background image

NuPower

TM

 11B02A-TAC2 User Manual    

 

 

 

Rev 1.0 

Maximum Input Drive Level 
(No damage) 

+10 dBm 

Power Amplifier Enable 

GND On 

Impedance 

50 

Ω

 

 
*The NuPower 11B02A-TAC2 will provide 10 watts (typ) RF output power across 200 MHz to 2.6 GHz 
with an input drive level of +3 dBm. 
 

Table 2: NuPower 11B02A-TAC2 Environmental Specifications 

Operating Conditions 

Specification 

Operating Temperature - 
Ambient 

-40 to +60 

o

Operating Temperature - 
Baseplate 

-40 to +85 

o

Storage Temperature 

-55 to +85 

o

 

Table 3: NuPower 11B02A-TAC2 Mean Time Between Failure (MTBF) 

Conditions 

Hours 

Ground Benign (GB) 

645,936 

Airborne Inhabited Cargo (AIC) 

217,065 

Airborne Inhabited Fighter (AIF) 

181,272  

Airborne Uninhabited Cargo (AUC) 

74,792 

Airborne Uninhabited Fighter (AUF) 

63,350 

 
 

 

Summary of Contents for NuPower 11B02A-TAC2

Page 1: ...1B02A TAC2 MINI MULTI OCTAVE POWER AMPLIFIER W INTEGRATED HEATSINK PART NUMBER NW PA 11B02A TAC2 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 FAX 513 539 8782 www nuwaves...

Page 2: ...d aluminum enclosure with mounting holes incorporated into the chassis Completely Characterized The NuPower family of solid state power amplifiers has been completely characterized over temperature vo...

Page 3: ...ation systems The NuPower 11B02A TAC2 s rugged IP67 rated chassis with integrated heat sink allows the system integrator or operator to easily incorporate the unit into a platform operating in harsh e...

Page 4: ...2 NuPower 11B02A TAC2 Environmental Specifications Operating Conditions Specification Operating Temperature Ambient 40 to 60 o C Operating Temperature Baseplate 40 to 85 o C Storage Temperature 55 to...

Page 5: ...ATIONS Figure 2 NuPower 11B02A TAC2 Mechanical Outline Table 4 NuPower 11B02A TAC2 Mechanical Specifications Parameter Specification RF Connectors Input Output TNC Female N Female Control Power Interf...

Page 6: ...go low 0VDC and bias to internal amplifiers will be removed until cooled to approximately 70 C Note If desired factory can reduce thermal shutdown point to protect users if worn on body Contact sales...

Page 7: ...id using damaged cables or corroded connectors while attaching the unit to an antenna Terminating the antenna terminal into a 50 power attenuator with minimum 20 dB attenuation Connecting to a load ca...

Page 8: ...2A TAC2 will be in standby mode Pulling the line low 0 5VDC to 1 5VDC or GND will place the module in transmit mode Note The RF Enable line is pulled high internally and does not require applying a vo...

Page 9: ...into 50 otherwise the PA could be damaged 4 1 INTERFACE CABLE HARNESS The cable harness that connects the host controller to the 4 pin bayonet connector of the NuPower 11B02A TAC2 is made up of 4 wir...

Page 10: ...isposal Improper disposal can adversely affect the environment wildlife and human health Please follow these guidelines when disposing of a NuWaves product Do not remove the cover or any hardware Do n...

Page 11: ...ing and Sales Phone 513 360 0800 Email sales nuwaves com NuWaves Home Page http www nuwaves com Product Warranty https products nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 6 1 GENERAL I...

Reviews: