Nylex VITON 403101 Product Manual Download Page 6

Cleaning Instructions

Troubleshooting

Cleaning the pump assembly (cont.)

Pull out the inner part of the pump assembly (D) and cap. 

Clean all pump parts and seals with water (or a suitable cleaning agent).

Reassemble the hose (G) and pump assembly (D) in the reverse order.

5

6

7

*When assembling the pump ensure that the pump gaskets are seated
  properly after installation and are not squashed. 

4

Unscrew the bottom section of the pump assembly. Inspect and clean the 
pump O-ring. Install a new O-ring if necessary.

FAULT

POSSIBLE CAUSES

REMEDY

Pump does not 

provide pressure

Pump sprays 

with poor jet spray

Bottle is difficult to open 

Hose connections at the 

pump and sprayer handle are leaking

Tighten the hose connections 

at the pump and sprayer handle

Filter in trigger blocked

Clean the filter in the trigger handle

Pressure in the bottle is too low

Clean the bottle cap

Valve in the bottle cap blocked

Clean the bottle cap

Nozzle blocked

Clean the nozzle