6 Installing the software and setting up the hardware
6.1 Configuring the hardware
The FRDM-HB2000FEVM consists of an H-Bridge, a parallel and SPI interface, power
conditioning circuitry and an FRDM-KL25Z board. The board can be configured for use in
conjunction with a FRDM-KL25Z board or a function generator.
Caution
When using the FRDM-HB2000FEVM, make sure that the maximum motor supply voltage (VPWR) stays
within the 5.0 V to 40 V range. Operating outside this range may cause damage to the board.
6.1.1 Step-by-step instructions for setting up the hardware for use with a FRDM-
KL25Z
To configure the FRDM-HB2000FEVM for use with the FRDM-KL25Z do the following:
1. Connect the FRDM-HB2000FEVM to the FRDM-KL25Z using the Arduino
™
connectors on each board.
2. Connect the USB cable (not supplied with the kit) between the PC and the KL25Z
USB port on the FRDM-KL25Z board.
3. With the power switched off, attach the DC power supply to the VBAT and GND screw
connector terminal (J20) on the evaluation board.
4. Connect the load to the screw terminal (J21).
Figure 13
illustrates the hardware configuration using a FRDM-KL25Z.
FRDM-KL25Z Board
FRDM-HB2000FEVM
Brushed DC Motor
5 - 40 V Power Supply, 20 A
Workstation
Standard A to Mini-B
USB Cable
USB
Figure 13. FRDM-HB2000FEVM configured for use with an FRDM-KL25Z board