NXR 853265 Installation, Care And Maintenance Download Page 11

11

 

 

TESTING FOR LEAKS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GENERAL 

Although all gas connections on the grill are leak 

tested at the factory prior to shipment, a complete 

gas  tightness  check  must  be  performed  at  the 

installation  site  due  to  possible  mishandling  in 

shipment,  or  excessive  pressure  unknowingly 

being  applied  to  the  unit.  Periodically  check  the 

whole  system  for  leaks  following  the  procedures 

listed below. If the smell of gas is detected at any 

time  you  should  immediately  check  the  entire 

system for leaks. 

BEFORE TESTING 

Make  sure  that  all  packing  material  is  removed 

from the grill including the burner tie-down straps. 

DO NOT SMOKE WHILE TESTING FOR LEAKS. 

NEVER PERFORM LEAK TEST WITH AN OPEN 

FLAME. 

Make a soap solution of one part liquid detergent 

and  one  part  water.  You  will  need  a  spray  bottle, 

brush,  or  rag  to  apply  the  solution  to  the  fittings. 

For the initial leak test, make sure the L.P. cylinder 

is full. 

TO TEST   

1. Make sure the control valves are in the “OFF” 

position, and turn on the gas supply.   

2. Check all connections from the LP gas 

regulator and supply valve up to and including the 

connection to the manifold pipe assembly (the 

pipe that goes to the burners). Soap bubbles will 

appear where a leak is present.   

3. If a leak is present, immediately turn off the gas 

supply and tighten the leaky fittings.   

4. Turn the gas back on and recheck.   

5. Should the gas continue to leak from any of the 

fittings, turn off the gas supply and contact 

customer service at 1-888-909-8818, 9 a.m.-5 

p.m., PST, Monday-Friday. English, French, and 

Spanish representatives are available. 

Only  those  parts  included  by  the  manufacturer 

should be used on the grill.   

Substitution  will  void  the  warranty.  Do  not  use  the 

grill until all connections have been checked and do 

not leak. 

GAS FLOW CHECK 

Each grill burner is tested and adjusted at the factory 

prior  to  shipment;  however,  variations  in  the  local 

gas  supply  may  make  it  necessary  to  adjust  the 

burners.  The  flames  of  the  burners  should  be 

visually checked. 

Flames  should  be  blue  and  stable  with  no  yellow 

tips,  excessive  noise  or  lifting.  If  any  of  these 

conditions  exist,  check  to  see  if  the  air  shutter  or 

burner ports are blocked by dirt, debris, spider webs, 

etc. 

If  you  have  any  questions  regarding  flame  stability, 

please  call  customer  service  at  1-888-909-8818,  9 

a.m.-5p.m.,  PST,  Monday-Friday.  English,  French, 

and Spanish representatives are available.

 

ALWAYS  CHECK  FOR  LEAKS  AFTER 

EVERY L.P. TANK CHANGE 

Check  all  gas  supply  fittings  for  leaks 

before  each  use.  It  is  handy  to  keep  a 

spray  bottle  of  soapy  water  near  the 

shut-off  valve  of  the  gas  supply  line. 

Spray  all  the  fittings.  Bubbles  indicate 

leaks. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CSA requires the conversion must be performed by a qualified installer or gas supplier in

accordance with the manufacturer

jurisdiction. Failure to follow ALL instructions could result in serious injury or property damage. The

qualified agency performing this work assumes ALL responsibility and liability for this conversion.

Warning:

s

'  instructions and all codes and requirements of the authority having

Summary of Contents for 853265

Page 1: ...unattended Keep young children and pets away Do not move the device during use Not intended to be installed in or on boats and should never be used as a heater Close the valve of the gas cylinder afte...

Page 2: ...If odor continues keep away from the appliance and immediately call your gas supplier or your fire department Failure to follow these instructions could result in fire or explosion which could cause p...

Page 3: ...RRODE OR LIGHT THE EQUIPMENT ON FIRE DO NOT USE THE GRILL FOR COOKING EXCESSIVELY FATTY MEATS OR PRODUCTS WHICH CAN CAUSE FLARE UPS DO NOT OPERATE THE GRILL UNDER UNPROTECTED COMBUSTIBLE CONSTRUCTION...

Page 4: ...his manual The regulator and hose assembly must be inspected before each use of the grill If there is excessive abrasion or wear or if the hose is cut it must be replaced prior to the grill being put...

Page 5: ...o further than 61 cm 24 inches from the grill 3 Failure to follow these instructions could cause the propane tank to overheat and vent propane which could ignite causing serious personal juries or pro...

Page 6: ...art is missing or damaged do not attempt to assemble the product Contact customer service for replacement parts Estimated Assembly Time 10 minutes Tools Required for Assembly Phillips Screwdriver not...

Page 7: ...nt 2 05 Main Lid 1 18 Main Burner 2 06 Lid handle Insulating Spacer 2 19 Grease Tray 1 07 Lid Handle 1 20 Regulator and Hose 1 08 Main Firebox 1 21 Foot Stand Leg Right 1 09 Gas Valve 2 22 Lightning R...

Page 8: ...8 Fig2 Install the foot stand legs as shown below Fig1 ASSEMBLY INSTRUCTIONS Remove all the packing materials and move grill colse to a desired location...

Page 9: ...ay under the firebox as shown below Note When not in use please place the regulator on grill handle This will protect the regulator Fig4 Install the flame tamers on the burners then install the grid o...

Page 10: ...out of the reach of children It must NOT be stored in a building garage or any other enclosed area Cylinder s used must include a collar to protect the cylinder valve The specific size and capacity o...

Page 11: ...ly and contact customer service at 1 888 909 8818 9 a m 5 p m PST Monday Friday English French and Spanish representatives are available Only those parts included by the manufacturer should be used on...

Page 12: ...8 Natural Gas and Propane Installation Code CSA B149 1 or Propane Storage and Handing Code B149 2 or the standard for Recreational Vehicles 3 This outdoor cooking gas appliance is not intended to be i...

Page 13: ...replaced prior to use Connect the regulator onto the cylinder and leak check the hose and regulator connections before operating the grill Only the pressure regulator and hose assembly supplied with t...

Page 14: ...a fire causing death or serious injury may occur 1 If you have already attempted to light the main burner with the igniter allow 5 minutes for any accumulated gas to dissipate 2 Insert a match into t...

Page 15: ...repair or replacement shall be free of charge to you except for shipping costs as long as the purchaser is within the warranty period from the original date of purchase The original consumer purchaser...

Page 16: ...e abuse hostile environments inclement weather acts of nature animal tampering improper installation or installation not in accordance with local codes or printed manufacturer instructions THIS LIMITE...

Page 17: ...service department at 1 888 909 8818 9 a m 5 p m PST Monday Friday English French Spanish Send email to nxrcs duro global com AUSTRALIA Our goods come with guarantees that cannot be excluded under th...

Reviews: