background image

PROBLEM 

CAUSE 

SOLUTiON

Bubbles in the outlet and

splattering

Water does not fully moisten

the outside of the body

Wait for a few days (even after 

cleaning) to allow the smear layer on 

the outside of the body to regenerate 

itself

Flow rate is too high

Reduce flow rate

Alternatively: Fully insert the body 

into the sump for a few days.

TORQ

®

 is uneven

Place TORQ

®

 on an even surface

Filter media is not being properly 

floated

Flow rate is too low

Increase flow rate

Pump is clogged

Clean the pump

Use of too much filter media

Reduce amount of filter media

(see table on page 12)

Filter media collects at the top filter 

sponge and clogs it

Flow rate is too high 

Reduce flow rate

Too much filter media is used

Reduce amount of filter media

(see table on page 12)

Filter media goes into sump

Filter media is too fine

Use a larger filter media

If necessary add filter floss to the 

lid (Fig. 6)

Flow rate is too high

Reduce flow rate

Use of too much filter media

Reduce the amount of filter media

(see table on page 12)

Lid or screen insert can only be pla-

ced on acryic tube with difficulty

Clamp effect too strong

Rub the silicone rings with Vaseline,

silicone grease or similar

13

EN

FAQ AND TROUBLE SHOOTING

Summary of Contents for TORQ Body 1.0

Page 1: ...TORQ Dock TORQ Body 0 75 1 0 2 0 TORQ system reactor for filter media INSTRUCTIONS...

Page 2: ...instructions and safety information carefully before you use the device CONTENTS SAFETY INFORMATION 3 WARRANTY 4 INSTALLATION AND OPERATION 6 RECOMMENDED MEDIA CAPACITIES AND TANK SIZES 12 FAQ AND TR...

Page 3: ...rent of no more than 30 mA Ask your electrician Unplug all devices submerged in the water prior to any contact with aquarium water This device is only approved for inside use and only for aquarium pur...

Page 4: ...with the device The device may not be disposed of in the standard household rubbish It must be professionally disposed WARRANTY The consumer receives for this product a 12 month warranty for material...

Page 5: ...tear parts e g rotor seals Improper handling and use including the use of products from other manufacturers Any kind of damages e g wires of electrical devices Technical changes and modifications to...

Page 6: ...Q Dock as plug and play model The pump has already been installed Nyos TORQ has been designed for in sump use The unit cannot be used outside the sump Put Nyos TORQ Dock in your sump Please ensure tha...

Page 7: ...lug is in the groove of the acrylic pipe Fig 2 The filter sponge for the lid should always be used For small grain filter media such as Nyos PHOSI EX we recommend that you leave the black filter spon...

Page 8: ...ne filter media is used 3 Add the filter media from the top Put the lid back on Filling with two filter media Body 1 0 and Body 2 0 only 1 Turn the body upside down and remove the screen insert both f...

Page 9: ...into the tube Push the filter sponge a few centimeters into the tube by using the separating screen Keep hold of the acrylic stick and insert the second filter media 4 Push the filter sponge with hole...

Page 10: ...position the flow rate is zero Plug in the pump By turning the body counter clockwise you can increase the flow rate The flow rate can be read from the scale at the bottom end of the body The filter m...

Page 11: ...ent at optimum use This requires a run in period of several days A smear layer is created on the outside of the body so that the water fully moistens the body Removal position Setting the flow rate Ti...

Page 12: ...l 240 gal 1 800 l 475 gal Zeolite Nyos ZEO Maxium capacity 750 ml 25 fl oz 1 000 ml 34 fl oz 2 000 ml 68 fl oz Tank size up to 300 l 80 gal 400 l 100 gal 800 l 200 gal Usage of two filter media Phosph...

Page 13: ...f too much filter media Reduce amount of filter media see table on page 12 Filter media collects at the top filter sponge and clogs it Flow rate is too high Reduce flow rate Too much filter media is u...

Page 14: ...g 6 Generally speaking however this is not necessary Reducion in pump performance At the time of delivery the pump is set to a maximum per formance of 1 000 l h 264 gph Should you use very little filt...

Page 15: ...h tap water There is no need to use detergents The grid of the pump should be cleaned regularly in order to ensure constant performance To do this please remove the pump from the dock The grid of the...

Page 16: ...r sponge without hole 70 Part No T BSP_2603 Filter sponge without hole 70 Part No T BSP_2603 Filter sponge without hole 100 Part No T BSP_2610 6 Separating screen with acrylic stick 70 Part No T BSP_2...

Page 17: ...17 EN TORQ Body 0 75 TORQ Body 2 0 TORQ Body 1 0 4 5 5 6 7 7 8 9 8 9 10 10 10 6 8 9 4 4 3 3 3 5 2 2 1 1 2 1 EXPLODED DRAWINGS TORQ BODIES...

Page 18: ...ler Part No T DSP_Imp 13 Shaft Part No T DSP_2740 14 Bearing Part No T DSP_2757 15 Pump housing with slider Part No T DSP_2764 16 Dock housing Part No T DSP_2771 17 Dock base plate Part No T DSP_2788...

Page 19: ...19 EN NOTES...

Page 20: ...nyos aquatics Manufactured by Nyos Aquatics GmbH Siemensstr 26 70825 Korntal Muenchingen Germany www nyos info info nyos info Patents pending in EU US and elsewhere TORQ is a protected trademark of Ny...

Reviews: