nVent SCHROFF 10130-325 User Manual Download Page 28

 

 

 

Date: 2021/04/07 

Page

: 28 of 47

 

   

 

Screen Upgrade 

 

 

 

 

 

Summary of Contents for 10130-325

Page 1: ...1 nVent SCHROFF Cooling Cabinet LHX User Manual Release 1 0 07 04 2021 Doc No 61130 210...

Page 2: ...ility or liability for any errors or inaccuracies that may appear in this document Except as permitted by such license no part of this publication may be reproduced stored in a retrieval system or tra...

Page 3: ...ontrol 11 3 Transport and assembly 12 3 1 Safety rules for transport and assembly 12 3 2 Unpacking 13 3 3 Placing the cabinet 14 3 3 1 Lifting the cabinet from the pallet 15 3 4 Commissioning 16 3 4 1...

Page 4: ...t 34 6 Optional water kit 35 6 1 Installing the water kit 36 7 Dismantling storage and disposal 37 7 1 Safety rules for dismantling storage and disposal 37 7 2 Dismantling 38 7 3 Storage 38 7 4 Dispos...

Page 5: ...use includes compliance with the terms and conditions for assembly disassembly commissioning operation and maintenance specified by the manufacturer 1 2 Safety instructions of the manufacturer 1 2 1 D...

Page 6: ...t description of the danger The signal word DANGER indicates an immediate danger Non observance will result in severe injuries or death WARNING Symbol Short description of the danger The signal word W...

Page 7: ...gulations must also be adhered to 1 4 3 Personal protective equipment WARNING Risk of injury due to insufficient personal protective equipment If you use the wrong protective equipment or no protectiv...

Page 8: ...the time of the compilation of this manual Part No Type Height Width Depth Rear door Display Gasket 10130 325 LHX 5 kW 2000 x 600 x 800 mm IP 10130 326 LHX 5 kW 2000 x 600 x 1000 mm x x EMC 10130 327...

Page 9: ...kW Cooling module 10 kW 1 Water outlet 4 Bleeding valve 2 Water inlet 5 Actuator water valve 3 Condensate drain 10 mm 6 Fused mains input IEC60320 C14 The cooling modules contain no user serviceable...

Page 10: ...is cooled down and then blown into the front area of the cabinet Inside the air water heat exchanger the heat energy of the warm air is transferred to the medium of water The air water heat exchanger...

Page 11: ...chanical control valve in the water circuit to regulate the flow of water through the heat exchanger as a function of the heat load The control variable is the data from the cold air temperature senso...

Page 12: ...cking the cabinet WARNING Risk of accidents due to insufficiently qualified personnel The installation may only be carried out by qualified personnel who are authorized to do so according to the valid...

Page 13: ...al and packaging Dispose of the transport and packaging material in an environmentally compliant manner and in accordance with the applicable local rules and regulations Leave the cabinet on the palle...

Page 14: ...transport and assembly the corresponding personal protective equipment must be worn The cabinet is top heavy and can tip over At least 2 people are required when moving and unpacking the cabinet ATTE...

Page 15: ...net is fixed on the pallet Note For 800 mm deep cabinets the fan trays must be removed first 2 Remove the frontpanels and sidepanels 3 Adjust the forks to the cabinet width 4 Lift the cabinet carefull...

Page 16: ...ling of the system ATTENTION Damage due to condensation and spraying water The cabinet doors must be closed for operation If the cooling module is operated in an open cabinet condensation water will b...

Page 17: ...on the water connection The cooling infrastructure to which the unit is connected the external water loop must be appropriately dimensioned by the system designer taking into consideration the availab...

Page 18: ...al environment and the external recooling system and must be determined individually by the plant planner The following materials are used in the cooling module Aluminum Brass Copper Stainless steel T...

Page 19: ...ominal widths and the position of the connections at the cabinet s bottom plate can be found in the drawings in the appendix to this manual Condensate drain The bottom of the cooling module is designe...

Page 20: ...ngineer plumber open the water flow to the cabinet Connect a tube to the bleeding valve 1 and place it in a container with a capacity of at least 1 5 litres Open the actuator 2 manually with a 3 mm he...

Page 21: ...ical ratings label The voltage and current rating of the cable should be greater than the ratings marked on the product The cooling module must be operated with protective earth GND connection Use onl...

Page 22: ...at the top of the cabinet the other at the bottom at the cooling module To put the device into operation both inputs must be powered Power input cooling module 1 Fuse 2 Ground Stud M6 3 IEC60320 C14 c...

Page 23: ...ional flow and temperature sensor 8 Connector for remote display 4 Connector for cooling module fan control 9 RJ45 connector Ethernet 5 Connector for valve actuator 10 RJ45 connector RS485 Modbus RTU...

Page 24: ...be sealed off from the rear part of the cabinet by suitable air baffle plates and seals Make sure that power and water supply are connected and the doors are closed The cooling in the cabinet starts w...

Page 25: ...us RTU RS485 For this purpose the LHX controller can be connected to the nVent Schroff Guardian Management Gateway which natively supports the control of the LHX cooling module A list of Modbus regist...

Page 26: ...7 Screen Terminal Emulates the remote display In this screen all sensor data and operating parameters can be displayed and parameterized A description of the functions can be found in the chapter Disp...

