression minimale d admission au débit maximum BTU hr Une perte excessive de pression se produira si le tuyau est trop petit ou trop long G Casual Fireside foyers sont adaptés pour l installation à partir de 0 4500 m sans modification H Si le foyer extérieur est raccordé au gaz naturel sa v...

Page 16: ...oyer la roche de lave ou en verre morceaux avec de l eau et sécher soigneusement avant d allumer Retirez toutes les toiles d araignée à l intérieur de l unité Effectuez périodiquement un contrôle visuel de la flamme du brûleur pour vous assurer qu il n a pas beaucoup changé en hauteur ou la coloration depuis le dernier être utilisé Toute modification significative de la hauteur de la flamme ou de ...

Page 17: ...e LP bouteille de gaz doit être débranchée lorsque l appareil est inutilisé 4 5 6 Le cylindre de gaz propane doit être debout sur la base inférieure du cylindre conçu pour le retrait de vapeur appropriée RACCORDEMENT D UN LP BOUTEILLE DE GAZ PROPANE AU PIT FIRE Page 5 B Minimum Dégagements aux combustibles Page 2 IMPORTANT AVANT DE PROCEDER LIRE ATTENTIVEMENT TOUT LE IMPORTANT INFORMATIONS SUR LA ...

Page 18: ...al PIÈCES DE RECHANGE ET MÉDIAS SONT DISPONIBLES SUR VOTRE CONCESSIONNAIRE nº 1 Kit de brûleur rectangle en acier inoxydable nº 2 Régulateur avec tuyau nº 3 Bouton de contrôle On Off marche arrêt nº 4 Tuyau flexible nº 5 Valve de rechange en cuivre nº 6 Connecteur de bouteille de propane nº 7 Orifice nº 8 Kit de conversion de gaz propane en gaz naturel nº 9 Kit de conversion de gaz naturel en gaz ...

Page 19: ...s le Brasier extérieur de sorte que le brûleur est complètement recouverte Voir la Figure 1 2 et 3 Figure 1 Verser le premier sac du support de verre dans le support de brûleur Figure 2 Verser le deuxième sac de support sur le support de brûleur Spead les médias qui couvrent Evely le brûleur Bûches en céramique placement dans les médias Verser les granulés de lave dans le Foyer extérieur de sorte ...

Page 20: ...ET SPHERE placement dans les médias Rocher Placement céramique Voir la Figure 1 2 et 3 ATTENTION brûlures ROCK CÉRAMIQUE ET CHAMP MEDIA Restera chaud pendant un certain temps après l utilisation VOUS DEVEZ conserver la disposition comme indiqué pour assurer le bon fonctionnement de votre feu PIT SI VOUS nécessité de repositionner TOUT MATÉRIEL POUR MAINTENIR l aménagement utiliser la chaleur GANTS...

Page 21: ...et l orifice Insérez un petit fil dans le venturi et orifices des trous pour dégager le passage libre des toiles d araignées ou d autres débris Assurez vous de tout remettre correctement lorsque vous avez terminé pour le fonctionnement du foyer adéquat et la sécurité Ceci est un problème commun lorsque le foyer n a pas été utilisé pendant une longue période de temps Flamme faible ou excessive Util...

Page 22: ... Parties Pit Fire O W Lee offre une garantie limitée de deux 2 ans sur tous les composants du brûleur en utilisation normale et appropriée entretien OW Lee sera à l usine de réparer ou de remplacer tout brûleur extérieur foyer trouvé défectueux pendant cette période de garantie Un entretien régulier doit être exercé selon dans le manuel du propriétaire Pour plus d informations consultez www owlee ...

Page 23: ...nter une réparation peut entraîner un incendie ou une explosion NE PAS EMPLOYER cet appareil si une partie ou pièce s est trouvée sous l eau Appeler immédiatement un technicien professionnel et qualifié pour inspecter le foyer et remplacer le cas échéant des pièces du système de contrôle et de commande du gaz qui se sont trouvées sous l eau INSTRUCTIONS D ALLUMAGE STOP LIRE LES MESURES DE SÉCURITÉ...

Page 24: ...n fonctionnement 5 IL EST NÉCESSAIRE DE POSER L ÉTIQUETTE OU LA PLAQUE SIGNALÉTIQUE INCLUSE DANS LE KIT DE CONVERSION AFIN D INDIQUER CLAIREMENT LA CONVERSION FAITE SUR PLACE Nº de série FIGURE 1 FIGURE 2 RÉSERVÉ AU FABRICANT Contrôle de la qualité Date Ordre de travail Essai de feu Volet d air X Nº d orifice PRINC 40 BTU Évaluation LP 60 000 NG 60 000 Nº d orifice AUTRE 12 COM0590CK Casual Firesi...

Reviews: