UM10462
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2016. All rights reserved.
User manual
Rev. 5.5 — 21 December 2016
316 of 523
NXP Semiconductors
UM10462
Chapter 14: LPC11U3x/2x/1x I2C-bus controller
Table 291. Slave Receiver mode
Status
Code
(STAT)
Status of the I
2
C-bus
and hardware
Application software response
Next action taken by I
2
C hardware
To/From DAT
To CON
STA STO SI
AA
0x60
Own SLA+W has
been received; ACK
has been returned.
No DAT action or
X
0
0
0
Data byte will be received and NOT ACK
will be returned.
No DAT action
X
0
0
1
Data byte will be received and ACK will
be returned.
0x68
Arbitration lost in
SLA+R/W as master;
Own SLA+W has
been received, ACK
returned.
No DAT action or
X
0
0
0
Data byte will be received and NOT ACK
will be returned.
No DAT action
X
0
0
1
Data byte will be received and ACK will
be returned.
0x70
General call address
(0x00) has been
received; ACK has
been returned.
No DAT action or
X
0
0
0
Data byte will be received and NOT ACK
will be returned.
No DAT action
X
0
0
1
Data byte will be received and ACK will
be returned.
0x78
Arbitration lost in
SLA+R/W as master;
General call address
has been received,
ACK has been
returned.
No DAT action or
X
0
0
0
Data byte will be received and NOT ACK
will be returned.
No DAT action
X
0
0
1
Data byte will be received and ACK will
be returned.
0x80
Previously addressed
with own SLV
address; DATA has
been received; ACK
has been returned.
Read data byte or
X
0
0
0
Data byte will be received and NOT ACK
will be returned.
Read data byte
X
0
0
1
Data byte will be received and ACK will
be returned.
0x88
Previously addressed
with own SLA; DATA
byte has been
received; NOT ACK
has been returned.
Read data byte or
0
0
0
0
Switched to not addressed SLV mode; no
recognition of own SLA or General call
address.
Read data byte or
0
0
0
1
Switched to not addressed SLV mode;
Own SLA will be recognized; General call
address will be recognized if
ADR[0] = logic 1.
Read data byte or
1
0
0
0
Switched to not addressed SLV mode; no
recognition of own SLA or General call
address. A START condition will be
transmitted when the bus becomes free.
Read data byte
1
0
0
1
Switched to not addressed SLV mode;
Own SLA will be recognized; General call
address will be recognized if
ADR[0] = logic 1. A START condition will
be transmitted when the bus becomes
free.
0x90
Previously addressed
with General Call;
DATA byte has been
received; ACK has
been returned.
Read data byte or
X
0
0
0
Data byte will be received and NOT ACK
will be returned.
Read data byte
X
0
0
1
Data byte will be received and ACK will
be returned.