Troubleshooting:  

To improve communication:  

 

Operate the device closer to the router / director 

 

Move a ZigBee router / range extender closer to the desired operating area 

 

Replace battery 

 

Technical Specifications:  

 

Model Number: NCZ-3201 

 

Battery Type: 3.0 V CR2032 Lithium coin cell 

 

RF Frequency: ZigBee channels 11-26, 2.405 - 2.48 GHz 

 

Operating Temperature: -10

o

C to 50

o

C (14

o

F to 122

o

F) 

 

Dimensions: 32mm x 56mm x 6mm 

 

Battery Replacement: 

 

Remove back cover to expose battery 

 

Replace with 3.0 volt CR2032 Lithium coin cell battery, noting the correct polarity of the battery 

 

Button Functionality (Generic Commands): 

Button 

Function 

Lock Button 

Unlock Button 

Star Button 

1 Tap 

ACE: Arm all zones 

(Endpoint 1) 

ACE: Disarm 

(Endpoint 1) 

ACE: Panic (Endpoint 

1) 

2 Taps 

ACE: Arm all zones 

(Endpoint 2) 

ACE: Disarm 

(Endpoint 2) 

ACE: Panic (Endpoint 

2) 

3 Taps 

ACE: Arm all zones 

(Endpoint 3) 

ACE: Disarm 

(Endpoint 3) 

ACE: Panic (Endpoint 

3) 

Press 

ACE: Arm all zones 

(Endpoint 4) 

ACE: Disarm 

(Endpoint 4) 

ACE: Panic (Endpoint 

4) 

Release 

ACE: Arm all zones 

(Endpoint 5) 

ACE: Disarm 

(Endpoint 5) 

ACE: Panic (Endpoint 

5) 

 

 

 

 

 

 

 

 

Summary of Contents for NCZ-3201

Page 1: ...it power wireless ZigBee network for access control to other devices operating in a ZigBee Home Automation network Button functions network commands state change commands for other devices Accurate battery voltage level measurement and reporting back to co ordinator Network operation based on the ZigBee open profile Home Automation Up to 4 years projected battery life ...

Page 2: ...ent Remove back cover to expose battery Replace with 3 0 volt CR2032 Lithium coin cell battery noting the correct polarity of the battery Button Functionality Generic Commands Button Function Lock Button Unlock Button Star Button 1 Tap ACE Arm all zones Endpoint 1 ACE Disarm Endpoint 1 ACE Panic Endpoint 1 2 Taps ACE Arm all zones Endpoint 2 ACE Disarm Endpoint 2 ACE Panic Endpoint 2 3 Taps ACE Ar...

Page 3: ...ton 1 10 times Associated to the network Restore defaults leave network Press button 1 and button 2 together then Button 1 10 times Un associated to any network Restore defaults Press button 1 and button 2 together then Button 1 two times any Indicate network connectivity Press other than 1 2 4 6 10 times or other button combination any Single orange LED flash unsupported command The next press of...

Page 4: ...flashes Network leave or status not joined 3 slow Red flashes 1 second after other LED signalling is complete Low battery One Orange flashes Unsupported button command Two Orange Flashes Network Error Five Green flash Successfully reset to factory defaults All flashes are 250ms in duration Repeated flashes are each followed by a 250ms pause unless otherwise indicated A slow flash is 250ms in durat...

Page 5: ...r TV interference caused by unauthorized modifications to this equipment Such modifications could void the user s authority to operate the equipment Changes or modifications not expressly approved by NYCE Control Inc can void the user s authority to operate the equipment This device complies with Industry Canada license exempt RSS standard s Operation is Subject to the following two conditions 1 t...

Reviews: