PTB 20 ATEX 1008 U
II 2 G Ex eb mb IIC Gb
II 2 D Ex tb mb IIIC Db
IECEx PTB 20.0014U
Rated voltage:
nVent RAYCHEM JBM-100-E(P): 480 Vac**
JBM-100-L-E(P): 254 Vac
Ambient temperature: JBM-100-E(P): –55°C to +56°C**
JBM-100-L-E(P): –40°C to +40°C, except for VPL: in that case ambient
temperature can be up to +56°C.
**: Specific conditions for use may apply for ATEX.
Ex e(m) II T*
* For system Temperature Code, see heating cable or design documentation.
Rated voltage:
277 Vac
Ambient temperature: –40°C to +40°C
BR-EX e II
BR-Ex em II
Maximum pipe temperature:
Heater type
T
max
continuous
T
max
intermittent
1000h cumulative
T
max
power off
BTV
65°C
85°C
–
QTVR
110°C
110°C
–
XTV
121°C
250°C
–
KTV
150°C
250°C
–
VPL
See tables below
–
260°C
VPL: maximum pipe temperature in
dependence of heat type and voltage
VPL: Maximum pipe temperature
in dependence
Heater Type 230 Vac 254 Vac 277 Vac
≤ 150°C
≤ 180°C
≤ 230°C
5VPL2-CT
230°C
225°C
225°C
30 A
25 A
20 A
10VPL2-CT 210°C
200°C
195°C
30 A
25 A
20 A
15VPL2-CT 180°C
145°C
105°C
30 A
25 A
–
20VPL2-CT 150°C
Not allowed
30 A
–
–
Heater Type
385 Vac
400 Vac
480 Vac
≤ 150°C
≤ 180°C
≤ 230°C
5VPL4-CT
230°C
230°C
230°C
30 A
25 A
20 A
10VPL4-CT 215°C
215°C
205°C
30 A
25 A
20 A
15VPL4-CT 195°C
195°C
160°C
30 A
25 A
–
20VPL4-CT 150°C
150°C
150°C
30 A
–
–
Specific conditions for use using ATEX or IECEx approvals:
For ambient temperatures >+40°C:
Use a power cable with continuous temperature resistance of m90°C
Use a metallic power cable gland approved for use in hazardous areas
(for example GL-38-M25-METAL).
For voltages >254Vac and BTV, QTVR, XTV or KTV heating cables:
Use a power cable with continuous temperature resistance of m90°C
Use a metallic power cable gland approved for use in hazardous areas (for example GL-38-
M25-METAL).
For pipe temperature > 150°C and XTV or KTV heating cables, the maximum operating current
shall be reduced to maximum 20A.
JBM-100-E(P):
ТС RU C-BE.МЮ62.В.00054/18
Ex e IIC Gb U Ex tb IIIC Db U
Ex e mb IIC Gb U Ex tb mb IIIC Db U
Ta –55°C…+56°C IP66
ООО “ТехИмпорт”
JBM-100-L-E(P):
ТС RU C-BE.МЮ62.В.00054/18
Ex e IIC Gb U Ex tb IIIC Db U
Ex e mb IIC Gb U Ex tb mb IIIC Db U
Ta –55°C…+40°C IP66
ООО “ТехИмпорт”
Summary of Contents for JBM-100-A
Page 3: ...nVent com RAYCHEM 3 JBM 100 EP BTV QTVR XTV KTV VPL A B C...
Page 21: ...nVent com RAYCHEM 21 600 mm 600 mm 500 mm 600 mm 45 45 BTV QTVR XTV KTV VPL 1 1B...
Page 22: ...22 nVent com RAYCHEM 300 450 mm 90 2 1 5 mm BTV QTVR XTV KTV VPL BTV QTVR XTV KTV VPL 2 3...
Page 23: ...nVent com RAYCHEM 23 190 mm VPL 8 1 2 2 3 BTV QTVR XTV KTV VPL BTV QTVR XTV KTV 4 5...
Page 25: ...nVent com RAYCHEM 25 165 mm VPL VPL VPL 8 9 10...
Page 26: ...26 nVent com RAYCHEM 165 mm 40 mm 20 mm 1 2 2 3 1 2 1 VPL VPL VPL 11 12 13...
Page 27: ...nVent com RAYCHEM 27 15 mm 37 43 mm BTV QTVR XTV KTV VPL BTV QTVR XTV KTV VPL 14 15...
Page 29: ...nVent com RAYCHEM 29 BTV QTVR XTV KTV VPL BTV QTVR XTV KTV VPL 17 18 22 2Nm...
Page 30: ...30 nVent com RAYCHEM BTV QTVR XTV KTV VPL BTV QTVR XTV KTV VPL 19 20...
Page 31: ...nVent com RAYCHEM 31 BTV QTVR XTV KTV VPL 21...
Page 33: ...nVent com RAYCHEM 33 BTV QTVR XTV KTV VPL BTV QTVR XTV KTV VPL 24 25...
Page 34: ...34 nVent com RAYCHEM BTV QTVR XTV KTV VPL 26...
Page 37: ...nVent com RAYCHEM 37 50 50 20 40...
Page 38: ...38 nVent com RAYCHEM...
Page 39: ...nVent com RAYCHEM 39...