NuPower
TM
S100A01 User Manual
Rev 1.0
7
3.4
TRANSMIT TURN-ON TIME
The NuPower S100A01 is at full power approximately 500ns after the RF Enable line goes low (ground).
Therefore, transmit data can be applied to the input after 500ns without loss of data.
4
HARDWARE INTERFACE
•
The RF Input connector is SMA (female).
•
The RF Output connector is SMA (female).
•
The pin-out definitions for the Micro-D Hybrid, 7 +2-pin socket connector are provided in Table
5. In a typical installation, the PA module is mated to a host controller board via a cable harness.
The RF Out SMA connector is the antenna connection. This connection should
always be loaded into 50
Ω, otherwise the PA could be damaged.
4.1
INTERFACE CABLE HARNESS
The cable harness that connects the host controller to the Micro-D Hybrid, 7 +2-pin socket connector of
the NuPower S100A01 is made up of 9 wires.
Table 5: NuPower S100A01 Interface Pin-Out Definitions
Pin No.
Pin Name
I/0
Description
A2
DC Power
(+28V)
I
Primary Power (+28 VDC)
3, A1
GND
I
Signal and Power Ground
2
Over
Temperature
Flag
O
+5V TTL Logic Level
0V = Temperature Fault
+5V = No Fault
1
RF Enable
I
Transmit Control:
RF Enable Floating = RF Off
RF Enable Logic Low (0V- +0.8V) =
Bias Enabled
4
Current Temp
O
Analog voltage calibrated to
internal temp
5
N/C
N/A
No Connect