nVision Multi Chemistry High-End Charger
18
Precharge Time
When charging over-discharged batteries, the charger makes a slow charge before starting the fast
charge. This setting adjusts the duration of the slow charge. Slow charging over-discharged batteries
is recommended to avoid further damage to the batteries.
Precharge Time
OFF 1min
NiMH/NiCd delta-peak sensitivity
This setting adjusts the automatic delta-peak charge cut-off sensitivity. Use a higher value if the charge
tends to stop prematurely and a lower value if your battery is too hot at the end of the charge. Default
value is 7mV/cell for NiMh and 12mV/cell for NiCd.
NiMH Sensitivity
D.Peak Default
NiCd Sensitivity
D.Peak Default
Temperature monitoring
The connector on the left panel can be used to connect an optional temperature probe for battery
temperature monitoring. You can adjust the battery charge cut-off temperature.
Temp Cut-Off
ON 80C(176F)
Cycle delay
To prevent battery overheating during cycling, the charger can make a pause between the charge/
discharge cycles.
Wait Time
CHG >DCHG 5min
Summary of Contents for Multi Chemistry 4x50W
Page 1: ......
Page 3: ...www nvisionweb net 3 Backlit LCD Keypad Balancing connector Output connector 50W AC DC Charger...
Page 5: ...www nvisionweb net 5 Backlit LCD Keypad Balancing connector Output connector 80W AC DC Charger...
Page 78: ...nVision Multi Chemistry High End Charger 78 R C LiPo LiFe NiCd NiMH 2 LiPo LiFe AC DC...
Page 79: ...www nvisionweb net 79...
Page 80: ...www nvisionweb net Copyright 2014 nVision A trademark of Neidhart SA Switzerland...