Page 27: ...Date 2021 04 07 Page 27 of 47...

Page 28: ...Date 2021 04 07 Page 28 of 47 Screen Upgrade...

Page 29: ...Date 2021 04 07 Page 29 of 47 4 2 Display The display is mounted on the front door of the LHX 10130 326 327 cabinets and allows configuring the LHX controller or retrieve the operating parameters...

Page 30: ...2021 04 07 Page 30 of 47 4 2 1 Display Overview The temperature displayed depends on the operating mode of the temperature control In the example above it is the average of the cold air temperature se...

Page 31: ...Date 2021 04 07 Page 31 of 47 4 2 2 Display menu...

Page 32: ...rature of the lower cold bottom the upper cold top or the average value of these temperature sensors can be used In addition to the control via temperature sensors it is also possible to set the openi...

Page 33: ...parameters are available Average Air Temp Temp Air Bottom Temp Air Top Manual If a temperature sensor makes the control the temperature can be set in C F with manual control the opening ratio of the...

Page 34: ...replaced 5 1 Fan tray replacement ATTENTION The cooling module must be switched off before removing the fan If this is not done automatically e g by the door contact switch please unplug the power pl...

Page 35: ...ameters a water kit available as an accessory can be mounted The water kit is mounted in the water return and monitors water flow and return temperature If the water kit is retrofitted the controller...

Page 36: ...e carried out by a refrigeration engineer or suitably trained plumber Close the tap in the water supply Open the vent valve 1 Open the two union nuts 2 Remove the pipe 3 Mount the water kit with the g...

Page 37: ...inet WARNING Risk of accidents due to insufficiently qualified personnel The dismantling may only be carried out by qualified personnel who are authorized to do so according to the valid safety regula...

Page 38: ...supply and return under the cabinet floor collect the leaking water Close the water supply and return lines on the cabinet to prevent the water remaining in the heat exchanger from leaking out 7 3 St...

Page 39: ...AC 50 60 Hz 230 V AC 50 60 Hz 230 V AC 50 60 Hz Power consumption Controller 24 W Heat Exchanger 170 W Controller 24 W Heat Exchanger 170 W Controller 24 W Heat Exchanger 340 W Protection fuse Contro...

Page 40: ...SERIAL N CE FOR CABINET AND CONTROLLER 2x Part No 10130 326 Pos Designation Qty 1 VARISTAR EMC FRAME SL 2000x600x1000 mm H W D RAL7021 1x 2 VARISTAR EMC GASKET KIT 1x 3 BASE PLINTH H 100 mm 3 COVERS...

Page 41: ...8 SLIDE RAIL STD 600 mm 2PCS 1x 9 6 U HEAT EXCHANGER 10 kW 2 FANS 1x 10 2 WAY VALVE AND ACTUATOR 1x 11 WATER PIPEWORK INLET OUTLET WITH VENT VALVE G 3 4 CONE 60 1x 12 CONTROLLER BOX UNIT DIFF PRESSUR...

Page 42: ...07 Page 42 of 47 8 2 Spare parts Spare parts Part No Item 23130 666 Display 23130 667 Door Switch Kit 23130 668 Controller Box 23130 669 Actuator and ball valve 29714 026 Fan Tray LHX 5 29714 025 Fan...

Page 43: ...2021 04 07 Page 43 of 47 8 3 Accessoires Accessoires Part No Item 23130 660 LHX water hoses connection kit 1 5 m 23130 661 LHX water hoses connection kit 4 m 23130 663 Water flow and temperature senso...

Page 44: ...Date 2021 04 07 Page 44 of 47 23130 662 Water hoses duct for rear panel...

Page 45: ...Date 2021 04 07 Page 45 of 47 8 4 Cooling performance Cooling performance LHX 5 kW Cooling performance LHX 10 kW...

Page 46: ...Date 2021 04 07 Page 46 of 47 8 5 Air flow Air flow LHX 5 kW Air flow LHX 10 kW...

Page 47: ...Date 2021 04 07 Page 47 of 47 8 7 Noise Level Noise level LHX 5 kW Noise level LHX 10 kW...

Page 48: ...reserved in the event of the grant of a patent utility model or design L F B H size A1 last save 02 03 2021 print 02 03 2021 600 00 2113 00 822 50 A SIDE VIEW REAR VIEW TOP VIEW 117 05 B B FRONT VIEW...

Page 49: ...ent of the grant of a patent utility model or design L F B H size A1 last save 02 03 2021 print 02 03 2021 Tolerance Limits 600 00 2114 50 1600 00 A A BOTTOM VIEW TOP VIEW 999 60 1048 00 C SIDE VIEW R...

Page 50: ...Valve 0 10V CMD 1 2 3 M M1 1 5 W 90s 90 Top Top Bottom Bottom temp sensors Display temp sensors LHX10 2 Fans DOOR LHX10 2 Fans TECHN FLOOR X3 Differential pressure sensor 06 1 06 1 06 1 06 1 06 1 06 1...

Page 51: ...il as the communication of its DESSINER DRAWN DATE DATE 1 2 3 4 5 6 7 8 9 10 Sch ma lectrique F HARTMANN 06 19 03 20 72150 038 LHX10 2 Fans A E1124748 18 03 2020 8 Flow and T water sensor VFS Display...