Rejection rate test 

You can test the efficiency (mineral rejection rate) of the RO 
membrane as follows: 

 

Turn off the Feed Water Valve. 

 

Turn off the Tank valve. 

 

Release system pressure by opening the faucet valve over 
the sink. 

 

Turn on the Feed Water Valve. 

 

Slide the switch to the FEED position and hold the faucet 
open until the reading stabilizes. This is the feed water TDS. 

 

Slide the switch to the RO position and hold the faucet open 
until the reading stabilizes. This is the RO water TDS. 

 

Compute the mineral rejection rate = 1 – (RO water TDS / 
feed water TDS). 

 

Recording the mineral rejection rate over time shows the 
“health” of the RO membrane. This directly affects the 
amount of 000 TDS water produced by a set of DI filters. 

21.

 

The Mineral Mizer is now ready for use. To check the 
mineral content, slide the Water Quality Monitor’s 
switch to the 

FEED

 position. Turn the monitor on by 

pressing its ON/OFF switch. The display shows the 
water’s mineral content, expressed in ppm TDS. This 
number will normally be in the 000 - 002 range. If the 
number is higher than 004, allow the tank to fill until 
the display is consistently in the 000 – 002 range and 
then discard the water as before. This should take no 
more than a few minutes. It will take about 3 hours to 
fill the Tank, depending on local water pressure and 
temperature.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
22.

 

Call O-SO PURE at 800-676-7873 to register this equipment. Please provide the following 
information: 

 

serial #, 

 

practice name, 

 

doctor name, 

 

practice address, 

 

practice responsible party with phone & email info. 

 
 
 
 

 

Water Quality Monitor slide switch settings 

FEED

 - Displays the mineral content of the feed 

(tap) water. 

RO

 – Displays the mineral content of RO water. 

DI 

– Displays the mineral content of the DI 

water coming out of the red faucet or 
dispensing gun, destined for your boiled water 
applications. 

Summary of Contents for Mineral Mizer

Page 1: ...l rev 7 DWS SADI Question or comments Contact O SO Pure at 800 OSO PURE or support osopure com Copyright 2016 O SO Pure All rights reserved Page 1 of 16 MINERAL MIZER DEIONIZED WATER SYSTEM INSTALLATI...

Page 2: ...Inspection 5 Pay Attention to All Warnings 5 INSTALLATION GUIDE 6 Locate the Mineral Mizer 6 Connect the Mineral Mizer to plumbing 7 OPERATING THEORY 10 SERVICING YOUR MINERAL MIZER 10 Schedule 10 Fi...

Page 3: ...ded Introduction Congratulations on your purchase of the Mineral Mizer autoclave water system The Mineral Mizer produces deionized DI water from tap water allowing you to exit the boiled bottled disti...

Page 4: ...Take inventory of all items supplied to ensure none are missing The box should contain the following Mineral Mizer Head Filters Spanner Wrench Filter Housings Blue 3 8 Tube Feed Water Tube w Press Reg...

Page 5: ...he Tank is usually placed at the back and the Mineral Mizer is positioned on the right side of the cabinet providing maximum viewing exposure to the right center clear filter sumps If this is a Minera...

Page 6: ...alve on the cold water stub plumbing Reconnect the faucet s cold water tube to the top of the Angle Stop Valve Close the Angle Stop Valve and turn on the cold water supply checking for leaks 6 Install...

Page 7: ...responding dots on the bracket Hand tighten all the Filter Sumps so they are snug Do not use the provided filter wrench to tighten the filter Sumps unless absolutely necessary Place the Mineral Mizer...

Page 8: ...th faucets are all CLOSED This will create enough water pressure in the system to see if there are any possible leaks coming from system Tighten the Filter Sumps with the Sump Wrench if necessary Chec...

Page 9: ...DI filters 21 The Mineral Mizer is now ready for use To check the mineral content slide the Water Quality Monitor s switch to the FEED position Turn the monitor on by pressing its ON OFF switch The d...

Page 10: ...s are directly affected by the RO feed water pressure and temperature The life of the membrane is determined by measuring the decline in the membrane s rejection rate over time Sans this level of meas...

Page 11: ...lters Some possibilities include consumption by staff taking water for home use or new boiled water applications Changing Filters 1 Turn off the water supply by closing the Inline Valve on the Feed Wa...

Page 12: ...d Thoroughly wash hands with soap before beginning installation and or sanitization procedure If your hands come into contact with any unsanitary surface while performing this procedure or the install...

Page 13: ...NO WATER OR NOT ENOUGH WATER Feed water shut off Turn on feed water Storage tank valve shut off Open tank valve Plugged or crimped lines Remove blockage or crimp in lines Pre filter cartridge clogged...

Page 14: ...800 OSO PURE to arrange shipment IMPORTANT To ensure proper treatment of source water purchaser must replace all filters and the UV lamp if applicable as directed in this manual Failure to service thi...

Page 15: ...Mizer Owner s Manual rev 7 DWS SADI Question or comments Contact O SO Pure at 800 OSO PURE or support osopure com Copyright 2016 O SO Pure All rights reserved Page 15 of 16 this page intentionally lef...

Page 16: ...der Rebate will not be applied retroactively o Only one 1 certificate may be redeemed per eligible O So Pure water system Dealer o Dealer and dealer employees are not eligible for referral fee o When...

Reviews: