background image

NuPower

TM

 11B02A-TAC2 User Manual    

 

 

 

Rev 1.0 

 

4

 

HARDWARE INTERFACE 

 

 

The RF Input connector is TNC (female). 

 

The RF Output connector is N-type (female). 

 

The pin-out definitions for the 4 pin bayonet connector are provided in Table 5.  
 

 

The  RF  Out  N-type  connector  is  the  antenna  connection.  This  connection  should 
always be loaded into 50 

Ω

, otherwise the PA could be damaged. 

4.1

 

INTERFACE CABLE HARNESS    

The  cable  harness  that  connects  the  host  controller  to  the  4-pin  bayonet  connector  of  the  NuPower 
11B02A-TAC2 is made up of 4 wires.  

 

Table 5: NuPower 11B02A-TAC2 Interface Pin-Out Definitions 

Pin No. 

Pin Name 

I/0 

Description 

V Supply 

Primary Power (+28 VDC) 

GND 

Signal and Power Ground 

Temp Flag 

Temperature Flag (5V=no 

fault/0V=temp fault) 

RF Enable 

RF Enable 

(Floating=standby/GND=bias 

enable) 

 

 

Figure 4: Bayonet Connector Socket Locations 

Summary of Contents for NuPower 11B02A-TAC2

Page 1: ...1B02A TAC2 MINI MULTI OCTAVE POWER AMPLIFIER W INTEGRATED HEATSINK PART NUMBER NW PA 11B02A TAC2 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 FAX 513 539 8782 www nuwaves...

Page 2: ...d aluminum enclosure with mounting holes incorporated into the chassis Completely Characterized The NuPower family of solid state power amplifiers has been completely characterized over temperature vo...

Page 3: ...ation systems The NuPower 11B02A TAC2 s rugged IP67 rated chassis with integrated heat sink allows the system integrator or operator to easily incorporate the unit into a platform operating in harsh e...

Page 4: ...2 NuPower 11B02A TAC2 Environmental Specifications Operating Conditions Specification Operating Temperature Ambient 40 to 60 o C Operating Temperature Baseplate 40 to 85 o C Storage Temperature 55 to...

Page 5: ...ATIONS Figure 2 NuPower 11B02A TAC2 Mechanical Outline Table 4 NuPower 11B02A TAC2 Mechanical Specifications Parameter Specification RF Connectors Input Output TNC Female N Female Control Power Interf...

Page 6: ...go low 0VDC and bias to internal amplifiers will be removed until cooled to approximately 70 C Note If desired factory can reduce thermal shutdown point to protect users if worn on body Contact sales...

Page 7: ...id using damaged cables or corroded connectors while attaching the unit to an antenna Terminating the antenna terminal into a 50 power attenuator with minimum 20 dB attenuation Connecting to a load ca...

Page 8: ...2A TAC2 will be in standby mode Pulling the line low 0 5VDC to 1 5VDC or GND will place the module in transmit mode Note The RF Enable line is pulled high internally and does not require applying a vo...

Page 9: ...into 50 otherwise the PA could be damaged 4 1 INTERFACE CABLE HARNESS The cable harness that connects the host controller to the 4 pin bayonet connector of the NuPower 11B02A TAC2 is made up of 4 wir...

Page 10: ...isposal Improper disposal can adversely affect the environment wildlife and human health Please follow these guidelines when disposing of a NuWaves product Do not remove the cover or any hardware Do n...

Page 11: ...ing and Sales Phone 513 360 0800 Email sales nuwaves com NuWaves Home Page http www nuwaves com Product Warranty https products nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 6 1 GENERAL I...