UM10375
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2011. All rights reserved.
User manual
Rev. 3 — 14 June 2011
276 of 368
NXP Semiconductors
UM10375
Chapter 15: LPC13xx 16-bit timer/counters (CT16B0/1)
15.8.12 PWM Control register (TMR16B0PWMC and TMR16B1PWMC)
The PWM Control Register is used to configure the match outputs as PWM outputs. Each
match output can be independently set to perform either as PWM output or as match
output whose function is controlled by the External Match Register (EMR).
For timer 0, three single-edge controlled PWM outputs can be selected on the
CT16B0_MAT[2:0] outputs. For timer 1, two single-edged PWM outputs can be selected
on the CT16B1_Mat[1:0] outputs. One additional match register determines the PWM
cycle length. When a match occurs in any of the other match registers, the PWM output is
set to HIGH. The timer is reset by the match register that is configured to set the PWM
cycle length. When the timer is reset to zero, all currently HIGH match outputs configured
as PWM outputs are cleared.
Table 266. Count Control Register (TMR16B0CTCR - address 0x4000 C070 and
TMR16B1CTCR - address 0x4001 0070) bit description
Bit
Symbol
Value
Description
Reset
value
1:0
CTM
Counter/Timer Mode. This field selects which rising PCLK
edges can increment Timer’s Prescale Counter (PC), or clear
PC and increment Timer Counter (TC).
00
0x0
Timer Mode: every rising PCLK edge
0x1
Counter Mode: TC is incremented on rising edges on the
CAP input selected by bits 3:2.
0x2
Counter Mode: TC is incremented on falling edges on the
CAP input selected by bits 3:2.
0x3
Counter Mode: TC is incremented on both edges on the CAP
input selected by bits 3:2.
3:2
CIS
Count Input Select. In counter mode (when bits 1:0 in this
register are not 00), these bits select which CAP pin is
sampled for clocking.
Note:
If Counter mode is selected in
the CTCR register, bits 2:0 in the Capture Control Register
(CCR) must be programmed as 000.
00
0x0
CT16Bn_CAP0
0x1
Reserved.
0x2
Reserved.
0x0
Reserved.
31:4
-
-
Reserved, user software should not write ones to reserved
bits. The value read from a reserved bit is not defined.
NA
Table 267. PWM Control Register (TMR16B0PWMC - address 0x4000 C074 and
TMR16B1PWMC- address 0x4001 0074) bit description
Bit
Symbol
Value
Description
Reset
value
0
PWMEN0
PWM channel0 enable
0
0
CT16Bn_MAT0 is controlled by EM0.
1
PWM mode is enabled for CT16Bn_MAT0.