POWER BRIDGE
POWER
REM
GND
+12V
FUSE
REMOTE
AUTO SENSING
ON
DSP NETLINK
IN
OUT
8
A
4 2 1
PRIMARY AMP
ADDRESS
MULTI-AMP
ADDRESS
OFF
HIGH
LEVEL
ON
OFF
SW
LEVEL
CONTROL
INPUT
LEVEL
MIN
MAX
INPUT
L
R
IN
OUT
PRT
MASTER
MODE
SLAVE
PWR
SPEAKER
NX1000.1
100A
P
OWER BRIDGE CONNECTIONS (OPTIONAL)
NXS’ Power Bridge technology gives you the flexibility to combine the power of two
NX1000.1 amplifiers or two NX2000.1 amplifiers to double the output power into one
speaker load.
The “Master” amplifier controls the level, crossover, equalization, subsonic filter for both the
master and slave amplifier.
IMPORTANT!
In Power Bridge operation, both amplifiers must be the same model of equal
power.
POWER BRIDGE
POWER
REM
GND
+12V
FUSE
REMOTE
AUTO SENSING
ON
DSP NETLINK
IN
OUT
8
A
4 2 1
PRIMARY AMP
ADDRESS
MULTI-AMP
ADDRESS
OFF
HIGH
LEVEL
ON
OFF
SW
LEVEL
CONTROL
INPUT
LEVEL
MIN
MAX
INPUT
L
R
IN
OUT
PRT
MASTER
MODE
SLAVE
PWR
SPEAKER
NX1000.1
100A
NX1000.1
+
+
-
-
NX1000.1
NXLCDC
LL
R
R
MASTER
MODE
SLAVE
MASTER
MODE
SLAVE
MODE IS SET TO “SLAVE”
POSITION
MODE IS SET TO
“MASTER” POSITION
2 Ohm Minimum
**CAUTION!
In the Power Bridge configuration the pair of NX1000.1’s or NX2000.1’s
must see
a 2 Ohm load or higher. Any lower than 2 Ohm will cause the amplifiers to overheat and possibly
cause permanent damage to the amplifiers!
18
E
N
G
L
IS
H
NX1000.1 & NX2000.1 CONNECTIONS