NuPower
TM
15D05A-C01-S01 User Manual
Rev 1.0
7
3
SETUP AND OPERATION
This section provides specific details for proper operation of the NuPower 15D05A-C01-S01 module.
Following these guidelines will prevent damage to the power amplifier or external equipment.
3.1
POWER SUPPLY REQUIREMENTS
To operate the NuPower 15D05A-C01-S01, ensure that the power supply has adequate overhead to
source the current demand of the RF power amplifier. The power supply source must provide a typical
voltage of +28 VDC with greater than 6 amps capability.
3.2
CONNECTING A PROPER LOAD TO THE ANTENNA TERMINAL
To prevent damage to the PA, the antenna terminal must be terminated into a 50
Ω
load. Examples of a
proper load include:
•
Directly connecting to an antenna specified for the frequency range (800 MHz to 2500 MHz).
Connecting to an inappropriate antenna may result in damage to the PA module.
•
Connecting to a proper antenna through a 50
Ω
transmission line or coaxial cable. Avoid using
damaged cables or corroded connectors while attaching the unit to an antenna.
•
Terminating the antenna terminal into a 50
Ω
power attenuator with minimum 20 dB attenuation.
•
Connecting to a load capable of dissipating the RF power from the PA module. Loads capable of
handling 50 Watts (min) are recommended.
3.3
POWERING-UP THE NUPOWER 15D05A-C01-S01
The NuPower 15D05A-C01-S01 must be terminated to a proper load before power is applied. Refer to
Section 3.2 for the specifications of the proper load. After the PA is properly terminated, the interface
cable can be connected to the unit and power can be applied. The PA is now ready for operation.
3.4
TRANSMIT TURN-ON TIME
Caution: Do not apply transmit data until the PA module is at full power. This will prevent
loss of data at the beginning of a message.
The NuPower 15D05A-C01-S01 is at full power approximately 1 µS after the RF Enable line goes low
(ground). Therefore, transmit data can be applied to the input after 1 µS without loss of data.
3.5
RF OUTPUT POWER VS. SUPPLY VOLTAGE
The NuPower 15D05A-C01-S01 was designed for +28 VDC operation.