Model VFF23NLM
Gas Type
Natural
Propane/LP
Input 10,000Btu/Hr
10,000Btu/Hr
Manifold Pressure
4.5" W.C.
10" W.C.
Max. Inlet Pressure
10.5" W.C.
14" W.C.
Min. Inlet Pressure
*
7" W.C.
11" W.C.
TO TURN OFF GAS
TO APPLIANCE
OPERATION
Continued
Shutting Off Fireplace
1. Turn control knob clockwise to the
OFF position.
2. Turn off all electric power to the appli-
ance (if applicable) if service is to be
performed.
3. Close equipment shutoff valve (see
Figure 14, page 15).
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under
Lighting
Instructions
, page 17.
2. With control knob pressed in, strike
match.Hold match to pilot until pilot lights.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 8
under
Lighting Instructions
, page 17.
SPECIFICATIONS
Figure 21 - Pilot
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
6. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, page 22. Also, contact a
qualifi ed service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 19.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 3
through 7.
8. Turn control knob counterclockwise
to desired heating level. The burner
should light. Set control knob to any heat
level between HI and LO.
9. To leave pilot lit and shut off burners only,
turn control knob clockwise to the
PILOT position.
18
* For purposes of input adjustment