Chapter 28 Fault Collection Unit (FCU)
MPC5602P Microcontroller Reference Manual, Rev. 4
Freescale Semiconductor
781
Figure 28-17. Time switching protocol example
28.3.2.3
Bi-Stable protocol
In this protocol during the Init and the Fault state, faulty state is indicated. In the Normal/Alarm state,
non-faulty state is indicated.
shows bi-stable encoding for FCU[0].
Figure 28-18. Bi-stable coding example
Table 28-15. Bi-stable coding
Logical value
Bi-stable encoding
faulty
0
non-faulty
1
Reset
Configuration phase
Normal behavior
Error occurred
FCU[0]
During configuration phase
fake faults can be injected
so output may be different
Reset is asserted
Reset
Configuration phase
Normal behavior
Fault occurred
FCU[0]
During configuration phase
fake faults can be injected
so outputs may be different
Reset is asserted