background image

NuPower

TM

 ULS-25-C01-S01 User Manual    

 

 

 

Rev 1.0 

 

3

 

SETUP AND OPERATION 

This section provides specific details for proper operation of the NuPower ULS-25-C01-S01  module. 

Following these guidelines will prevent damage to the power amplifier or external equipment. 

3.1

 

POWER SUPPLY REQUIREMENTS 

To operate the NuPower ULS-25-C01-S01, ensure that the power supply has adequate overhead to source 

the current demand of the RF power amplifier. The power supply source must provide a typical voltage of 

+28 VDC with greater than 3 amps capability.  

3.2

 

CONNECTING A PROPER LOAD TO THE ANTENNA TERMINAL 

To prevent damage to the PA, the antenna terminal must be terminated into a 50 

Ω

 load. Examples of a 

proper load include: 
 

 

Directly connecting to an antenna specified for the frequency range (200  MHz to 2.6  GHz). 

Connecting to an inappropriate antenna may result in damage to the PA module.  

 

Connecting to a proper antenna through a 50 

Ω

 transmission line or coaxial cable. Avoid using 

damaged cables or corroded connectors while attaching the unit to an antenna. 

 

Terminating the antenna terminal into a 50 

Ω

 power attenuator with minimum 20 dB attenuation. 

 

Connecting to a load capable of dissipating the RF power from the PA module. Loads capable of 

handling 50 Watts (min) are recommended.  

3.3

 

POWERING-UP THE ULS-25-C01-S01 

The NuPower ULS-25-C01-S01 must be terminated to a proper load before power is applied. Refer to 

Section 3.2 for the specifications of the proper load. After the PA is properly terminated, the interface 

cable can be connected to the unit and power can be applied. The PA is now ready for operation.  

3.4

 

TRANSMIT TURN-ON TIME 

 

Caution: Do not apply transmit data until the PA module is at full power. This will prevent 

loss of data at the beginning of a message. 

 

The NuPower ULS-25-C01-S01 is at full power approximately 30 µS after the RF Enable line goes low 

(ground). Therefore, transmit data can be applied to the input after 30 µS without loss of data. 

3.5

 

RF OUTPUT POWER VS. SUPPLY VOLTAGE 

Although the NuPower ULS-25-C01-S01 was designed for +28 VDC operation, the module is capable of 

providing suitable RF power output over a broad range of supply voltages: +11 VDC to +32 VDC. 

Summary of Contents for NUPOWER ULS-25-C01-S01

Page 1: ...WERTM ULS 25 C01 S01 MINI MULTI OCTAVE POWER AMPLIFIER PART NUMBER NW PA ULS 25 C01 S01 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 FAX 1 800 376 2026 www nuwaves com sa...

Page 2: ...assis Completely Characterized The NuPower family of solid state power amplifiers has been completely characterized over temperature voltage and frequency These high performance modules offer signific...

Page 3: ...n systems The NuPower ULS 25 C01 S01 s rugged chassis allows the system integrator to easily incorporate the unit into a platform operating in harsh environments with limited space such as small Unman...

Page 4: ...ication Operating Temperature Ambient 40 to 60 o C Operating Temperature Baseplate 40 to 85 o C Storage Temperature 55 to 85 o C Table 3 NuPower ULS 25 C01 S01 Mean Time Between Failure MTBF Condition...

Page 5: ...L SPECIFICATIONS Figure 2 NuPower ULS 25 C01 S01 Mechanical Outline Table 4 NuPower ULS 25 C01 S01 Mechanical Specifications Parameter Specification RF Connectors SMA female Control Power Interface Co...

Page 6: ...AC DC adapter is shown with an example PA NuPower ULS 25 C01 S01 not shown Caution The use of external heat sinking is required especially for those applications requiring high duty cycle operation e...

Page 7: ...rroded connectors while attaching the unit to an antenna Terminating the antenna terminal into a 50 power attenuator with minimum 20 dB attenuation Connecting to a load capable of dissipating the RF p...

Page 8: ...ch operation Table 5 depicts the pin configurations to achieve low medium and high back off settings where N C is an indication to leave the pin floating i e not connected since the pin is tied high i...

Page 9: ...ion should always be loaded into 50 otherwise the PA could be damaged 4 1 INTERFACE CABLE HARNESS The cable harness that connects the host controller to the 9 pin Micro D connector of the NuPower ULS...

Page 10: ...ault to standby mode Grounding the pin i e a voltage below 0 2 VDC places the unit in transmit mode The user can either connect the RF Enable line to pins 1 2 on the CTRL PWR interface connector or an...

Page 11: ...isposing of a NuWaves product Do not remove the cover or any hardware Do not remove components from the circuit card assembly Do not incinerate Do not crush or shred Do not dispose of as unsorted muni...

Page 12: ...ng and Sales Phone 513 360 0800 Email sales nuwaves com NuWaves Home Page http www nuwaves com Product Warranty https products nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 6 1 GENERAL IN...

Reviews: