4.5

 

TEMP FLAG 

This signal is an output to indicate an over-temperature condition in the NuPower S100A01. A logic high 

(+5 VDC) indicates normal operation, while a logic low (0 VDC) indicates an over-temperature condition. 

The NuPower S100A01  incorporates internal logic circuitry that turns off the DC bias to the RF 

amplifiers. See section 4.6 for details on thermal shutdown points.  

 

 

 

Caution: The amplifier should be shut down and allowed to cool off when the over-

temperature flag is set low to avoid damage to the module. 
 
 
 
Do not connect the Temperature Flag to DC Power (+28 Volts input). The Temperature Flag 

can be used to monitor thermal status. 
 

4.6

 

CURRENT TEMP 

This signal is an output to indicate internal temperature of the S100A01. Temperature Flag (Section 4.5) 

threshold is reached when internal temperature of approximately 85°C is exceeded and will re-enable 

bias to internal RF amplifiers at approximately 70°C. See Figure 5 below for ‘current temp’ voltage and 

corresponding internal temperature. 

 

 

 

Figure 5. Current Temperature Output Voltage vs. Internal Temperature

 

 

200

250

300

350

400

450

500

550

600

650

700

750

800

850

900

950

1000

1050

1100

-40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85

Cu

rr

en

t T

emp

 V

ol

ta

ge (

mV

)

Internal Temperature (°C)

Current Temp Voltage vs. Internal Temperature

Current Temp (mV)

Summary of Contents for NUPOWER S100A01

Page 1: ...NUAL NUPOWERTM S100A01 S BAND POWER AMPLIFIER PART NUMBER NW PA S 100 A01 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 FAX 513 539 8782 www nuwaves com product sales nuwa...

Page 2: ...the chassis Completely Characterized The NuPower family of solid state power amplifiers have been completely characterized over temperature voltage and frequency These high performance modules offer s...

Page 3: ...ide GaN technology NuPower S Band power efficiency and 10 in3 cubic inch form factor make it ideal for size weight and power constrained broadband RF telemetry and tactical communication systems The N...

Page 4: ...2000 MHz 37 dBm 2250 MHz 41 dBm 2500 MHz RF Large Signal Gain 21 dB typ Input VSWR 1 5 1 typ Output Mismatch Max No Damage all Phase Angles 10 1 Nominal Input Drive Level 30 dBm Maximum Input Drive Le...

Page 5: ...ure 55 to 85 o C Table 2 Notes 145 C max ambient operating temperature with HTSK 07 Pout 100W 2 70 C max baseplate operating temperature S100A01 module only Pout 100W Table 3 NuPower S100A01 Mean Time...

Page 6: ...SPECIFICATIONS Figure 2 NuPower S100A01 Mechanical Outline Table 4 NuPower S100A01 Mechanical Specifications Parameter Specification RF Connectors SMA female Control Power Interface Connector Micro D...

Page 7: ...amplifier The power supply source must provide a typical voltage of 28 VDC with greater than 13 amps capability 3 2 CONNECTING A PROPER LOAD TO THE ANTENNA TERMINAL To prevent damage to the PA the an...

Page 8: ...harness The RF Out SMA connector is the antenna connection This connection should always be loaded into 50 otherwise the PA could be damaged 4 1 INTERFACE CABLE HARNESS The cable harness that connects...

Page 9: ...grounds are tied together in the PA module 4 4 RF ENABLE This signal is the logic control input that designates whether the unit is in transmit or standby mode The RF Enable line is pulled high intern...

Page 10: ...ure Flag to DC Power 28 Volts input The Temperature Flag can be used to monitor thermal status 4 6 CURRENT TEMP This signal is an output to indicate internal temperature of the S100A01 Temperature Fla...

Page 11: ...sing of a NuWaves product Do not remove the cover or any hardware Do not remove components from the circuit card assembly Do not incinerate Do not crush or shred Do not dispose of as unsorted municipa...

Page 12: ...d Sales Phone 513 360 0800 Email support nuwaves com NuWaves Home Page https www nuwaves com Product Warranty https products nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 6 1 GENERAL INFO...

Reviews: