NXP Semiconductors
AN12398
Quick start guide to SE050 Visual Studio projects
AN12398
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2019. All rights reserved.
Application note
Rev. 1.1 — 20 June 2019
534611
30 / 36
Figure 46. Open
PlugAndTrustMW.sln
Visual Studio project solution
3. The Visual Studio Community 2017 IDE will open with the SE050 Plug & Trust
middleware project examples included in the workspace as can be seen in
:
Figure 47.
PlugAndTrustMW.sln
Visual Studio project workspace
4. Change the VCOM port number in the SE050 Plug & Trust middleware project. To do
so, follow the instructions shown in
a. Go to the
ex_common
project and open the
ex_sss_ports.h
file inside the
headers
directory.
b. Change
#define EX_SSS_BOOT_SSS_COMPORT_DEFAULT "\\\\.\\COMx"
with the port COM number your laptop assigned to your FRDM-K64F. In this setup,
the COM number is COM9.