HILNA HF w/ AGC User Manual
Rev ‐
4
2.2
HILNA HF ELECTRICAL DATA
Table 2: HILNA HF Absolute Maximum Rating
Operating Voltage
+30 VDC
RF P
in
+12 dBm
Operating Temperature
‐30 to + 70
0
C
Storage Temperature
‐40 to + 85
0
C
Table 3: HILNA HF DC Specifications
Unit
Min
Typ
Max
Operating Voltage
VDC
+12
+12
+30
Current Consumption
mA
150
300
Table 4: MGC Mode Specifications
Parameter
Unit
ATT A
ATT B
Attenuator Control Range
dB
0 to 31.5
0 to 31.5
Table 5: AGC Mode Specifications
Parameter
Unit
AGC Mode
Default Power Out
dBm
+2
Default Attack Time
mS
100
Default Decay Time
mS
100
AGC Output
dBm
‐5 (min), +10 (max)
Attack, Decay Time
mS
10 (min), 500 (max)