NVenergy Smart Thermostat Installation Manual Download Page 6

CHECK HVAC & TEST THERMOSTAT 

STEP 

Check that power is available to the thermostat 

The PowerShift thermostat display will show the date, time, HVAC mode, 
indoor temperature and setpoint if powered on.  Pressing any button will 
activate the screen. 
If power is not evident, check for the following: 

The Forced Air Unit/FAU breaker is turned back to the ON
position.  To reset the breaker if tripped, turn the breaker to
the OFF position, then back to the ON position 
Check that the correct 24VAC wires are connected to the 
RC/RH and C terminals 

Test the thermostat cooling mode 

To activate cooling mode on the PowerShift thermostat, turn to cooling mode by pressing Menu->Mode->Cool. 
On the home screen, press the down arrow until the cool setpoint is a few degrees lower than the indoor temperature. 
Wait for the system to turn on, which could take up to 5 minutes. 
Once the system is on, check any air vent for cool air coming out. 
Once cooling system is confirmed to be functioning, adjust to desired setpoint close to the indoor temperature. 
Your PowerShift thermostat will run on a default Cooling temperature program until you activate your account through the PowerShift portal. 

Menu

 

Select

 

Info

 

78

 

80 
COOL 

COOL 
FAN AUTO 
HOLD 

TUE  AUG  23 

10:45A 

CAUTION 

Important - DO NOT test cooling mode if outside temperature is below 50 degrees F. 

Test the thermostat heating mode 

To activate heating mode on the PowerShift thermostat, turn to heating mode by pressing Menu->Mode->Heat. 
On the home screen, press the up arrow until the heat setpoint is a few degrees higher than the indoor temperature. 
Wait for the system to turn on, which could take up to 5 minutes. 
Once the system is on, check any air vent for warm air coming out. 
Once heating system is confirmed to be functioning, adjust to desired setpoint close to the indoor temperature. 
Your PowerShift thermostat will run on a default Heating temperature program until you activate your account through the PowerShift portal. 

Page 6 

Summary of Contents for Smart Thermostat

Page 1: ...onal installation By selecting the self installation option it is the users responsibility to ensure that the thermostat is installed safely and properly NV Energy will not be liable for any damages caused by failure to comply with the installation instructions Screwdriver x 2 Volt Ohm Meter Labels 1 Standard Phillip head screwdriver included 1 Mini screwdriver 1 8 in 3mm Pencil Flashlight optiona...

Page 2: ...eadings of around 0V below 18 VAC means the Common Wire is not connected visit nvenergy com powershift selfinstallguide for additional instructions on how to connect the 24VAC Common Wire at the HVAC unit If you can t identify the Common Wire please visit nvenergy com powershift selfinstallguide for further instructions If you determine that the C X Wire is not connected and are not comfortable pr...

Page 3: ...e labels provided in box with the new PowerShift thermostat Identify and attach labels to each wire of your existing thermostat according to the terminal it is screwed into Make sure all your wires labeled before proceeding If you had to connect a new 24 VAC common wire you will use the C X label on that wire C X G C X Y Y2 G Y Y2 W W2 E W3 0 B RC RH W W2 E W3 0 B RC RH Disconnect and remove your ...

Page 4: ... exposed end of correct wires to matching screw terminals as labeled in Step 1 Tighten the terminal screw until each wire is secure enough to lightly pull on without coming loose Do not over tighten this may cut the wire IMPORTANT Menu Select Info RC RH W3 0 B W2 E W Y2 G L Y C X C X If you have just single R wire you can use either RH or RC terminal and leave the wire jumper clip in place If you ...

Page 5: ... connected to your Internet router to enable the PowerShift system to work properly A Connect the provided Ethernet cable between the gateway Ethernet port and any available port of your home router B Connect the provided 5VDC power supply between the gateway and a 120 VAC power source that will always stay powered on Startup sequence After plugging in the device the three LEDs at the top of gatew...

Page 6: ...k any air vent for cool air coming out Once cooling system is confirmed to be functioning adjust to desired setpoint close to the indoor temperature Your PowerShift thermostat will run on a default Cooling temperature program until you activate your account through the PowerShift portal Menu Select Info 7880 COOL COOL FAN AUTO HOLD TUE AUG 23 10 45A CAUTION Important DO NOT test cooling mode if ou...

Page 7: ...mperature schedules and program your thermostat Download mobile app for your smart phone to access your thermostat and adjust settings from anywhere Communicate with your thermostat by making adjustments to suit your comfort preferences the system will continually learn from the adjustments you make Watch your savings add up it may take up to one month for savings report data to appear in the port...

Page 8: ...tage cooling 1st stage heating 2nd stage heating 3rd stage heating 24VAC Power supply for Heating side 24VAC Power supply for Cooling side RC RH W3 0 B W2 E W Y2 G C X L Y Terminal Conventional Heat Cool system Heat Pump System 1st stage compressor 2nd stage compressor Auxiliary heating Emergency heating Changeover valve System monitor Fan Page 8 ...